510(k) Report

510(k) · Cleared

Cleared

AiORTA - Plan v2.0

K254207510(k) TraditionalCleared Mar 30, 202691-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

ViTAA Medical Solutions, Inc. · QIH Automated Radiological Image Processing Software

Cleared on Mar 30, 2026 as substantially equivalent to K250337 (ViTAA Medical Solutions, Inc., 2025) after a 91-day review. Its family tree reaches back 10 generations to 1991.

Decided
Mar 30, 2026
Review
91 days
Class
Class II
Product code
QIH
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K913770 (1991). 68 ancestors in all, the oldest K871859 (1987). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2016: 1 other ancestor2015: 1 other ancestor2012: 2 other ancestors2006: 3 other ancestors2001: 7 other ancestors2011: 1 other ancestor2008: 1 other ancestor2005: 2 other ancestors2004: 6 other ancestors2002: 4 other ancestors2000: 3 other ancestors1997: 5 other ancestors2010: 1 other ancestor2003: 3 other ancestors1999: 1 other ancestor1998: 3 other ancestors1996: 5 other ancestors1995: 3 other ancestors1994: 3 other ancestors1993: 1 other ancestor1987: 1 other ancestor1991: 1 other ancestorK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K963345 · Advantage Windows Tissue Volume Option · GE Medical Systems · 1996K013381 · Advanced Lung Analysis-1 · General Electric Co. · 2001K022013 · Lungcare CT Software Package · Siemens Medical Solutions USA, Inc. · 2002K033374 · Lungcare CT Software Package with Extended Functionality · Siemens AG Medical Solutions · 2003K041807 · Lung Car 1.1 · Medicsight · 2004K061214 · Aquariusaps Server · Terarecon,Inc. · 2006K121916 · Intuition · Terarecon,Inc. · 2013 · recalledK191585 · iNtuition-Structural Heart Module · Terarecon,Inc. · 2019K250337 · AiORTA - Plan · ViTAA Medical Solutions, Inc. · 20251990200020102020
  1. Root · 10 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 6 generations between
  3. 3 generations backK121916 IntuitionTerarecon,Inc. · 2013 · Recalled
  4. 2 generations backK191585 iNtuition-Structural Heart ModuleTerarecon,Inc. · 2019
  5. 1 generation backK250337 AiORTA - PlanViTAA Medical Solutions, Inc. · 2025
  6. This deviceK254207 AiORTA - Plan v2.0ViTAA Medical Solutions, Inc. · 2026
Show all 10 generations
  1. Root · 10 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 9 generations backK963345 Advantage Windows Tissue Volume OptionGE Medical Systems · 1996
  3. 8 generations backK013381 Advanced Lung Analysis-1General Electric Co. · 2001
  4. 7 generations backK022013 Lungcare CT Software PackageSiemens Medical Solutions USA, Inc. · 2002
  5. 6 generations backK033374 Lungcare CT Software Package with Extended FunctionalitySiemens AG Medical Solutions · 2003
  6. 5 generations backK041807 Lung Car 1.1Medicsight · 2004
  7. 4 generations backK061214 Aquariusaps ServerTerarecon,Inc. · 2006
  8. 3 generations backK121916 IntuitionTerarecon,Inc. · 2013 · Recalled
  9. 2 generations backK191585 iNtuition-Structural Heart ModuleTerarecon,Inc. · 2019
  10. 1 generation backK250337 AiORTA - PlanViTAA Medical Solutions, Inc. · 2025
  11. This deviceK254207 AiORTA - Plan v2.0ViTAA Medical Solutions, Inc. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−9K963345Advantage Windows Tissue Volume OptionGE Medical Systems1996—
−8K013381Advanced Lung Analysis-1General Electric Co.2001—
−7K022013Lungcare CT Software PackageSiemens Medical Solutions USA, Inc.2002—
−6K033374Lungcare CT Software Package with Extended FunctionalitySiemens AG Medical Solutions2003—
−5K041807Lung Car 1.1Medicsight2004—
−4K061214Aquariusaps ServerTerarecon,Inc.2006—
−3K121916IntuitionTerarecon,Inc.20131
−2K191585iNtuition-Structural Heart ModuleTerarecon,Inc.2019—
−1K250337AiORTA - PlanViTAA Medical Solutions, Inc.2025—
0 (this device)K254207AiORTA - Plan v2.0ViTAA Medical Solutions, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199110
199310
199430
199530
199650
199750
199830
199910
200030
200170
200240
200330
200460
200520
200630
200810
201010
201110
201220
201510
201610
FIG. 1 — Lineage of K254207, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QIH device

  1. #1 K213998 cvi42 Auto Imaging Software Applicationscore 23.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K250337AiORTA - Plan
Summary page 5
…stem Common Name: Automated Radiological Image Processing Software Class: II Product Code: QIH Predicate Device Trade Name: AiORTA – Plan v1.1 (K250337) Medical Specialty: Radiology Classification: 21 CFR 892.2050 Regulation Name: Medical Image Management and Processing Sy…
ViTAA Medical Solutions, Inc.2025—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 35 years and passes through 7 companies; a new generation was cleared every 4.8 years on median.
  • 13 of the 68 ancestors have a recall of any class.

How does its category compare?

All QIH devices

QIH Automated Radiological Image Processing Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · QIH

94in 2025

2019: 22020: 112021: 192022: 252023: 452024: 642025: 942026 (partial year): 78
2007high 94 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QIH

150in 2025

2020: 145 days median2021: 125 days median2022: 134 days median2023: 151 days median2024: 141 days median2025: 150 days median2026 (partial year): 130 days median
2007high 151 (2023) · low 125 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QIH

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QIH

4in 2025

2024: 22025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code QIH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20192—00
20201114500
20211912500
20222513400
20234515100
20246414102
20259415004
2026781301—

What is it indicated for?

The AiORTA - Plan tool is an image analysis software tool for volumetric assessment, image analysis, geometric analysis, and pre-operative sizing and planning. It provides volumetric visualization and measurements based on 3D reconstruction computed from cardiovascular CTA scans. The software device is intended to provide adjunct information to a licensed healthcare practitioner (HCP) in addition to clinical data and other inputs, as a measurement tool…

Read the full statement (113 words)

The AiORTA - Plan tool is an image analysis software tool for volumetric assessment, image analysis, geometric analysis, and pre-operative sizing and planning. It provides volumetric visualization and measurements based on 3D reconstruction computed from cardiovascular CTA scans. The software device is intended to provide adjunct information to a licensed healthcare practitioner (HCP) in addition to clinical data and other inputs, as a measurement tool used in assessment of aortic aneurysm, pre-operative evaluation, planning and sizing for cardiovascular intervention and surgery, and for post-operative evaluation in patients 22 years old and older.

The device is not intended to provide stand-alone diagnosis or suggest an immediate course of action in treatment or patient management

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K254207: AiORTA - Plan v2.0.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K254207

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026