Medisystems Corp. · FIE Needle, Fistula

Cleared on Feb 18, 1994 after a 296-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 8 later devices descend from it.

Decided
Feb 18, 1994
Review
296 days
Class
Class II
Product code
FIE
Recalls
None
Predicates
0

8 later devices descend from it, 4 citing it directly.

Descendants, by year cleared 2010: 1 descendant cleared2007: 1 descendant cleared2008: 1 descendant cleared1999: 1 descendant cleared2018: 2 descendants cleared2017: 1 descendant cleared2022: 1 descendant cleared1990200020102020
  1. This deviceK932074 Medisystems Apheresis Needle with GuardMedisystems Corp. · 1994
  2. Descendant · cites it directly · 3 of its ownK071145 Nipro Safetouch Tulip Safety Fistula NeedleNipro Medical Corporation · 2007 · Recalled
  3. Descendant · cites it directly · 2 of its ownK073257 Kawasumi Laboratories Large Wing Sets with Antineedle Stick ProtectorKawasumi Laboratories, Inc. · 2008
  4. Descendant · 2 generations on · 1 of its ownK163025 DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd. · 2017
  5. Descendant · cites it directly · 1 of its ownK102994 K-Shield Arterial Venous Fistula Set with Antineedle Stick ProtectorKawasumi Laboratories, Inc. · 2010
  6. Descendant · 3 generations on · 0 of its ownK213015 DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd. · 2022

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

1999: 12007: 12008: 12010: 12017: 12018: 22022: 1
1999high 2 (2018) · low 0 (2000)2026

Most influential descendants

Showing 5 of 8 · See all
  • K071145Nipro Safetouch Tulip Safety Fistula NeedleNipro Medical Corporation · 2007 · cites it directly3descendants
  • K073257Kawasumi Laboratories Large Wing Sets with Antineedle Stick ProtectorKawasumi Laboratories, Inc. · 2008 · cites it directly2descendants
  • K163025DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd. · 2017 · 2 generations on1descendant
  • K102994K-Shield Arterial Venous Fistula Set with Antineedle Stick ProtectorKawasumi Laboratories, Inc. · 2010 · cites it directly1descendant
  • K213015DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd. · 2022 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K932074Medisystems Apheresis Needle with GuardMedisystems Corp.1994—
+1K071145Nipro Safetouch Tulip Safety Fistula NeedleNipro Medical Corporation20071
+1K073257Kawasumi Laboratories Large Wing Sets with Antineedle Stick ProtectorKawasumi Laboratories, Inc.2008—
+2K163025DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd.2017—
+1K102994K-Shield Arterial Venous Fistula Set with Antineedle Stick ProtectorKawasumi Laboratories, Inc.2010—
+3K213015DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd.2022—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200710
200810
201010
201710
201820
202210
FIG. 1 — Lineage of K932074, 1994–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FIE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FIE device

  1. #1 K253469 Ritus™ Safety Fistula Cannula with Anti-Reflux…score 13.0 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.

What descends from it? (8)

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071145Nipro Safetouch Tulip Safety Fistula NeedleNipro Medical Corporation20073
K073257Kawasumi Laboratories Large Wing Sets with Antineedle Stick ProtectorKawasumi Laboratories, Inc.20082
K102994K-Shield Arterial Venous Fistula Set with Antineedle Stick ProtectorKawasumi Laboratories, Inc.20101
K991404Platypus AV Fistula Needle Protector (Avfnp)Itl Corporation Pty, Ltd.19990

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K071145 (Nipro Medical Corporation, 2007) has gone furthest, with 3 descendants of its own.

How does its category compare?

All FIE devices

FIE Needle, Fistula: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FIE

1in 2025

2007: 32009: 12010: 32011: 32012: 12014: 22015: 22017: 12018: 12022: 12025: 12026 (partial year): 1
2007high 3 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FIE

91in 2011

2007: 90 days median2010: 29 days median2011: 91 days median
2007high 91 (2011) · low 29 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FIE

3in 2012

2012: 3
2007high 3 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FIE

33in 2025

2007: 132008: 102009: 272010: 172011: 22012: 72013: 62014: 42015: 232016: 212017: 142018: 162019: 212020: 32021: 12022: 12023: 582024: 142025: 33
2007high 58 (2023) · low 1 (2021)2025

MAUDE reports naming product code FIE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007390013
20080—010
20091—027
2010329017
201139102
20121—37
20130—06
20142—04
20152—023
20160—021
20171—014
20181—016
20190—021
20200—03
20210—01
20221—01
20230—058
20240—014
20251—033
20261—0—
Cite this page

510(k) Report. “K932074: Medisystems Apheresis Needle with Guard.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K932074

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026