NeuroEars-Anna™

K243709510(k) TraditionalCleared Aug 25, 2025266-day reviewClass II21 CFR 882.1460

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Neuroears, Inc. · GWN Nystagmograph

Cleared on Aug 25, 2025 as substantially equivalent to K143607 (Neuro Kinetics, Inc., 2015) after a 266-day review. Its family tree reaches back 2 generations to 2009.

Decided
Aug 25, 2025
Review
266 days
Class
Class II
Product code
GWN
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K083603 (2009). No later device cites it as a predicate yet.

  1. Root · 2 generations backK083603 I-Portal 4D Video Oculography Eye Tracking System (Vog), I-Portal…Neuro Kinetics · 2009 · Recalled
  2. 1 generation backK143607 I-Portal NOTC, VNG and VOGNeuro Kinetics, Inc. · 2015 · Recalled
  3. This deviceK243709 NeuroEars-Anna™Neuroears, Inc. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K083603I-Portal 4D Video Oculography Eye Tracking System (Vog), I-Portal Video…Neuro Kinetics20094
−1K143607I-Portal NOTC, VNG and VOGNeuro Kinetics, Inc.20151
0 (this device)K243709NeuroEars-Anna™Neuroears, Inc.2025—
FIG. 1 — Lineage of K243709, 2009–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWN device

  1. #1 K260566 SMARTVERTIGO™ Vestibular Assessment Systemscore 12.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143607I-Portal NOTC, VNG and VOG
Summary page 6
…acteristics • Vestibular Tests Predicate Device 510k Number Trade or Proprietary or Model Name Manufacturer Product Code K143607 I-Portal® Neuro Otologic Test Center Neuro Kinetics, Inc. GWN (NOTC) I-P…
Neuro Kinetics, Inc.20151

Also cleared against K143607: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 3 companies; a new generation was cleared every 10.1 years on median.
  • 2 of the 2 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K143607.

How does its category compare?

All GWN devices

GWN Nystagmograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · GWN

3in 2025

2007: 22008: 12009: 12013: 32015: 32016: 22017: 42018: 32019: 12020: 22023: 12025: 32026 (partial year): 1
2007high 4 (2017) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWN

203in 2025

2013: 88 days median2015: 165 days median2017: 160 days median2018: 87 days median2025: 203 days median
2007high 203 (2025) · low 87 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWN

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWN

1in 2025

2012: 22018: 12019: 52021: 12022: 12023: 32024: 42025: 1
2007high 5 (2019) · low 0 (2007)2025

MAUDE reports naming product code GWN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—00
20091—00
20100—00
20110—00
20120—02
201338810
20140—00
2015316500
20162—00
2017416000
201838701
20191—05
20202—00
20210—01
20220—01
20231—03
20240—04
2025320301
20261—0—

What is it indicated for?

The NeuroEars-Anna™ system provides information to assist in the nystagmographic evaluation, diagnosis, and documentation of vestibular disorders. Nystagmus of the eye is recorded using a head-mounted display equipped with eye-tracking cameras. These images are measured, recorded, displayed, and stored in the software. This information can then be used by trained medical professionals to assist in diagnosing vestibular disorders. The NeuroEars-Anna™…

Read the full statement (168 words)

The NeuroEars-Anna™ system provides information to assist in the nystagmographic evaluation, diagnosis, and documentation of vestibular disorders. Nystagmus of the eye is recorded using a head-mounted display equipped with eye-tracking cameras. These images are measured, recorded, displayed, and stored in the software. This information can then be used by trained medical professionals to assist in diagnosing vestibular disorders.

The NeuroEars-Anna™ system is intended for use in individuals aged 12 years and older, based on the physical compatibility of the FOVE VR headset (FOVE Inc., Japan). While the ANSI S3.45 standard does not define age-based limitations, the FOVE VR headset is generally suitable for individuals aged 12 and above. For improved fit, soft materials such as sponge pads may be used in cases where the headset does not conform properly to the user's face. This applies to both pediatric and adult patients. Any additional padding should be used only if it does not interfere with eye-tracking performance or measurement accuracy and must follow the manufacturer’s instructions for proper use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K243709: NeuroEars-Anna™.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K243709

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026