Zimmer Biomet OSS™ Orthopedic Salvage System OsseoTi® Sleeves and Augments

K253515510(k) TraditionalCleared Aug 24, 2026290-day reviewClass II21 CFR 888.3350

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomet Orthopedics, Inc. · JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented

Cleared on Aug 24, 2026 as substantially equivalent to K141331 (Biomet, Inc., 2014) and 1 other predicate after a 290-day review. Its family tree reaches back 12 generations to 1981.

Decided
Aug 24, 2026
Review
290 days
Class
Class II
Product code
JDI
Recalls
None
Predicates
2

Its longest line of descent runs back 12 generations to K810258 (1981). 129 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2014: 1 other ancestor2013: 1 other ancestor2011: 3 other ancestors2008: 1 other ancestor2005: 8 other ancestors2003: 8 other ancestors2002: 7 other ancestors2000: 9 other ancestors1999: 9 other ancestors2012: 1 other ancestor2010: 5 other ancestors2007: 6 other ancestors2006: 1 other ancestor1997: 5 other ancestors1992: 3 other ancestors2009: 2 other ancestors2004: 3 other ancestors1998: 2 other ancestors1996: 8 other ancestors1991: 2 other ancestors2001: 5 other ancestors1995: 6 other ancestors1994: 14 other ancestors1983: 1 other ancestor1993: 3 other ancestors1986: 2 other ancestors1985: 1 other ancestorK810258 · Proximal Fermoral Hip Replacement · Biomet, Inc. · 1981K974558 · Salvage/Onocology Hip and Total Femur System · Biomet, Inc. · 1998K032396 · Ringloc 36MM Line and Modular Femoral Heads · Biomet, Inc. · 2003 · recalled×2: 2 generations cleared close together, K042051 (2005), K051411 (2005) K061312 · 36MM Biolox Delta Ceramic Heads · Biomet, Inc. · 2006K073102 · Biolox Delta Ceramic Heads with 100KGY E-Poly Acetabular Liners · Biomet Manufacturing Corp · 2007K082996 · Biolox Delta Option Ceramic Heads · Biomet, Inc. · 2009 · recalledK093549 · 44MM E1 Acetabular Liner with 44MM Biolox Delta Option Ceramic Head or 44MM M a Magnum · Biomet Manufacturing Corp · 2009K121874 · G7 Acetabular System · Biomet Manufacturing Corp · 2012 · recalledK140669 · G7 Osseoti Acetublar Shells · Biomet, Inc. · 2014K142814 · Biomet Orthopaedic Salvage System (OSSTM) - Proximal Femoral & Hybrid Tibial · Biomet Manufacturing, LLC · 2015 · recalled19801990200020102020
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 11 other ancestors3 generations back: 10 other ancestors4 generations back: 17 other ancestors5 generations back: 21 other ancestors6 generations back: 19 other ancestors7 generations back: 22 other ancestors8 generations back: 12 other ancestors9 generations back: 4 other ancestors K142814 · Biomet Orthopaedic Salvage System (OSSTM) - Proximal Femoral & Hybrid Tibial · Biomet Manufacturing, LLC · 2015 · recalledK140669 · G7 Osseoti Acetublar Shells · Biomet, Inc. · 2014K121874 · G7 Acetabular System · Biomet Manufacturing Corp · 2012 · recalledK093549 · 44MM E1 Acetabular Liner with 44MM Biolox Delta Option Ceramic Head or 44MM M a Magnum · Biomet Manufacturing Corp · 2009K082996 · Biolox Delta Option Ceramic Heads · Biomet, Inc. · 2009 · recalledK073102 · Biolox Delta Ceramic Heads with 100KGY E-Poly Acetabular Liners · Biomet Manufacturing Corp · 2007K061312 · 36MM Biolox Delta Ceramic Heads · Biomet, Inc. · 2006K051411 · Arcomxl Polyethylene Liners and Biolox Delta Heads · Biomet, Inc. · 2005 · recalledK042051 · Arcomxl Polyethylene Liners · Biomet, Inc. · 2005 · recalledK032396 · Ringloc 36MM Line and Modular Femoral Heads · Biomet, Inc. · 2003 · recalledK974558 · Salvage/Onocology Hip and Total Femur System · Biomet, Inc. · 1998K810258 · Proximal Fermoral Hip Replacement · Biomet, Inc. · 1981−10−50
