510(k) Report

510(k) · Cleared

Recalled · Class II · 2014

Vacutainer Brand PST Plasma Separation Tube

K954592510(k) TraditionalCleared Nov 28, 199557-day reviewClass II21 CFR 862.1675Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton Dickinson Vacutainer Systems · JKA Tubes, Vials, Systems, Serum Separators, Blood Collection

Cleared on Nov 28, 1995 after a 57-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 1 of the 2 devices in its family, counting itself, has a Class I recall. 1 later device descends from it. It has been recalled once.

Decided
Nov 28, 1995
Review
57 days
Class
Class II
Product code
JKA
Recalls
1
Predicates
0

1 later device descends from it, 1 citing it directly. 1 of the 2 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2016: 1 descendant cleared, 1 with a Class I recall11995200020052010201520202025
  1. This deviceK954592 Vacutainer Brand PST Plasma Separation TubeBecton Dickinson Vacutainer Systems · 1995
  2. Descendant · cites it directly · 0 of its ownK160657 BD Vacutainer Barricor Lithium Heparin Plasma Blood Collection TubeBecton, Dickinson and Company · 2016 · Recalled (Class I)

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K160657BD Vacutainer Barricor Lithium Heparin Plasma Blood Collection TubeBecton, Dickinson and Company · 2016 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K954592Vacutainer Brand PST Plasma Separation TubeBecton Dickinson Vacutainer Systems1995—
+1K160657BD Vacutainer Barricor Lithium Heparin Plasma Blood Collection TubeBecton, Dickinson and Company2016Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201611
FIG. 1 — Lineage of K954592, 1995–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JKA device

  1. #1 K200027 Blood Collection Needle with/without Holder…score 15.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K160657BD Vacutainer Barricor Lithium Heparin Plasma Blood Collection Tube Class IBecton, Dickinson and Company20160

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 23, 2014Class IIZ-2634-2014StorageProducts were held at improper storage temperature

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K160657BD Vacutainer Barricor Lithium Heparin Plasma Blood Collection TubeBecton, Dickinson and Company · 2016 · Cites it directly · ◆ in the 2016 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Of its descendants, K160657 (Becton, Dickinson and Company, 2016) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JKA devices

JKA Tubes, Vials, Systems, Serum Separators, Blood Collection: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JKA

7in 2025

2007: 42008: 22009: 22010: 42012: 12013: 32014: 12015: 12016: 42017: 22018: 12019: 62020: 62021: 42022: 92023: 172024: 62025: 72026 (partial year): 8
2007high 17 (2023) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JKA

115in 2025

2007: 281 days median2010: 28 days median2013: 244 days median2016: 116 days median2019: 181 days median2020: 181 days median2021: 217 days median2022: 164 days median2023: 189 days median2024: 240 days median2025: 115 days median2026 (partial year): 250 days median
2007high 281 (2007) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JKA

13in 2025

2007: 32008: 32009: 32010: 42011: 142012: 22013: 12014: 12015: 62016: 12017: 22018: 22019: 92021: 32022: 22023: 22025: 132026 (partial year): 1
2007high 14 (2011) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JKA

6,089in 2025

2007: 732008: 782009: 422010: 372011: 672012: 542013: 332014: 682015: 412016: 652017: 2,0392018: 9,7312019: 6,4692020: 3,7742021: 3,6102022: 3,3752023: 4,4002024: 4,6092025: 6,089
2007high 9,731 (2018) · low 33 (2013)2025

MAUDE reports naming product code JKA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074281373
20082—378
20092—342
2010428437
20110—1467
20121—254
20133244133
20141—168
20151—641
20164116165
20172—22,039
20181—29,731
2019618196,469
2020618103,774
2021421733,610
2022916423,375
20231718924,400
2024624004,609
20257115136,089
202682501—
Cite this page

510(k) Report. “K954592: Vacutainer Brand PST Plasma Separation Tube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K954592

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026