510(k) Report

510(k) · Cleared

Cleared

Ascent3T Neonatal Magnetic Resonance Imaging System

K253499510(k) TraditionalCleared Jan 26, 202689-day reviewClass II21 CFR 892.1000

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Eyas Medical Imaging, Inc. · LNH System, Nuclear Magnetic Resonance Imaging

Cleared on Jan 26, 2026 as substantially equivalent to K170978 (Aspect Imaging, Ltd., 2017) after an 89-day review. Its family tree reaches back 5 generations to 2000.

Decided
Jan 26, 2026
Review
89 days
Class
Class II
Product code
LNH
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K001773 (2000). No later device cites it as a predicate yet.

  1. Root · 5 generations backK001773 OrthoneOni, Inc. · 2000 · Recalled
  2. 4 generations backK120701 M2 Wrist Mri SystemAspect Imaging, Ltd. · 2013
  3. 3 generations backK130692 M2 Wrist 2 Mri SystemAspect Imaging, Ltd. · 2014
  4. 2 generations backK160185 Wrist 3Aspect Imaging, Ltd. · 2016
  5. 1 generation backK170978 Embrace Neonatal MRI SystemAspect Imaging, Ltd. · 2017
  6. This deviceK253499 Ascent3T Neonatal Magnetic Resonance Imaging SystemEyas Medical Imaging, Inc. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K001773OrthoneOni, Inc.20001
−4K120701M2 Wrist Mri SystemAspect Imaging, Ltd.2013—
−3K130692M2 Wrist 2 Mri SystemAspect Imaging, Ltd.2014—
−2K160185Wrist 3Aspect Imaging, Ltd.2016—
−1K170978Embrace Neonatal MRI SystemAspect Imaging, Ltd.2017—
0 (this device)K253499Ascent3T Neonatal Magnetic Resonance Imaging SystemEyas Medical Imaging, Inc.2026—
FIG. 1 — Lineage of K253499, 2000–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LNH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LNH device

  1. #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170978Embrace Neonatal MRI System
Summary page 6
…Neonatal MRI System Device: Manufacturer: Aspect Imaging Ltd. 510(k) Number: K170978 Product Code: LNH Subsequent Product Code: MOS…
Aspect Imaging, Ltd.2017—
†K193215Achieva, Intera, Ingenia, Ingneia CX, Ingenia Elition, and Ingenia Ambition MR SystemsPhilips Medical Systems Nederland B.V.2020152

Also cleared against K170978: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 3 companies; a new generation was cleared every 2.1 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • 3 other devices also cite its predicate K170978.

How does its category compare?

All LNH devices

LNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · LNH

26in 2025

2007: 122008: 192009: 172010: 122011: 162012: 222013: 192014: 172015: 192016: 202017: 182018: 292019: 262020: 322021: 272022: 302023: 302024: 262025: 262026 (partial year): 24
2007high 32 (2020) · low 12 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LNH

122in 2025

2007: 35 days median2008: 53 days median2009: 70 days median2010: 94 days median2011: 81 days median2012: 89 days median2013: 108 days median2014: 108 days median2015: 140 days median2016: 108 days median2017: 98 days median2018: 128 days median2019: 62 days median2020: 121 days median2021: 87 days median2022: 74 days median2023: 124 days median2024: 104 days median2025: 122 days median2026 (partial year): 126 days median
2007high 140 (2015) · low 35 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LNH

8in 2025

2007: 252008: 122009: 72010: 172011: 112012: 52013: 22014: 132015: 12, 2 Class I2016: 12018: 712019: 52020: 42021: 412022: 132023: 10, 1 Class I2024: 42025: 8, 5 Class I2026 (partial year): 43
2007high 71 (2018) · low 0 (2017)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · LNH

1,263in 2025

2007: 1142008: 1672009: 1942010: 1652011: 1822012: 1702013: 1072014: 1192015: 1132016: 1352017: 1212018: 1582019: 1582020: 982021: 842022: 1382023: 1592024: 2812025: 1,263
2007high 1,263 (2025) · low 84 (2021)2025

MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123525114
2008195312167
200917707194
2010129417165
2011168111182
201222895170
2013191082107
20141710813119
20151914012 (2)113
2016201081135
201718980121
20182912871158
201926625158
202032121498
202127874184
2022307413138
20233012410 (1)159
2024261044281
2025261228 (5)1,263
20262412643—

What is it indicated for?

The Ascent3T Neonatal Magnetic Resonance Imaging System (Ascent3T) is a whole-body magnetic resonance scanner designed for neonates and infants. The system can produce cross-sectional images of the internal structure of the head, body or extremities in any orientation.

Images produced by the Ascent3T show the spatial distribution of protons exhibiting magnetic resonance. Images produced by the Ascent3T, when interpreted by a trained physician, may provide information useful in diagnosis.

The Ascent3T Neonatal Magnetic Resonance Imaging System is suitable for neonates and infants weighing up to 9kg (19.8 lbs).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253499: Ascent3T Neonatal Magnetic Resonance Imaging System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K253499

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026