510(k) · Cleared
ClearedBiomonitor IV (471155)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biotronik, Inc. · MXD Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection)
Cleared on May 1, 2026 as substantially equivalent to K230375 (Biotronik, Inc., 2023) after a 30-day review. Its family tree reaches back 15 generations to 1987.
- Decided
- May 1, 2026
- Review
- 30 days
- Class
- Class II
- Product code
- MXD
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 15 generations to K864889 (1987). 63 ancestors in all, the oldest K832113 (1983). No later device cites it as a predicate yet.
- Root · 15 generations backK864889 Omni-TrakInvivo Research Labs, Inc. · 1987
- 11 generations between
- 3 generations backK201865 Biomonitor III, Biomonitor IIImBiotronik, Inc. · 2020
- 2 generations backK221856 BIOMONITOR IIIm, BIOMONITOR IIIBiotronik, Inc. · 2022
- 1 generation backK230375 Biomonitor IVBiotronik, Inc. · 2023
- This deviceK261074 Biomonitor IV (471155)Biotronik, Inc. · 2026
Show all 15 generations
- Root · 15 generations backK864889 Omni-TrakInvivo Research Labs, Inc. · 1987
- 14 generations backK950264 MaglifeOdam · 1996
- 13 generations backK023195 Maglife C/Maglife C PlusSchiller Medical S.A. · 2003
- 12 generations backK040915 Magnitude 3150M Mri Patient Monitor, Model 3150MInvivo Research, Inc. · 2004
- 11 generations backK050399 Mri Compatible Patient Monitoring System, Model 3160Invivo Research, Inc. · 2005
- 10 generations backK053462 3160 Mri Patient Monitoring SystemInvivo Corporation · 2006 · Recalled
- 9 generations backK071641 Reveal XT; Insertable Cardiac Monitor (Model 9529), Patient…Medtronic, Inc. · 2007
- 8 generations backK132960 BiomonitorBiotronik, Inc. · 2014
- 7 generations backK143503 BioMonitorBiotronik, Inc. · 2015
- 6 generations backK152995 BioMonitor 2-AF, BioMonitor 2-SBiotronik, Inc. · 2016
- 5 generations backK190548 BIOMONITOR III, Remote Assistant IIIBiotronik, Inc. · 2019
- 4 generations backK200444 Biomonitor III, Biomonitor IIImBiotronik, Inc. · 2020
- 3 generations backK201865 Biomonitor III, Biomonitor IIImBiotronik, Inc. · 2020
- 2 generations backK221856 BIOMONITOR IIIm, BIOMONITOR IIIBiotronik, Inc. · 2022
- 1 generation backK230375 Biomonitor IVBiotronik, Inc. · 2023
- This deviceK261074 Biomonitor IV (471155)Biotronik, Inc. · 2026
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −15 | K864889 | Omni-Trak | Invivo Research Labs, Inc. | 1987 | — |
| −14 | K950264 | Maglife | Odam | 1996 | — |
| −13 | K023195 | Maglife C/Maglife C Plus | Schiller Medical S.A. | 2003 | — |
| −12 | K040915 | Magnitude 3150M Mri Patient Monitor, Model 3150M | Invivo Research, Inc. | 2004 | — |
| −11 | K050399 | Mri Compatible Patient Monitoring System, Model 3160 | Invivo Research, Inc. | 2005 | — |
| −10 | K053462 | 3160 Mri Patient Monitoring System | Invivo Corporation | 2006 | 2 |
| −9 | K071641 | Reveal XT; Insertable Cardiac Monitor (Model 9529), Patient Assistant (Model… | Medtronic, Inc. | 2007 | — |
| −8 | K132960 | Biomonitor | Biotronik, Inc. | 2014 | — |
| −7 | K143503 | BioMonitor | Biotronik, Inc. | 2015 | — |
| −6 | K152995 | BioMonitor 2-AF, BioMonitor 2-S | Biotronik, Inc. | 2016 | — |
| −5 | K190548 | BIOMONITOR III, Remote Assistant III | Biotronik, Inc. | 2019 | — |
| −4 | K200444 | Biomonitor III, Biomonitor IIIm | Biotronik, Inc. | 2020 | — |
| −3 | K201865 | Biomonitor III, Biomonitor IIIm | Biotronik, Inc. | 2020 | — |
| −2 | K221856 | BIOMONITOR IIIm, BIOMONITOR III | Biotronik, Inc. | 2022 | — |
| −1 | K230375 | Biomonitor IV | Biotronik, Inc. | 2023 | — |
| 0 (this device) | K261074 | Biomonitor IV (471155) | Biotronik, Inc. | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1983 | 1 | 0 |
| 1986 | 1 | 0 |
| 1987 | 1 | 0 |
| 1988 | 1 | 0 |
| 1989 | 1 | 0 |
| 1990 | 1 | 0 |
| 1991 | 1 | 0 |
| 1992 | 2 | 0 |
| 1993 | 2 | 0 |
| 1994 | 3 | 0 |
| 1995 | 7 | 0 |
| 1996 | 3 | 0 |
| 1997 | 2 | 0 |
| 1998 | 2 | 0 |
| 1999 | 7 | 0 |
| 2000 | 3 | 0 |
| 2001 | 3 | 0 |
| 2002 | 2 | 0 |
| 2003 | 1 | 0 |
| 2004 | 2 | 0 |
| 2005 | 1 | 0 |
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MXD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MXD device
- #1 K262735 LINQ II Insertable Cardiac Monitor (ICM) (LNQ22)score 16.7 · 17 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K230375 | Biomonitor IVSummary page 5…21 CFR 807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K230375 BIOMONITOR IV MXD Device Description Summary… | 2023 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 39 years and passes through 7 companies; a new generation was cleared every 1.3 years on median.
- 4 of the 63 ancestors have a recall of any class.
How does its category compare?
All MXD devicesMXD Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection): FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · MXD
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MXD
36in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MXD
5so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MXD
3,384in 2025
MAUDE reports naming product code MXD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 1 |
| 2014 | 2 | — | 0 | 0 |
| 2015 | 2 | — | 0 | 2 |
| 2016 | 3 | 63 | 0 | 21 |
| 2017 | 4 | 52 | 0 | 37 |
| 2018 | 0 | — | 0 | 32 |
| 2019 | 1 | — | 0 | 70 |
| 2020 | 4 | 127 | 0 | 228 |
| 2021 | 4 | 57 | 0 | 694 |
| 2022 | 2 | — | 1 | 1,362 |
| 2023 | 6 | 76 | 1 | 1,766 |
| 2024 | 1 | — | 1 | 3,019 |
| 2025 | 3 | 36 | 0 | 3,384 |
| 2026 | 2 | — | 5 | — |
What is it indicated for?
The BIOMONITOR IV is indicated to detect the following cardiac arrhythmias:
* Pause
* Tachycardia
* Sudden Rate Drop
* Bradycardia
* Atrial fibrillation
The BIOMONITOR IV is indicated for use in:
* Patients who experience transient symptoms that may suggest a cardiac arrhythmia
* Patients with clinical syndromes or situations at increased risk of cardiac arrhythmias
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K261074 · printed Nov 4, 2026
Cite this page
510(k) Report. “K261074: Biomonitor IV (471155).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K261074
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded Oct 30, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026