510(k) Report

510(k) · Cleared

Cleared

CAD - Lower GI (EC07-01)

K252853510(k) TraditionalCleared Aug 5, 2026331-day reviewClass II21 CFR 876.1520

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Xiamen Inno Medical Technology Co., Ltd. · QNP Gastrointesinal Lesion Software Detection System

Cleared on Aug 5, 2026 as substantially equivalent to K233964 (Cosmo Artificial Intelligence - Ai, Ltd., 2024) and 1 other predicate after a 331-day review. Its family tree reaches back 4 generations to 2021.

Decided
Aug 5, 2026
Review
331 days
Class
Class II
Product code
QNP
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to DEN200055 (2021). No later device cites it as a predicate yet.

  1. Root · 4 generations backDEN200055 GI GeniusCosmo Artificial Intelligence - Ai, Ltd. · 2021
  2. 3 generations backK211951 GI GeniusCosmo Artificial Intelligence - Ai, Ltd. · 2021
  3. 2 generations backK231143 GI Genius System 100 and GI Genius System 200Cosmo Artificial Intelligence - Ai, Ltd. · 2023
  4. 1 generation backK233964 GI Genius™ Module 100 (GGM100.US); GI Genius™ Module 200…Cosmo Artificial Intelligence - Ai, Ltd. · 2024
  5. This deviceK252853 CAD - Lower GI (EC07-01)Xiamen Inno Medical Technology Co., Ltd. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4DEN200055GI GeniusCosmo Artificial Intelligence - Ai, Ltd.2021—
−3K211951GI GeniusCosmo Artificial Intelligence - Ai, Ltd.2021—
−2K231143GI Genius System 100 and GI Genius System 200Cosmo Artificial Intelligence - Ai, Ltd.2023—
−1K233964GI Genius™ Module 100 (GGM100.US); GI Genius™ Module 200 (GGM200.US)…Cosmo Artificial Intelligence - Ai, Ltd.2024—
0 (this device)K252853CAD - Lower GI (EC07-01)Xiamen Inno Medical Technology Co., Ltd.2026—
FIG. 1 — Lineage of K252853, 2021–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QNP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QNP device

  1. #1 K252178 Magentiq-Colo (ME-Apds)score 14.0 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K233964GI Genius™ Module 100 (GGM100.US); GI Genius™ Module 200 (GGM200.US); ColonPRO™ 4.0…
Summary page 5
…n Name: Gastrointestinal Lesion Software Detection System Regulatory Class: Class II Product Code: QNP Premarket Notification: K233964 Manufacturer: Cosmo Artificial Intelligence - AI Ltd IV Predicate Device 2 Trade/Device Name:…
Cosmo Artificial Intelligence - Ai, Ltd.2024—
*DEN200055GI Genius
Summary page 5
…Regulation Name: Gastrointestinal Lesion Software Detection System Regulatory Class: Class II Product Code: QNP Submission Number: DEN200055 Manufacturer: Cosmo Artificial Intelligence - AI, LTD…
Cosmo Artificial Intelligence - Ai, Ltd.2021—

Also cleared against K233964: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 1.8 years on median.
  • None of the 4 ancestors has a recall.
  • 1 other device also cites its predicate K233964.

How does its category compare?

All QNP devices

QNP Gastrointesinal Lesion Software Detection System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · QNP

5in 2025

2021: 32022: 12023: 42024: 52025: 52026 (partial year): 5
2007high 5 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QNP

28in 2025

2023: 140 days median2024: 29 days median2025: 28 days median2026 (partial year): 169 days median
2007high 169 (2026) · low 28 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QNP

No recall names QNP since 2007.

Adverse event reports per year · QNP

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2025

MAUDE reports naming product code QNP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20213—00
20221—00
2023414000
202452901
202552800
202651690—

What is it indicated for?

CAD - Lower GI is a computer-assisted reading tool intended to aid qualified endoscopists in detecting suspected colonic mucosal lesions, such as polyps and adenomas, in real-time endoscopic images obtained during colorectal endoscopy. The device is intended for use in adult patients undergoing colorectal cancer screening or surveillance colonoscopy in medical institutions. The device detects and displays areas of suspected lesions to assist endoscopists…

Read the full statement (128 words)

CAD - Lower GI is a computer-assisted reading tool intended to aid qualified endoscopists in detecting suspected colonic mucosal lesions, such as polyps and adenomas, in real-time endoscopic images obtained during colorectal endoscopy.

The device is intended for use in adult patients undergoing colorectal cancer screening or surveillance colonoscopy in medical institutions.

The device detects and displays areas of suspected lesions to assist endoscopists during colorectal endoscopy. The device is not intended to characterize lesions or replace clinical judgment. Physicians shall evaluate the device output together with the endoscopic images and other clinical information and shall not make clinical decisions solely based on the device output.

The product is intended to be used only with specified compatible image processors and video endoscopes under white light and NBI modes.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K252853: CAD - Lower GI (EC07-01).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K252853

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026