  1. Root · 12 generations backK810258 Proximal Fermoral Hip ReplacementBiomet, Inc. · 1981
  2. 8 generations between
  3. 3 generations backK121874 G7 Acetabular SystemBiomet Manufacturing Corp · 2012 · Recalled
  4. 2 generations backK140669 G7 Osseoti Acetublar ShellsBiomet, Inc. · 2014
  5. 1 generation backK142814 Biomet Orthopaedic Salvage System (OSSTM) - Proximal Femoral &…Biomet Manufacturing, LLC · 2015 · Recalled
  6. This deviceK253515 Zimmer Biomet OSS™ Orthopedic Salvage System OsseoTi® Sleeves and…Biomet Orthopedics, Inc. · 2026
Show all 12 generations
  1. Root · 12 generations backK810258 Proximal Fermoral Hip ReplacementBiomet, Inc. · 1981
  2. 11 generations backK974558 Salvage/Onocology Hip and Total Femur SystemBiomet, Inc. · 1998
  3. 10 generations backK032396 Ringloc 36MM Line and Modular Femoral HeadsBiomet, Inc. · 2003 · Recalled
  4. 9 generations backK042051 Arcomxl Polyethylene LinersBiomet, Inc. · 2005 · Recalled
  5. 8 generations backK051411 Arcomxl Polyethylene Liners and Biolox Delta HeadsBiomet, Inc. · 2005 · Recalled
  6. 7 generations backK061312 36MM Biolox Delta Ceramic HeadsBiomet, Inc. · 2006
  7. 6 generations backK073102 Biolox Delta Ceramic Heads with 100KGY E-Poly Acetabular LinersBiomet Manufacturing Corp · 2007
  8. 5 generations backK082996 Biolox Delta Option Ceramic HeadsBiomet, Inc. · 2009 · Recalled
  9. 4 generations backK093549 44MM E1 Acetabular Liner with 44MM Biolox Delta Option Ceramic Head…Biomet Manufacturing Corp · 2009
  10. 3 generations backK121874 G7 Acetabular SystemBiomet Manufacturing Corp · 2012 · Recalled
  11. 2 generations backK140669 G7 Osseoti Acetublar ShellsBiomet, Inc. · 2014
  12. 1 generation backK142814 Biomet Orthopaedic Salvage System (OSSTM) - Proximal Femoral &…Biomet Manufacturing, LLC · 2015 · Recalled
  13. This deviceK253515 Zimmer Biomet OSS™ Orthopedic Salvage System OsseoTi® Sleeves and…Biomet Orthopedics, Inc. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K810258Proximal Fermoral Hip ReplacementBiomet, Inc.1981—
−11K974558Salvage/Onocology Hip and Total Femur SystemBiomet, Inc.1998—
−10K032396Ringloc 36MM Line and Modular Femoral HeadsBiomet, Inc.20033
−9K042051Arcomxl Polyethylene LinersBiomet, Inc.20051
−8K051411Arcomxl Polyethylene Liners and Biolox Delta HeadsBiomet, Inc.20051
−7K06131236MM Biolox Delta Ceramic HeadsBiomet, Inc.2006—
−6K073102Biolox Delta Ceramic Heads with 100KGY E-Poly Acetabular LinersBiomet Manufacturing Corp2007—
−5K082996Biolox Delta Option Ceramic HeadsBiomet, Inc.20094
−4K09354944MM E1 Acetabular Liner with 44MM Biolox Delta Option Ceramic Head or 44MM M…Biomet Manufacturing Corp2009—
−3K121874G7 Acetabular SystemBiomet Manufacturing Corp20123
−2K140669G7 Osseoti Acetublar ShellsBiomet, Inc.2014—
−1K142814Biomet Orthopaedic Salvage System (OSSTM) - Proximal Femoral & Hybrid TibialBiomet Manufacturing, LLC20156
0 (this device)K253515Zimmer Biomet OSS™ Orthopedic Salvage System OsseoTi® Sleeves and AugmentsBiomet Orthopedics, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198310
198510
198620
199120
199230
199330
1994140
199560
199680
199750
199820
199990
200090
200150
200270
200380
200430
200580
200610
200760
200810
200920
201050
201130
201210
201310
201410
FIG. 1 — Lineage of K253515, 1981–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JDI device

