510(k) Report

510(k) · Cleared

Cleared

Laia XR

K251577510(k) TraditionalCleared Feb 6, 2026260-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Augmented Reality Software S.L. · LLZ System, Image Processing, Radiological

Cleared on Feb 6, 2026 as substantially equivalent to K213215 (Apoqlar GmbH, 2022) after a 260-day review. Its family tree reaches back 14 generations to 1991.

Decided
Feb 6, 2026
Review
260 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 14 generations to K913770 (1991). 55 ancestors in all, the oldest K896095 (1990). No later device cites it as a predicate yet.

  1. Root · 14 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 10 generations between
  3. 3 generations backK163232 Vitrea ViewVital Images, Inc. · 2017
  4. 2 generations backK190764 SurgicalARMedivis, Inc. · 2019
  5. 1 generation backK213215 VSI HoloMedicineApoqlar GmbH · 2022
  6. This deviceK251577 Laia XRAugmented Reality Software S.L. · 2026
Show all 14 generations
  1. Root · 14 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 13 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 12 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 11 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 10 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 9 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 8 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 7 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  9. 6 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  10. 5 generations backK071362 Vital Connect 4.1Vital Images, Inc. · 2007 · Recalled
  11. 4 generations backK150738 VitreaViewVital Images, Inc. · 2015
  12. 3 generations backK163232 Vitrea ViewVital Images, Inc. · 2017
  13. 2 generations backK190764 SurgicalARMedivis, Inc. · 2019
  14. 1 generation backK213215 VSI HoloMedicineApoqlar GmbH · 2022
  15. This deviceK251577 Laia XRAugmented Reality Software S.L. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−13K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−12K020483Advantage Workstation 4.1GE Medical Systems20022
−11K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−10K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−9K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−8K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−7K052632VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc.20052
−6K061624Vitrea, Version 3.9Vital Images, Inc.20061
−5K071362Vital Connect 4.1Vital Images, Inc.20073
−4K150738VitreaViewVital Images, Inc.2015—
−3K163232Vitrea ViewVital Images, Inc.2017—
−2K190764SurgicalARMedivis, Inc.2019—
−1K213215VSI HoloMedicineApoqlar GmbH2022—
0 (this device)K251577Laia XRAugmented Reality Software S.L.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199120
199430
199510
199640
199720
199840
199920
200030
200170
200230
200440
200510
200610
201010
201110
201210
FIG. 1 — Lineage of K251577, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K213215VSI HoloMedicine
Summary page 5
…processing system Regulation Number 892.2050 Product Code LLZ III) Predicate Device 510(k) Number K213215 Applicant apoQlar GmbH Trade Name VSI HoloMedicine® Classification…
Apoqlar GmbH2022—

Also cleared against K213215: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 35 years and passes through 7 companies; a new generation was cleared every 1.8 years on median.
  • 14 of the 55 ancestors have a recall of any class.
  • 1 other device also cites its predicate K213215.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

LAIA XR is a software device for displaying digital medical images, especially for CT and MR images (DICOM format). It is intended to visualize 3D medical imaging of the patient for pre-operative planning outside the surgical room.

When accessing LAIA XR from a wired head-mounted display (HMD) or PC monitor, images viewed are for informational purposes only and not intended for diagnostic use. LAIA XR is indicated for use by qualified healthcare professionals including surgeons, radiologists, physicians, and technologists.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K251577: Laia XR.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K251577

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026