510(k) · Cleared
ClearedSiemens Beam Shaper
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Siemens Medical Solutions USA, Inc. · IXI Block, Beam-Shaping, Radiation Therapy
Cleared on Aug 8, 1996 as substantially equivalent to K953894 (Siemens Medical Solutions USA, Inc., 1995) after an 84-day review. Its family tree reaches back 1 generation to 1995. 1 later device descends from it.
- Decided
- Aug 8, 1996
- Review
- 84 days
- Class
- Class II
- Product code
- IXI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K953894 (1995). 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K982952ImfastSiemens Medical Solutions USA, Inc. · 1999 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K953894 | Siemens Multileaf Collimator | Siemens Medical Solutions USA, Inc. | 1995 | — |
| 0 (this device) | K961902 | Siemens Beam Shaper | Siemens Medical Solutions USA, Inc. | 1996 | — |
| +1 | K982952 | Imfast | Siemens Medical Solutions USA, Inc. | 1999 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IXI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IXI device
- #1 K253025 Ricoh 3D for Healthcare Bolusscore 12.9 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K953894 | Siemens Multileaf CollimatorSummary page 1…ssification Names: Radiation therapy beam shaping block - 21 CFR § 892.5710 Class II, Product Code: RA 90 IXI Predicate Device: Siemens Multileaf Collimator Hand Control K953894 Description of Device: Beam Shaper consists of a digitizer tablet for inputting leaf positions based on field shapes traced from… | 1995 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K982952 | Imfast | 1999 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All IXI devicesIXI Block, Beam-Shaping, Radiation Therapy: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · IXI
2in 2022
2026 to Oct 25, outlined.
Median 510(k) review, days · IXI
90in 2013
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IXI
2in 2013
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · IXI
1in 2016
MAUDE reports naming product code IXI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 0 | — | 1 | 0 |
| 2009 | 3 | 78 | 0 | 0 |
| 2010 | 0 | — | 0 | 1 |
| 2011 | 2 | — | 1 | 28 |
| 2012 | 1 | — | 1 | 3 |
| 2013 | 3 | 90 | 2 | 2 |
| 2014 | 0 | — | 0 | 1 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 1 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 2 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The MLC Beam Shaper software utility provides the ability to create, view, and edit geometric information that will be utilized to form irregular treatment fields through automated changes of multiple leaves that conform to the specified treatment target generate treatment field shapes. The MLC Beam Shaper software is an accessory to the Siemens Multileaf Collimator with Lantis Record and Verify System for the Siemens Digital MEVATRON radiation treatment system.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K961902 · printed Nov 4, 2026
Cite this page
510(k) Report. “K961902: Siemens Beam Shaper.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K961902
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026