510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

Prompt Inoculation System

K820299510(k) TraditionalCleared Mar 15, 198239-day reviewClass II21 CFR 866.1640Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

3M Company · LIE Reagent/Device, Inoculum Calibration

Cleared on Mar 15, 1982 after a 39-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 1 later device descends from it. It has been recalled 2 times.

Decided
Mar 15, 1982
Review
39 days
Class
Class II
Product code
LIE
Recalls
2
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2023: 1 descendant cleared19801990200020102020
  1. This deviceK820299 Prompt Inoculation System3M Company · 1982
  2. Descendant · cites it directly · 0 of its ownK221493 MicroScan Prompt Inoculation System-DBeckman Coulter, Inc. · 2023

Most influential descendants

Showing 1 of 1 · See all
  • K221493MicroScan Prompt Inoculation System-DBeckman Coulter, Inc. · 2023 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K820299Prompt Inoculation System3M Company1982—
+1K221493MicroScan Prompt Inoculation System-DBeckman Coulter, Inc.2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
FIG. 1 — Lineage of K820299, 1982–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LIE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LIE device

  1. #1 K221493 MicroScan Prompt Inoculation System-Dscore 5.1 · 1 generation · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K221493MicroScan Prompt Inoculation System-DBeckman Coulter, Inc.20230

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 13, 2019Class IIZ-1674-2020Nonconforming Material/ComponentDue to customer reports it has been determined that the inoculation system contains the incorrect prompt wands. Use of the incorrect wands could result in false -susceptible results, false-resistant results, possible misidentifications…
Sep 27, 2006Not classifiedZ-0247-2007OtherProduct does not meet performance specifications through its standardized inocula for MicroScan Dried Gram-Negative and Gram-Positive Overnight panel testing.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K221493 (Beckman Coulter, Inc., 2023) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LIE devices

LIE Reagent/Device, Inoculum Calibration: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LIE

1in 2023

2011: 22023: 1
2007high 2 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LIE

Too few LIE 510(k)s in any year since 2007 to give a median.

Recalls per year · LIE

No recall names LIE since 2007.

Adverse event reports per year · LIE

No MAUDE report names LIE since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20112—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20231—00
20240—00
20250—00
20260—0—
Cite this page

510(k) Report. “K820299: Prompt Inoculation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K820299

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026