Drägerwerk AG & Co. KGaA · FMZ Incubator, Neonatal
Cleared on Feb 13, 2026 as substantially equivalent to K182859 (Dragerwerk AG & CO Kgaa, 2019) after a 262-day review. Its family tree reaches back 3 generations to 2001.
- Decided
- Feb 13, 2026
- Review
- 262 days
- Class
- Class II
- Product code
- FMZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K010222 (2001). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FMZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FMZ device
- #1 K251663 Giraffe OmniBed Carestation (CS1); Giraffe…score 14.4 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K182859 | Babyleo TN500Summary page 5…5400 Product code: FMZ/FMT Class: II Predicate device: Babyleo TN500, K182859 Common name: Neonatal Incubator Classification name:… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 7.0 years on median.
- 1 of the 3 ancestors has a recall of any class.
How does its category compare?
All FMZ devicesFMZ Incubator, Neonatal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · FMZ
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FMZ
60in 2010
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FMZ
2in 2024
Class I (11 since 2007) Class II/III not classified
Adverse event reports per year · FMZ
250in 2025
MAUDE reports naming product code FMZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 81 | 0 | 14 |
| 2008 | 1 | — | 4 | 10 |
| 2009 | 0 | — | 0 | 8 |
| 2010 | 4 | 60 | 0 | 11 |
| 2011 | 1 | — | 5 | 10 |
| 2012 | 0 | — | 0 | 12 |
| 2013 | 0 | — | 1 (1) | 11 |
| 2014 | 1 | — | 0 | 3 |
| 2015 | 1 | — | 0 | 9 |
| 2016 | 1 | — | 1 | 12 |
| 2017 | 1 | — | 0 | 4 |
| 2018 | 2 | — | 3 | 18 |
| 2019 | 2 | — | 1 | 24 |
| 2020 | 0 | — | 0 | 8 |
| 2021 | 0 | — | 0 | 15 |
| 2022 | 1 | — | 0 | 27 |
| 2023 | 0 | — | 8 (8) | 19 |
| 2024 | 0 | — | 2 (2) | 118 |
| 2025 | 2 | — | 0 | 250 |
| 2026 | 2 | — | 3 | — |
What is it indicated for?
The Babyleo TN500 is intended for use with neonates and infants and can be used as both an incubator and a radiant warmer. When the product is switched between incubator and radiant warmer operation, patients continue to be kept warm during the transition. It enables the controlled warming of patients with a body weight of up to 10 kg (22 lbs). The device can be operated as either a closed care unit or an open care unit. As a closed care unit, Babyleo…
Read the full statement (146 words)
The Babyleo TN500 is intended for use with neonates and infants and can be used as both an incubator and a radiant warmer. When the product is switched between incubator and radiant warmer operation, patients continue to be kept warm during the transition. It enables the controlled warming of patients with a body weight of up to 10 kg (22 lbs). The device can be operated as either a closed care unit or an open care unit. As a closed care unit, Babyleo TN500 is an incubator. Neonates and infants are kept warm in the patient compartment with humidifiable air which can be enriched with oxygen (option). As an open care unit, Babyleo TN500 is a radiant warmer.
The Babyleo TN500 provides controlled ambient conditions for neonates and infants. The following parameters are regulated, according to the intended use:
– Temperature
– Humidity
– Oxygen (option)
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K251619 · printed Nov 6, 2026
Cite this page
510(k) Report. “K251619: Babyleo TN500.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K251619
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026