Sterilization Pouches and Reels

K242898510(k) TraditionalCleared Feb 21, 2025151-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shanghai Jianzhong Medical Packaging Co., Ltd. · FRG Wrap, Sterilization

Cleared on Feb 21, 2025 as substantially equivalent to K221875 (Qianjiang Kingphar Medical Packaging & Printing Co., Ltd., 2023) after a 151-day review. Its family tree reaches back 7 generations to 1999.

Decided
Feb 21, 2025
Review
151 days
Class
Class II
Product code
FRG
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K990567 (1999). No later device cites it as a predicate yet.

  1. Root · 7 generations backK990567 Global Healthcare Self-Sealing Sterilization PouchGlobal Healthcare, Inc. · 1999
  2. 6 generations backK993764 Medipack See-Through Seal Sterilization PouchMedipack Medical Packaging Mfg. Co. · 1999
  3. 5 generations backK051242 Winner Self Seal Sterilization PouchWinner Medical (Usa), Inc. · 2005
  4. 4 generations backK070428 Medicom Self-Sealing Sterilization PouchA.R. Medicom, Inc. · 2007
  5. 3 generations backK102158 Sigma Sterilization Pouch & RollSigma Medical Supplies Corp. · 2011
  6. 2 generations backK212338 SterileRight sterilization pouch and rollSterileright Packaging Mfg., Inc. · 2021
  7. 1 generation backK221875 Sterilization Pouch and RollQianjiang Kingphar Medical Packaging & Printing Co., Ltd. · 2023
  8. This deviceK242898 Sterilization Pouches and ReelsShanghai Jianzhong Medical Packaging Co., Ltd. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K990567Global Healthcare Self-Sealing Sterilization PouchGlobal Healthcare, Inc.1999—
−6K993764Medipack See-Through Seal Sterilization PouchMedipack Medical Packaging Mfg. Co.1999—
−5K051242Winner Self Seal Sterilization PouchWinner Medical (Usa), Inc.2005—
−4K070428Medicom Self-Sealing Sterilization PouchA.R. Medicom, Inc.2007—
−3K102158Sigma Sterilization Pouch & RollSigma Medical Supplies Corp.2011—
−2K212338SterileRight sterilization pouch and rollSterileright Packaging Mfg., Inc.2021—
−1K221875Sterilization Pouch and RollQianjiang Kingphar Medical Packaging & Printing Co., Ltd.2023—
0 (this device)K242898Sterilization Pouches and ReelsShanghai Jianzhong Medical Packaging Co., Ltd.2025—
FIG. 1 — Lineage of K242898, 1999–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRG device

  1. #1 K234050 HALYARD® ONE-STEP® Sterilization Wrap…score 15.8 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K221875Sterilization Pouch and Roll
Summary page 7
…Subsequent Product Code: JOJ; Regulation Number: 21 CFR 880.6850 Review Panel: General Hospital; 4. Identification of Predicate Device 510(k) Number: K221875 Product Name: Sterilization Pouch and Roll Regulation Number: 21 CFR 880.6850 Regulation Name: Sterilization Wrap…
Qianjiang Kingphar Medical Packaging & Printing Co., Ltd.2023—

Also cleared against K221875: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 8 companies; a new generation was cleared every 2.0 years on median.
  • None of the 7 ancestors has a recall.
  • 2 other devices also cite its predicate K221875.

How does its category compare?

All FRG devices

FRG Wrap, Sterilization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · FRG

9in 2025

2007: 32008: 22009: 42010: 42011: 62012: 102013: 62014: 82015: 122016: 92017: 92018: 52019: 92020: 52021: 42022: 92023: 92024: 112025: 92026 (partial year): 4
2007high 12 (2015) · low 2 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRG

151in 2025

2007: 182 days median2009: 171 days median2010: 213 days median2011: 110 days median2012: 133 days median2013: 146 days median2014: 177 days median2015: 196 days median2016: 131 days median2017: 260 days median2018: 150 days median2019: 258 days median2020: 122 days median2021: 170 days median2022: 217 days median2023: 230 days median2024: 182 days median2025: 151 days median2026 (partial year): 247 days median
2007high 260 (2017) · low 110 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRG

2in 2022

2013: 22017: 292020: 142022: 2
2007high 29 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRG

18in 2025

2007: 12008: 22009: 22011: 122012: 42013: 52014: 132015: 92016: 202017: 72018: 222019: 102020: 212021: 92022: 42023: 132024: 212025: 18
2007high 22 (2018) · low 0 (2010)2025

MAUDE reports naming product code FRG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007318201
20082—02
2009417102
2010421300
20116110012
20121013304
2013614625
20148177013
20151219609
20169131020
20179260297
20185150022
20199258010
202051221421
2021417009
2022921724
20239230013
202411182021
20259151018
202642470—

What is it indicated for?

The Sterilization Pouches and Reels is intended to provide health care workers with an effective method to enclosed devices in a single or double pouch configuration by steam or ethylene oxide sterilization. The recommended sterilization cycle parameters are as follows: a) Steam sterilization at 132°C (270°F) for 4 minutes; Drying time of 20 minutes. b) Ethylene Oxide (EO) with a concentration of 800 mg/L at 55 °C (131 °F) and 40%-80% relative humidity…

Read the full statement (238 words)

The Sterilization Pouches and Reels is intended to provide health care workers with an effective method to enclosed devices in a single or double pouch configuration by steam or ethylene oxide sterilization. The recommended sterilization cycle parameters are as follows:

a) Steam sterilization at 132°C (270°F) for 4 minutes; Drying time of 20 minutes.

b) Ethylene Oxide (EO) with a concentration of 800 mg/L at 55 °C (131 °F) and 40%-80% relative humidity for 6 hours. Aeration time of 7 days at 20°C (68 °F).

The Sterilization Pouches and Reels is composed of medical grade paper and medical compound film, maintains the sterility of the enclosed devices for up to 12 months post Steam or EO gas sterilization, and before sterilization has a maximum shelf life of 5 years from the date of manufacture. The pouch’s external chemical indicators are designed to indicate to the user that the pouch has undergone either a steam or EO Sterilization process. Sterilization indicators will change color according to the sterilization method (Steam, Ethylene oxide). The color of steam sterilization indicator changes from Pink before sterilization to Cocoa after sterilization. The color of Ethylene oxide sterilization indicator changes from Blue before sterilization to Golden Brown after sterilization. The maximum validated pouch load is 1.87 lbs. (850g); The maximum validated reel load is 1.87 lbs. (850 g)

The following tables (Table 1~5) identifies the size of subject device and its Maximum validated load.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K242898: Sterilization Pouches and Reels.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K242898

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026