510(k) · Cleared
ClearedFoundation Glenoid Component
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Encore Orthopedics, Inc. · KWS Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
Cleared on Apr 15, 1996 after a 41-day review. The FDA summary names its predicate without a number. 86 later devices descend from it.
- Decided
- Apr 15, 1996
- Review
- 41 days
- Class
- Class II
- Product code
- KWS
- Recalls
- None
- Predicates
- 0
86 later devices descend from it, 2 citing it directly.
- This deviceK960906 Foundation Glenoid ComponentEncore Orthopedics, Inc. · 1996
- Descendant · cites it directly · 71 of its ownK042021 Exactech Equinoxe Shoulder SystemExactech, Inc. · 2004 · Recalled
- Descendant · 2 generations on · 24 of its ownK093430 Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech…Exactech, Inc. · 2010 · Recalled
- Descendant · 2 generations on · 22 of its ownK103419 Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TMExactech, Inc. · 2010 · Recalled
- Descendant · 3 generations on · 21 of its ownK111379 Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium…Exactech, Inc. · 2011 · Recalled
- Descendant · 4 generations on · 20 of its ownK121220 Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small…Exactech, Inc. · 2012 · Recalled
Showing 5 of 86 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 86 · See all- K042021Exactech Equinoxe Shoulder SystemExactech, Inc. · 2004 · cites it directly71descendants
- K093430Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech Equinoxe Cage, Glenoid…Exactech, Inc. · 2010 · 2 generations on24descendants
- K103419Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TMExactech, Inc. · 2010 · 2 generations on22descendants
- K111379Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium / Large /…Exactech, Inc. · 2011 · 3 generations on21descendants
- K121220Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small, Left/RightExactech, Inc. · 2012 · 4 generations on20descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K960906 | Foundation Glenoid Component | Encore Orthopedics, Inc. | 1996 | — |
| +1 | K042021 | Exactech Equinoxe Shoulder System | Exactech, Inc. | 2004 | 10 |
| +2 | K093430 | Exactech Equinoxe XL Keeled Glenoid, Pegged Glenoid, Exactech Equinoxe Cage… | Exactech, Inc. | 2010 | 1 |
| +2 | K103419 | Exactech Equinoxe R Uhmwpe Posterior Augment Pegged Glenoids TM | Exactech, Inc. | 2010 | 2 |
| +3 | K111379 | Equinoxe Uhmwpe 12* Posterior Augment Pegged Glenoid, Small / Medium / Large /… | Exactech, Inc. | 2011 | 2 |
| +4 | K121220 | Equinoxe Glenoid, Uhmwpe 16 PS=Osterior Augment Pegged, Small, Left/Right | Exactech, Inc. | 2012 | 2 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
| 2006 | 2 | 0 |
| 2010 | 6 | 0 |
| 2011 | 4 | 0 |
| 2012 | 3 | 0 |
| 2013 | 2 | 0 |
| 2014 | 2 | 0 |
| 2015 | 4 | 0 |
| 2016 | 4 | 0 |
| 2017 | 3 | 0 |
| 2018 | 8 | 0 |
| 2019 | 5 | 0 |
| 2020 | 1 | 0 |
| 2021 | 3 | 0 |
| 2022 | 7 | 0 |
| 2023 | 8 | 0 |
| 2024 | 7 | 0 |
| 2025 | 10 | 0 |
| 2026 | 6 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWS device
- #1 K220847 AETOS Shoulder Systemscore 21.1 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Encore Foundation™ Total Shoulder System Named without a submission number | |
| * | — | Kirshner Neer II™ Glenoid Component Named without a submission number | |
| * | — | Intermedics Select™ Shoulder Glenoid Component Named without a submission number |
What descends from it? (86)
See all 862 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K042021 (Exactech, Inc., 2004) has gone furthest, with 71 descendants of its own.
How does its category compare?
All KWS devicesKWS Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWS
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KWS
97in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWS
2in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWS
2,281in 2025
MAUDE reports naming product code KWS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 21 | 158 |
| 2008 | 4 | 37 | 29 | 238 |
| 2009 | 4 | 108 | 0 | 294 |
| 2010 | 7 | 33 | 10 | 393 |
| 2011 | 11 | 90 | 11 | 486 |
| 2012 | 7 | 86 | 10 | 542 |
| 2013 | 12 | 120 | 0 | 818 |
| 2014 | 7 | 89 | 1 | 1,066 |
| 2015 | 8 | 129 | 0 | 1,170 |
| 2016 | 10 | 114 | 1 | 970 |
| 2017 | 7 | 120 | 4 | 1,681 |
| 2018 | 4 | 152 | 1 | 1,545 |
| 2019 | 9 | 106 | 2 | 1,728 |
| 2020 | 3 | 98 | 5 | 1,567 |
| 2021 | 5 | 151 | 0 | 1,358 |
| 2022 | 5 | 158 | 0 | 1,268 |
| 2023 | 4 | 250 | 2 | 1,750 |
| 2024 | 2 | — | 0 | 2,122 |
| 2025 | 3 | 97 | 0 | 2,281 |
| 2026 | 2 | — | 1 | — |
What is it indicated for?
This total shoulder prosthesis is intended for treatment of patients who are candidates for total shoulder arthroplasty because the natural humeral head and/or glenoid has been affected by osteoarthritis, inflammatory arthritis, traumatic arthritis, rheumatoid arthritis, avascular necrosis or proximal humeral fracture, and revision arthroplasty where bone loss is minimal. This system includes a humeral stem and head and is to be used with bone cement. These devices are intended to aid the surgeon in relieving the patient of shoulder pain and restoring shoulder motion.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K960906 · printed Nov 6, 2026
Cite this page
510(k) Report. “K960906: Foundation Glenoid Component.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K960906
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026