510(k) Report

510(k) · Cleared

Cleared

Surface Electromyograph Biofeedback Muscle Activity Device

K954737510(k) TraditionalCleared Jul 3, 1996261-day reviewClass II21 CFR 882.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

J-Tech, Inc. · HCC Device, Biofeedback

Cleared on Jul 3, 1996 as substantially equivalent to K912938 (Stellate Systems, 1991) and 1 other predicate after a 261-day review. Its family tree reaches back 1 generation to 1991.

Decided
Jul 3, 1996
Review
261 days
Class
Class II
Product code
HCC
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K912938 (1991). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1995: 1 other ancestorK912938 · Rhythm · Stellate Systems · 199119901992199419961998
Other ancestors, by generation 1 generation back: 1 other ancestor K912938 · Rhythm · Stellate Systems · 19910
  1. Root · 1 generation backK912938 RhythmStellate Systems · 1991
  2. This deviceK954737 Surface Electromyograph Biofeedback Muscle Activity DeviceJ-Tech, Inc. · 1996
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K912938RhythmStellate Systems1991—
0 (this device)K954737Surface Electromyograph Biofeedback Muscle Activity DeviceJ-Tech, Inc.1996—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
FIG. 1 — Lineage of K954737, 1991–1996Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HCC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HCC device

  1. #1 K233580 A Breathing System (ABS)score 8.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K912938Rhythm
Summary page 1
…12.1 ldentification of Legally Marketed Device The JTech Dynatrack SEMG System is substantially equivalent to the class Il Targus Concepts Biostar SEMG System Device (K912938), the Tracker Microprocessor, and the Tracker PC Software of the Large Muscle Strength Gauge (K944630). 12.2 JTech Dynatrack SE…
Stellate Systems1991—
*K945630Large Muscle Strength Gauge
Our OCR of the scanned summary read K944630, FDA’s number for Model 230-Sas Laser Delivery Probe (Mnlase, Inc.). Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “Tracker Microprocessor and Tracker PC Software of the Large Muscle…”.
J-Tech, Inc.1995—

Also cleared against K912938: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • 2 other devices also cite its predicate K912938.

How does its category compare?

All HCC devices

HCC Device, Biofeedback: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HCC

1in 2024

2007: 12008: 22010: 12011: 12013: 22015: 22017: 12018: 12023: 12024: 1
2007high 2 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HCC

Too few HCC 510(k)s in any year since 2007 to give a median.

Recalls per year · HCC

1in 2015

2012: 12015: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HCC

5in 2024

2007: 22008: 22009: 12011: 42012: 22013: 22014: 22016: 42017: 32018: 12019: 62020: 22022: 32023: 22024: 5
2007high 6 (2019) · low 0 (2010)2025

MAUDE reports naming product code HCC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—02
20082—02
20090—01
20101—00
20111—04
20120—12
20132—02
20140—02
20152—10
20160—04
20171—03
20181—01
20190—06
20200—02
20210—00
20220—03
20231—02
20241—05
20250—00
20260—0—

What is it indicated for?

The JTech Dynatrack Surface Electromyograph is a biofeedback device that provides a visual signal corresponding to the status of a patient’s muscle activity. Healthcare professionals can use the machine to monitor the patient’s muscle activity. This is a precise biofeedback instrument for quick and accurate assessment and recording of the bioelectric muscie signal. It is compliant with the National Bureau of Standards calibration standards for microvolts.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K954737: Surface Electromyograph Biofeedback Muscle Activity Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K954737

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026