510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Tygon Tubing

K803277510(k) TraditionalCleared Jan 13, 198115-day reviewClass II21 CFR 870.4390Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Electromedics, Inc. · DWE Tubing, Pump, Cardiopulmonary Bypass

Cleared on Jan 13, 1981 after a 15-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 2 later devices descend from it. It has been recalled once.

Decided
Jan 13, 1981
Review
15 days
Class
Class II
Product code
DWE
Recalls
1
Predicates
0

2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2004: 1 descendant cleared1998: 1 descendant cleared19801990200020102020
  1. This deviceK803277 Tygon TubingElectromedics, Inc. · 1981
  2. Descendant · cites it directly · 1 of its ownK964205 Better-TubingCirculatory Technology, Inc. · 1998
  3. Descendant · cites it directly · 0 of its ownK041650 Micro PrimeInnovx Medical, Inc. · 2004

Most influential descendants

Showing 2 of 2 · See all
  • K964205Better-TubingCirculatory Technology, Inc. · 1998 · cites it directly1descendant
  • K041650Micro PrimeInnovx Medical, Inc. · 2004 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K803277Tygon TubingElectromedics, Inc.1981—
+1K964205Better-TubingCirculatory Technology, Inc.1998—
+1K041650Micro PrimeInnovx Medical, Inc.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199810
200410
FIG. 1 — Lineage of K803277, 1981–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DWE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DWE device

  1. #1 K233702 SMARxT Tubing and Connectorsscore 7.8 · 1 generation · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K964205Better-TubingCirculatory Technology, Inc.19981
K041650Micro PrimeInnovx Medical, Inc.20040

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 27, 2018Class IIZ-0785-2019Process controlMedtronic discovered that certain Y-connectors included in the suction lines have exhibited tearing and cracking. These defects could cause the Y-connectors to leak when in use, which could result in potential blood loss and a breach in…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K964205 (Circulatory Technology, Inc., 1998) has gone furthest, with 1 descendant of its own.

How does its category compare?

All DWE devices

DWE Tubing, Pump, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DWE

1in 2024

2008: 12009: 12014: 12015: 12024: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DWE

Too few DWE 510(k)s in any year since 2007 to give a median.

Recalls per year · DWE

2in 2017

2007: 22009: 12010: 22011: 22014: 12017: 2
2007high 2 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DWE

80in 2025

2007: 102008: 122009: 172010: 202011: 92012: 72013: 212014: 1292015: 1332016: 1512017: 1312018: 1342019: 822020: 452021: 412022: 1232023: 2862024: 2212025: 80
2007high 286 (2023) · low 7 (2012)2025

MAUDE reports naming product code DWE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—210
20081—012
20091—117
20100—220
20110—29
20120—07
20130—021
20141—1129
20151—0133
20160—0151
20170—2131
20180—0134
20190—082
20200—045
20210—041
20220—0123
20230—0286
20241—0221
20250—080
20260—0—
Cite this page

510(k) Report. “K803277: Tygon Tubing.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K803277

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026