510(k) Report

510(k) · Cleared

Cleared

Preclude Ima Sleeve

K960532510(k) TraditionalCleared May 23, 1996106-day reviewClass II21 CFR 870.3470

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

W. L. Gore & Associates, Inc. · MFX Vessel Guard Or Cover, To Facilitate Revision Surgeries

Cleared on May 23, 1996 after a 106-day review. The FDA summary names its predicate without a number. 5 later devices descend from it.

Decided
May 23, 1996
Review
106 days
Class
Class II
Product code
MFX
Recalls
None
Predicates
0

5 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2010: 2 descendants cleared2011: 1 descendant cleared2012: 1 descendant cleared1995200020052010201520202025
  1. This deviceK960532 Preclude Ima SleeveW. L. Gore & Associates, Inc. · 1996
  2. Descendant · cites it directly · 3 of its ownK082782 Replication Medical Vessel GuardReplication Medical, Inc. · 2009
  3. Descendant · 2 generations on · 1 of its ownK103558 Synthes Scout Vessel GuardSynthes Spine · 2011
  4. Descendant · 2 generations on · 0 of its ownK111048 Synthes Scout Tack FixationSynthes Spine · 2012
  5. Descendant · cites it directly · 0 of its ownK100984 Xylos Vessel GuardXylos Corporation · 2010
  6. Descendant · cites it directly · 0 of its ownK090637 Cardio-WrapMast Biosurgery USA, Inc. · 2010

Most influential descendants

Showing 5 of 5 · See all
  • K082782Replication Medical Vessel GuardReplication Medical, Inc. · 2009 · cites it directly3descendants
  • K103558Synthes Scout Vessel GuardSynthes Spine · 2011 · 2 generations on1descendant
  • K111048Synthes Scout Tack FixationSynthes Spine · 2012 · 2 generations on0descendants
  • K100984Xylos Vessel GuardXylos Corporation · 2010 · cites it directly0descendants
  • K090637Cardio-WrapMast Biosurgery USA, Inc. · 2010 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K960532Preclude Ima SleeveW. L. Gore & Associates, Inc.1996—
+1K082782Replication Medical Vessel GuardReplication Medical, Inc.2009—
+2K103558Synthes Scout Vessel GuardSynthes Spine2011—
+2K111048Synthes Scout Tack FixationSynthes Spine2012—
+1K100984Xylos Vessel GuardXylos Corporation2010—
+1K090637Cardio-WrapMast Biosurgery USA, Inc.2010—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201020
201110
201210
FIG. 1 — Lineage of K960532, 1996–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MFX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—PRECLUDE™ Pericardial Membrane
Named without a submission number
—

What descends from it? (5)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K082782Replication Medical Vessel GuardReplication Medical, Inc.20093
K100984Xylos Vessel GuardXylos Corporation20100
K090637Cardio-WrapMast Biosurgery USA, Inc.20100

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K082782 (Replication Medical, Inc., 2009) has gone furthest, with 3 descendants of its own.

How does its category compare?

All MFX devices

MFX Vessel Guard Or Cover, To Facilitate Revision Surgeries: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MFX

FDA has decided no MFX device since 2007.

Median 510(k) review, days · MFX

Too few MFX 510(k)s in any year since 2007 to give a median.

Recalls per year · MFX

No recall names MFX since 2007.

Adverse event reports per year · MFX

1in 2010

2007: 32008: 72010: 1
2007high 7 (2008) · low 0 (2009)2025

MAUDE reports naming product code MFX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20080—07
20090—00
20100—01
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

For use as a wrap for pedicled arterial conduits.

The device identifies and protects pedicled arterial conduits during reoperative cardiac surgery.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K960532: Preclude Ima Sleeve.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K960532

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026