510(k) Report

510(k) · Cleared

Recalled · 2009

Siregraph CF

K960266510(k) TraditionalCleared Mar 11, 199653-day reviewClass II21 CFR 892.1650Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Medical Solutions USA, Inc. · JAA System, X-Ray, Fluoroscopic, Image-Intensified

Cleared on Mar 11, 1996 as substantially equivalent to K951358 (Siemens Medical Solutions USA, Inc., 1995) and 2 other predicates after a 53-day review. Its family tree reaches back 1 generation to 1991. 132 later devices descend from it. It has been recalled 3 times.

Decided
Mar 11, 1996
Review
53 days
Class
Class II
Product code
JAA
Recalls
3
Predicates
3

Its longest line of descent runs back 1 generation to K912470 (1991). 3 ancestors in all. 132 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1995: 1 other ancestor1993: 1 other ancestor1997: 1 descendant cleared1999: 1 descendant cleared2004: 1 descendant cleared2007: 2 descendants cleared2005: 2 descendants cleared2006: 1 descendant cleared2011: 4 descendants cleared2008: 3 descendants cleared2010: 5 descendants cleared2015: 5 descendants cleared2013: 3 descendants cleared2009: 1 descendant cleared2018: 9 descendants cleared2014: 5 descendants cleared2022: 8 descendants cleared2019: 11 descendants cleared2012: 4 descendants cleared2017: 3 descendants cleared2016: 7 descendants cleared2024: 6 descendants cleared2025: 11 descendants cleared2021: 11 descendants cleared2020: 13 descendants cleared2023: 7 descendants cleared2026: 8 descendants clearedK912470 · Philips Diagnost 96 · Philips Medical Systems, Inc. · 1991 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 3 descendants4 generations forward: 14 descendants5 generations forward: 24 descendants6 generations forward: 33 descendants7 generations forward: 25 descendants8 generations forward: 19 descendants9 generations forward: 5 descendants10 generations forward: 2 descendants11 generations forward: 2 descendants12 generations forward: 3 descendants K912470 · Philips Diagnost 96 · Philips Medical Systems, Inc. · 1991 · recalled0+5+10
  1. Root · 1 generation backK912470 Philips Diagnost 96Philips Medical Systems, Inc. · 1991 · Recalled
  2. This deviceK960266 Siregraph CFSiemens Medical Solutions USA, Inc. · 1996
  3. Descendant · cites it directly · 131 of its ownK970734 Siregragh T.O.P. 33 and Siregraph T.O.P. 40 Universal Fluoroscopic…Siemens Medical Solutions USA, Inc. · 1997
  4. Descendant · 2 generations on · 130 of its ownK992660 Urf Digital - OTSiemens Medical Solutions USA, Inc. · 1999 · Recalled
  5. Descendant · 3 generations on · 78 of its ownK062623 Axiom Luminos DRFSiemens Medical Solutions USA, Inc. · 2007 · Recalled
  6. Descendant · 3 generations on · 49 of its ownK040675 Axiom Artis USiemens Medical Systems, Inc. · 2004 · Recalled
  7. Descendant · 4 generations on · 43 of its ownK081722 YSIOSiemens Medical Solutions USA, Inc. · 2008 · Recalled

Showing 5 of 132 descendants. See all descendants

Descendants cleared per year

1997: 11999: 12004: 12005: 22006: 12007: 22008: 32009: 12010: 52011: 42012: 42013: 32014: 52015: 52016: 72017: 32018: 92019: 112020: 132021: 112022: 82023: 72024: 62025: 112026: 8
1997high 13 (2020) · low 0 (1998)2026

Most influential descendants

Showing 5 of 132 · See all
  • K970734Siregragh T.O.P. 33 and Siregraph T.O.P. 40 Universal Fluoroscopic X-Ray SystemsSiemens Medical Solutions USA, Inc. · 1997 · cites it directly131descendants
  • K992660Urf Digital - OTSiemens Medical Solutions USA, Inc. · 1999 · 2 generations on130descendants
  • K062623Axiom Luminos DRFSiemens Medical Solutions USA, Inc. · 2007 · 3 generations on78descendants
  • K040675Axiom Artis USiemens Medical Systems, Inc. · 2004 · 3 generations on49descendants
  • K081722YSIOSiemens Medical Solutions USA, Inc. · 2008 · 4 generations on43descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K912470Philips Diagnost 96Philips Medical Systems, Inc.19919
0 (this device)K960266Siregraph CFSiemens Medical Solutions USA, Inc.1996—
+1K970734Siregragh T.O.P. 33 and Siregraph T.O.P. 40 Universal Fluoroscopic X-Ray SystemsSiemens Medical Solutions USA, Inc.1997—
+2K992660Urf Digital - OTSiemens Medical Solutions USA, Inc.19994
+3K062623Axiom Luminos DRFSiemens Medical Solutions USA, Inc.200720
+3K040675Axiom Artis USiemens Medical Systems, Inc.20041
+4K081722YSIOSiemens Medical Solutions USA, Inc.200811

