510(k) Report

510(k) · Cleared

Cleared

Caddie

K260133510(k) SpecialCleared Sep 12, 2026239-day reviewClass II21 CFR 876.1520

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Odin Medical Limited · QNP Gastrointesinal Lesion Software Detection System

Cleared on Sep 12, 2026 as substantially equivalent to K252586 (Odin Medical Limited, 2025) after a 239-day review. Its family tree reaches back 3 generations to 2021.

Decided
Sep 12, 2026
Review
239 days
Class
Class II
Product code
QNP
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to DEN200055 (2021). No later device cites it as a predicate yet.

  1. Root · 3 generations backDEN200055 GI GeniusCosmo Artificial Intelligence - Ai, Ltd. · 2021
  2. 2 generations backK240044 CaddieOdin Medical Limited · 2024
  3. 1 generation backK252586 CaddieOdin Medical Limited · 2025
  4. This deviceK260133 CaddieOdin Medical Limited · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3DEN200055GI GeniusCosmo Artificial Intelligence - Ai, Ltd.2021—
−2K240044CaddieOdin Medical Limited2024—
−1K252586CaddieOdin Medical Limited2025—
0 (this device)K260133CaddieOdin Medical Limited2026—
FIG. 1 — Lineage of K260133, 2021–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QNP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QNP device

  1. #1 K252178 Magentiq-Colo (ME-Apds)score 14.0 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K252586Caddie
Summary page 5
…QNP, SBX Classification Name: Gastrointestinal Lesion Software Detection System Class: Class II Predicate Device: K252586 CADDIE – Odin Medical LTD Page 1 of 14 === Page…
Odin Medical Limited2025—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 1.1 years on median.
  • None of the 3 ancestors has a recall.

How does its category compare?

All QNP devices

QNP Gastrointesinal Lesion Software Detection System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · QNP

5in 2025

2021: 32022: 12023: 42024: 52025: 52026 (partial year): 5
2007high 5 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QNP

28in 2025

2023: 140 days median2024: 29 days median2025: 28 days median2026 (partial year): 169 days median
2007high 169 (2026) · low 28 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QNP

No recall names QNP since 2007.

Adverse event reports per year · QNP

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2025

MAUDE reports naming product code QNP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20213—00
20221—00
2023414000
202452901
202552800
202651690—

What is it indicated for?

The CADDIE computer-assisted detection device is intended to assist the gastroenterologist in detecting suspected colorectal polyps only. The gastroenterologist is responsible for reviewing CADDIE suspected polyp areas and confirming the presence or absence of a polyp based on their own medical judgment.

CADDIE is not intended to replace a full patient evaluation, nor is it intended to be relied upon to make a primary interpretation of endoscopic procedures, medical diagnosis, or recommendations of treatment/course of action for patients.

The CADDIE computer-assisted detection device is limited for use with standard white-light endoscopy imaging only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K260133: Caddie.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K260133

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026