510(k) Report

510(k) · Cleared

Cleared

BriefCase-Triage

K242837510(k) SpecialCleared Oct 18, 202429-day reviewClass II21 CFR 892.2080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Aidoc Medical, Ltd. · QAS Radiological Computer-Assisted Triage And Notification Software

Cleared on Oct 18, 2024 as substantially equivalent to K203508 (Aidoc Medical, Ltd., 2020) after a 29-day review. Its family tree reaches back 5 generations to 2018.

Decided
Oct 18, 2024
Review
29 days
Class
Class II
Product code
QAS
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to DEN170073 (2018). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backDEN170073 ContaCTViz.Al, Inc. · 2018
  2. 4 generations backK180647 BriefCaseAidoc Medical, Ltd. · 2018
  3. 3 generations backK190072 BriefCaseAidoc Medical, Ltd. · 2019
  4. 2 generations backK201020 BriefCaseAidoc Medical, Ltd. · 2020
  5. 1 generation backK203508 BriefCaseAidoc Medical, Ltd. · 2020
  6. This deviceK242837 BriefCase-TriageAidoc Medical, Ltd. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5DEN170073ContaCTViz.Al, Inc.2018—
−4K180647BriefCaseAidoc Medical, Ltd.2018—
−3K190072BriefCaseAidoc Medical, Ltd.2019—
−2K201020BriefCaseAidoc Medical, Ltd.2020—
−1K203508BriefCaseAidoc Medical, Ltd.2020—
0 (this device)K242837BriefCase-TriageAidoc Medical, Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201920
202010
FIG. 1 — Lineage of K242837, 2018–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QAS device

  1. #1 K203508 BriefCasescore 25.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K203508BriefCase
Summary page 5
…device Regulatory Class: Class II Product Code: QAS Primary Predicate Device: BriefCase-Triage for CSF (K203508) Reference Device: BriefCase-Triage for PE (K241727) Device Description: BriefCase-Triage is a radiological compu…
Aidoc Medical, Ltd.2020—
†K241727BriefCase-TriageAidoc Medical, Ltd.2024—

Also cleared against K203508: 7 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 8 months on median.
  • None of the 8 ancestors has a recall.
  • 7 other devices also cite its predicate K203508.

How does its category compare?

All QAS devices

QAS Radiological Computer-Assisted Triage And Notification Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · QAS

15in 2025

2018: 32019: 52020: 122021: 52022: 152023: 112024: 122025: 152026 (partial year): 11
2007high 15 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QAS

101in 2025

2019: 111 days median2020: 112 days median2021: 86 days median2022: 116 days median2023: 98 days median2024: 136 days median2025: 101 days median2026 (partial year): 104 days median
2007high 136 (2024) · low 86 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QAS

No recall names QAS since 2007.

Adverse event reports per year · QAS

No MAUDE report names QAS since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20183—00
2019511100
20201211200
202158600
20221511600
2023119800
20241213600
20251510100
2026111040—

What is it indicated for?

BriefCase-Triage is a radiological computer aided triage and notification software indicated for use in the analysis of CT scans that include the cervical spine, in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of linear lucencies in the cervical spine bone in patterns compatible with fractures.…

Read the full statement (183 words)

BriefCase-Triage is a radiological computer aided triage and notification software indicated for use in

the analysis of CT scans that include the cervical spine, in adults or transitional adolescents aged 18

and older. The device is intended to assist hospital networks and appropriately trained medical

specialists in workflow triage by flagging and communication of linear lucencies in the cervical spine

bone in patterns compatible with fractures.

BriefCase-Triage uses an artificial intelligence algorithm to analyze images and highlight cases with

detected findings in parallel to the ongoing standard of care image interpretation. The user is

presented with notifications for cases with suspected findings. Notifications include compressed

preview images that are meant for informational purposes only and not intended for diagnostic use

beyond notification. The device does not alter the original medical image and is not intended to be

used as a diagnostic device.

The results of BriefCase-Triage are intended to be used in conjunction with other patient information

and based on their professional judgment, to assist with triage/prioritization of medical images.

Notified clinicians are responsible for viewing full images per the standard of care.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K242837: BriefCase-Triage.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K242837

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026