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199710
199910
200410
200520
200610
200720
200830
200910
201050
201140
201240
201330
201450
201550
201670
201730
201890
2019110
2020130
2021110
202280
202370
202460
2025110
202680
FIG. 1 — Lineage of K960266, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAA device

  1. #1 K253103 Nexus DRF Digital X-ray Imaging Systemscore 13.2 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K951358Sireskop SX
Summary page 2
…is substantially equivalent to the following medical devices currently in commercial distribution. Model Company FDA K-Number Sireskop SX Siemens Medical Systems, Inc. K951358 Prestilix 1600X GE Medical Systems K924310 Diagnost 96 Philip Medical Systems K912470 (/16 Z 76 Kathleen Rutherford Date / Manag…
Siemens Medical Solutions USA, Inc.19952
*K924310Prestilix 1694 D Image Intensified Fluorosccopic
Summary page 2
…g medical devices currently in commercial distribution. Model Company FDA K-Number Sireskop SX Siemens Medical Systems, Inc. K951358 Prestilix 1600X GE Medical Systems K924310 Diagnost 96 Philip Medical Systems K912470 (/16 Z 76 Kathleen Rutherford Date / Manager, Regulatory Submissions
GE Medical Systems19931
*K912470Philips Diagnost 96
Summary page 2
…istribution. Model Company FDA K-Number Sireskop SX Siemens Medical Systems, Inc. K951358 Prestilix 1600X GE Medical Systems K924310 Diagnost 96 Philip Medical Systems K912470 (/16 Z 76 Kathleen Rutherford Date / Manager, Regulatory Submissions
Philips Medical Systems, Inc.19919

Also cleared against K951358: 1 other device →

What descends from it? (132)

See all 132

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K970734Siregragh T.O.P. 33 and Siregraph T.O.P. 40 Universal Fluoroscopic X-Ray SystemsSiemens Medical Solutions USA, Inc.1997131

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 23, 2009Not classifiedZ-0189-2010Device Designpossible injury to hand/fingers
Jun 7, 2004Not classifiedZ-1475-04OtherX-ray tube movement when table is tilted more than 90 degrees
Jun 7, 2004Not classifiedZ-1476-04OtherX-ray tube movement when table is tilted more than 90 degrees

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 3 of the 3 ancestors have a recall of any class.
  • Of its descendants, K970734 (Siemens Medical Solutions USA, Inc., 1997) has gone furthest, with 131 descendants of its own.
  • 1 other device also cites its predicate K951358.

How does its category compare?

All JAA devices

JAA System, X-Ray, Fluoroscopic, Image-Intensified: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JAA

2in 2025

2007: 12008: 62010: 12011: 42012: 12013: 62014: 62015: 32016: 22017: 12018: 32019: 62020: 42021: 62022: 12023: 22024: 32025: 22026 (partial year): 1
2007high 6 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAA

89in 2024

2008: 18 days median2011: 48 days median2013: 129 days median2014: 276 days median2015: 197 days median2018: 30 days median2019: 49 days median2020: 39 days median2021: 104 days median2024: 89 days median
2007high 276 (2014) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAA

4in 2025

2007: 352008: 212009: 182010: 62011: 72012: 22013: 32014: 12015: 12016: 72017: 32018: 12019: 22020: 22021: 22022: 52023: 92024: 22025: 4
2007high 35 (2007) · low 1 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAA

33in 2025

2007: 9,5172008: 9,4842009: 12,0402010: 5,8032011: 14,0002012: 11,6842013: 13,7062014: 10,2652015: 2,9222016: 352017: 562018: 362019: 492020: 392021: 352022: 342023: 412024: 252025: 33
2007high 14,000 (2011) · low 25 (2024)2025

MAUDE reports naming product code JAA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—359,517
2008618219,484
20090—1812,040
20101—65,803
2011448714,000
20121—211,684
20136129313,706
20146276110,265
2015319712,922
20162—735
20171—356
2018330136
2019649249
2020439239
20216104235
20221—534
20232—941
2024389225
20252—433
20261—0—

What is it indicated for?

The Siemens Siregraph CF is a remote overtable radiographic/fluoroscopic x-ray diagnostic system that was designed for universal implementation in the hospital and clinical environment. The Siregraph CF, remote X-ray system, has medical applications ranging from gastrointestinal examinations to cranial, skeletal, thoraic and lung exposures as well as examinations of the urinary tract, lymphography, myelography, venography, arthrography angiography and DSA.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K960266: Siregraph CF.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K960266

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026