510(k) · Cleared
ClearedCCG Cerclage System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Encore Orthopedics, Inc. · JDQ Cerclage, Fixation
Cleared on Feb 14, 1995 after a 659-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 39 later devices descend from it.
- Decided
- Feb 14, 1995
- Review
- 659 days
- Class
- Class II
- Product code
- JDQ
- Recalls
- None
- Predicates
- 0
39 later devices descend from it, 2 citing it directly.
- This deviceK932024 CCG Cerclage SystemEncore Orthopedics, Inc. · 1995
- Descendant · cites it directly · 34 of its ownK973098 Compression Cerclage Gundolf CCG-GFPlus Orthopedics · 1997
- Descendant · 2 generations on · 33 of its ownK123055 Smith & Nephew, Inc Screw and Plate System InstrumentationSmith & Nephew, Inc. · 2013
- Descendant · 3 generations on · 32 of its ownK140814 Evos Mini-Fragment Plating SystemSmith & Nephew, Inc. · 2014 · Recalled
- Descendant · 4 generations on · 14 of its ownK163361 ANTHEM™ Fracture SystemGlobus Medical, Inc. · 2017
- Descendant · 5 generations on · 11 of its ownK173166 ANTHEM Fracture SystemGlobus Medical, Inc. · 2017
Showing 5 of 39 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 39 · See all- K973098Compression Cerclage Gundolf CCG-GFPlus Orthopedics · 1997 · cites it directly34descendants
- K123055Smith & Nephew, Inc Screw and Plate System InstrumentationSmith & Nephew, Inc. · 2013 · 2 generations on33descendants
- K140814Evos Mini-Fragment Plating SystemSmith & Nephew, Inc. · 2014 · 3 generations on32descendants
- K163361ANTHEM™ Fracture SystemGlobus Medical, Inc. · 2017 · 4 generations on14descendants
- K173166ANTHEM Fracture SystemGlobus Medical, Inc. · 2017 · 5 generations on11descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K932024 | CCG Cerclage System | Encore Orthopedics, Inc. | 1995 | — |
| +1 | K973098 | Compression Cerclage Gundolf CCG-GF | Plus Orthopedics | 1997 | — |
| +2 | K123055 | Smith & Nephew, Inc Screw and Plate System Instrumentation | Smith & Nephew, Inc. | 2013 | — |
| +3 | K140814 | Evos Mini-Fragment Plating System | Smith & Nephew, Inc. | 2014 | 2 |
| +4 | K163361 | ANTHEM™ Fracture System | Globus Medical, Inc. | 2017 | — |
| +5 | K173166 | ANTHEM Fracture System | Globus Medical, Inc. | 2017 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 2 | 0 |
| 1998 | 1 | 0 |
| 2006 | 1 | 0 |
| 2009 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 1 | 0 |
| 2017 | 2 | 0 |
| 2018 | 3 | 0 |
| 2020 | 1 | 0 |
| 2021 | 2 | 0 |
| 2022 | 4 | 0 |
| 2023 | 3 | 0 |
| 2024 | 7 | 0 |
| 2025 | 7 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDQ device
- #1 K261271 Cable-Ready® Cable Grip Systemscore 14.7 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (39)
See all 392 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K973098 (Plus Orthopedics, 1997) has gone furthest, with 34 descendants of its own.
How does its category compare?
All JDQ devicesJDQ Cerclage, Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDQ
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDQ
130in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDQ
5in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDQ
84in 2025
MAUDE reports naming product code JDQ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 5 |
| 2008 | 2 | — | 2 | 25 |
| 2009 | 2 | — | 0 | 19 |
| 2010 | 0 | — | 2 | 28 |
| 2011 | 6 | 130 | 0 | 30 |
| 2012 | 3 | 134 | 0 | 130 |
| 2013 | 1 | — | 1 | 321 |
| 2014 | 2 | — | 0 | 223 |
| 2015 | 5 | 92 | 1 | 205 |
| 2016 | 4 | 129 | 0 | 224 |
| 2017 | 1 | — | 0 | 138 |
| 2018 | 6 | 101 | 0 | 182 |
| 2019 | 0 | — | 5 | 158 |
| 2020 | 4 | 93 | 0 | 125 |
| 2021 | 0 | — | 0 | 141 |
| 2022 | 2 | — | 0 | 134 |
| 2023 | 3 | 141 | 0 | 98 |
| 2024 | 3 | 130 | 0 | 115 |
| 2025 | 2 | — | 0 | 84 |
| 2026 | 1 | — | 0 | — |
https://510kreport.com/device/K932024 · printed Nov 6, 2026
Cite this page
510(k) Report. “K932024: CCG Cerclage System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K932024
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026