510(k) · Cleared
ClearedImfast
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Siemens Medical Solutions USA, Inc. · LHN System, Radiation Therapy, Charged-Particle, Medical
Cleared on Mar 5, 1999 as substantially equivalent to K961902 (Siemens Medical Solutions USA, Inc., 1996) after a 193-day review. Its family tree reaches back 2 generations to 1995.
- Decided
- Mar 5, 1999
- Review
- 193 days
- Class
- Class II
- Product code
- LHN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K953894 (1995). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LHN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LHN device
- #1 K260597 Virtue QAscore 15.4 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K961902 | Siemens Beam ShaperSummary page 1…ary Name: IMFAST Classification Name: Radiation therapy beam shaping block 21 CFR § 892.5710 Class 11, Product Code: RA 90 IXI Predicate Device: BeamShaper, 510(k) No. K961902 Description of Device: IMFAST is a MLC optimization algorithm that sets the MLC jaws for modulated intensity profiles, thereby e… | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 4 years and passes through 1 company; a new generation was cleared every 2.6 years on median.
- None of the 2 ancestors has a recall.
How does its category compare?
All LHN devicesLHN System, Radiation Therapy, Charged-Particle, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LHN
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LHN
190in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LHN
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LHN
11in 2025
MAUDE reports naming product code LHN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 2 | 0 |
| 2008 | 3 | 113 | 2 | 1 |
| 2009 | 5 | 69 | 0 | 5 |
| 2010 | 4 | 96 | 0 | 3 |
| 2011 | 1 | — | 0 | 1 |
| 2012 | 3 | 111 | 0 | 1 |
| 2013 | 3 | 70 | 0 | 1 |
| 2014 | 4 | 93 | 2 | 5 |
| 2015 | 3 | 53 | 1 | 2 |
| 2016 | 7 | 120 | 0 | 1 |
| 2017 | 4 | 173 | 5 | 7 |
| 2018 | 3 | 78 | 2 | 8 |
| 2019 | 2 | — | 0 | 3 |
| 2020 | 4 | 74 | 1 | 20 |
| 2021 | 0 | — | 1 | 24 |
| 2022 | 2 | — | 2 | 10 |
| 2023 | 2 | — | 1 | 7 |
| 2024 | 1 | — | 0 | 2 |
| 2025 | 3 | 190 | 0 | 11 |
| 2026 | 4 | 194 | 0 | — |
What is it indicated for?
The IMFAST product is intended to calculate a sequence of multi-leaf collimator (MLC) segments. These resulting segments are then written to a file, allowing the V&R system or the RTP system to pick it up for further processing. In the case of SIEMENS' LANTIS and PRIMEVIEW, the file can be imported and the segments can be grouped into intensity modulation groups. The treatment can then be delivered in sequence using SIMTEC and an MLC, thus providing the patient with automated, computer-controlled intensity modulation radiotherapy (IMRT).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982952 · printed Nov 5, 2026
Cite this page
510(k) Report. “K982952: Imfast.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K982952
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026