  1. #1 K220216 C-Stem AMT LE Prosthesisscore 14.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K141331Biomet Orthopaedic Salvage System (Oss)
Summary page 5
…21 CFR 807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K141331 Biomet Orthopedic Salvage System (OSS ) Product Line JDI…
Biomet, Inc.2014—
*K142814Biomet Orthopaedic Salvage System (OSSTM) - Proximal Femoral & Hybrid Tibial
Summary page 5
…K141331 Biomet Orthopedic Salvage System (OSS ) Product Line JDI Extension K142814 Biomet Orthopedic Salvage System, Proximal Femoral and JDI…
Biomet Manufacturing, LLC20156

Also cleared against K141331: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 45 years and passes through 4 companies; a new generation was cleared every 1.5 years on median.
  • 37 of the 129 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K141331.

How does its category compare?

All JDI devices

JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · JDI

1in 2025

2007: 32008: 52009: 32011: 22012: 42013: 32014: 32015: 32016: 42017: 12018: 12019: 22020: 72021: 32022: 32023: 22024: 32025: 12026 (partial year): 2
2007high 7 (2020) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JDI

59in 2024

2007: 81 days median2008: 96 days median2009: 65 days median2012: 167 days median2013: 176 days median2014: 98 days median2015: 190 days median2016: 166 days median2020: 247 days median2021: 162 days median2022: 69 days median2024: 59 days median
2007high 247 (2020) · low 59 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JDI

1in 2025

2007: 262008: 62009: 32010: 32011: 52012: 42013: 112014: 32015: 12016: 52017: 52018: 12019: 12020: 772025: 1
2007high 77 (2020) · low 0 (2021)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JDI

1,644in 2025

2007: 6962008: 8102009: 9642010: 2,0402011: 3,1602012: 5,1222013: 5,2062014: 4,9682015: 4,9062016: 3,9952017: 6,1352018: 6,7282019: 7,4072020: 4,0152021: 3,1702022: 1,9782023: 1,6352024: 1,8212025: 1,644
2007high 7,407 (2019) · low 696 (2007)2025

MAUDE reports naming product code JDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200738126696
20085966810
20093653964
20100—32,040
20112—53,160
2012416745,122
20133176115,206
201439834,968
2015319014,906
2016416653,995
20171—56,135
20181—16,728
20192—17,407
20207247774,015
2021316203,170
202236901,978
20232—01,635
202435901,821
20251—11,644
20262—0—

What is it indicated for?

OSS System Indications: • Painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis, or traumatic arthritis. • Correction of varus, valgus, or posttraumatic deformity. • Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. • Ligament deficiencies. • Tumor resections. • Treatment of non-unions, femoral neck fracture, and trochanteric fractures of the proximal femur with head…

Read the full statement (99 words)

OSS System Indications:

• Painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis, or traumatic arthritis.

• Correction of varus, valgus, or posttraumatic deformity.

• Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement.

• Ligament deficiencies.

• Tumor resections.

• Treatment of non-unions, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques.

• Revision of previously failed total joint arthroplasty.

• Trauma.

These devices are to be used with bone cement unless composed of OsseoTi® titanium alloy or a proximal femur is indicated for use (USA).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253515: Zimmer Biomet OSS™ Orthopedic Salvage System OsseoTi® Sleeves and Augments.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K253515

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026