510(k) Report

510(k) · Cleared

Cleared

Ryurei

K252295510(k) TraditionalCleared Mar 27, 2026247-day reviewClass II21 CFR 870.5100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Terumo Corporation · LOX Catheters, Transluminal Coronary Angioplasty, Percutaneous

Cleared on Mar 27, 2026 as substantially equivalent to K180921 (Orbusneich Medical Trading, Inc., 2018) after a 247-day review. Its family tree reaches back 5 generations to 2004.

Decided
Mar 27, 2026
Review
247 days
Class
Class II
Product code
LOX
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K042537 (2004). 8 ancestors in all, the oldest K012913 (2001). No later device cites it as a predicate yet.

  1. Root · 5 generations backK042537 Submarine Plus Percutaneous Transluminal Angioplasty (Pta) Catheter…Invatec Innovative Technologies · 2004
  2. 4 generations backK072947 Savvy Long and Sleek Peripheral Transluminal Angioplasty (Pta)…ClearStream Technologies, Ltd. · 2008
  3. 3 generations backK100490 Litepac, Model 682ClearStream Technologies, Ltd. · 2010
  4. 2 generations backK131199 Ultraverse RX Pta Balloon Dilatation CatheterBard Peripheral Vascular, Inc. · 2013
  5. 1 generation backK180921 Sapphire II PRO Balloon Dilatation CatheterOrbusneich Medical Trading, Inc. · 2018
  6. This deviceK252295 RyureiTerumo Corporation · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K042537Submarine Plus Percutaneous Transluminal Angioplasty (Pta) Catheter, Model…Invatec Innovative Technologies2004—
−4K072947Savvy Long and Sleek Peripheral Transluminal Angioplasty (Pta) CathetersClearStream Technologies, Ltd.2008—
−3K100490Litepac, Model 682ClearStream Technologies, Ltd.2010—
−2K131199Ultraverse RX Pta Balloon Dilatation CatheterBard Peripheral Vascular, Inc.2013—
−1K180921Sapphire II PRO Balloon Dilatation CatheterOrbusneich Medical Trading, Inc.2018—
0 (this device)K252295RyureiTerumo Corporation2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
201010
201210
FIG. 1 — Lineage of K252295, 2004–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LOX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LOX device

  1. #1 K254022 FLASH Flex™ Aorto-Ostial Angioplasty Systemscore 12.3 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K180921Sapphire II PRO Balloon Dilatation Catheter
Summary page 6
…lassification: C. PREDICATE DEVICE (807.92(a)(3)) The legally marketed device(s) to which substantial equivalence is/are claimed is: Predicate Device: K180921 Sapphire II PRO Balloon Dilatation Catheter, manufactured by OrbusNeich Medical Trading Inc. Reference Devices:…
Orbusneich Medical Trading, Inc.2018—
†K220629Emerge Monorail PTCA Dilatation CatheterBoston Scientific2022—
†K141025Artimes Balloon Dilatation CatheterBrosmed Medical2014—
†K141236NC Emerge Ptca Dilatation Catheter (Monorail), NC Emerge Ptca Dilatation Catheter…Boston Scientific Corporation20141
†K163372RX Takeru Balloon Dilatation CatheterKANEKA Corporation2017—

Also cleared against K180921: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 5 companies; a new generation was cleared every 3.2 years on median.
  • None of the 8 ancestors has a recall.
  • 2 other devices also cite its predicate K180921.

How does its category compare?

All LOX devices

LOX Catheters, Transluminal Coronary Angioplasty, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · LOX

4in 2024

2007: 192008: 222009: 282010: 322011: 92012: 102013: 62014: 62015: 42016: 92017: 62018: 72019: 12020: 12021: 62022: 52023: 42024: 42026 (partial year): 6
2007high 32 (2010) · low 0 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LOX

241in 2024

2011: 103 days median2012: 120 days median2013: 123 days median2014: 166 days median2015: 119 days median2016: 116 days median2017: 113 days median2018: 80 days median2021: 167 days median2022: 121 days median2023: 138 days median2024: 241 days median2026 (partial year): 156 days median
2007high 241 (2024) · low 80 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LOX

4in 2019

2007: 12008: 802019: 4
2007high 80 (2008) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LOX

1,890in 2025

2007: 1,0532008: 1,0632009: 1,3532010: 1,3922011: 2,0902012: 2,0922013: 2,4362014: 2,3162015: 2,0602016: 2,5782017: 2,7532018: 2,2252019: 2,1022020: 1,9742021: 1,7382022: 1,8162023: 1,7202024: 1,8042025: 1,890
2007high 2,753 (2017) · low 1,053 (2007)2025

MAUDE reports naming product code LOX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200719—11,053
200822—801,063
200928—01,353
201032—01,392
2011910302,090
20121012002,092
2013612302,436
2014616602,316
2015411902,060
2016911602,578
2017611302,753
201878002,225
20191—42,102
20201—01,974
2021616701,738
2022512101,816
2023413801,720
2024424101,804
20250—01,890
202661560—

What is it indicated for?

Ryurei (1.5 mm) is indicated for: • Balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis in patients evidencing coronary ischemia for the purpose of improving myocardial perfusion. • Balloon dilatation of a coronary artery occlusion for the treatment of acute myocardial infarction. Ryurei (2.0–4.0 mm) is indicated for: • Balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis in…

Read the full statement (108 words)

Ryurei (1.5 mm) is indicated for:

• Balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis in patients evidencing coronary ischemia for the purpose of improving myocardial perfusion.

• Balloon dilatation of a coronary artery occlusion for the treatment of acute myocardial infarction.

Ryurei (2.0–4.0 mm) is indicated for:

• Balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis in patients evidencing coronary ischemia for the purpose of improving myocardial perfusion.

• Balloon dilatation of a coronary artery occlusion for the treatment of acute myocardial infarction.

• Balloon post-deployment expansion of balloon expandable stents (bare metal and drug-eluting).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K252295: Ryurei.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K252295

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026