510(k) · Cleared
Recalled · 2002Scimed Choice PT Vision Ptca Guide Wire
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Scimed Life Systems, Inc. · DQX Wire, Guide, Catheter
Cleared on Dec 17, 1996 as substantially equivalent to K943192 (Scimed Life Systems, Inc., 1994) and 8 other predicates after a 169-day review. Its family tree reaches back 1 generation to 1994. 16 later devices descend from it. It has been recalled 3 times.
- Decided
- Dec 17, 1996
- Review
- 169 days
- Class
- Class II
- Product code
- DQX
- Recalls
- 3
- Predicates
- 9
Its longest line of descent runs back 1 generation to K941895 (1994). 9 ancestors in all. 16 later devices descend from it, 3 citing it directly.
- Root · 1 generation backK941895 Scimed 0.014 Ptca Guide Wire with Ice Hydrophilic CoatingScimed Life Systems, Inc. · 1994
- This deviceK962572 Scimed Choice PT Vision Ptca Guide WireScimed Life Systems, Inc. · 1996
- Descendant · cites it directly · 11 of its ownK030617 PT2 Guide Wire and Addwire Extension WireBoston Scientific Scimed, Inc. · 2003 · Recalled
- Descendant · 2 generations on · 6 of its ownK143587 ChoICE Guide Wire, Mailman Guide Wire, Luge Guide Wire, ChoICE PT…Boston Scientific Corporation · 2015 · Recalled
- Descendant · 2 generations on · 4 of its ownK032183 IQ Hydrophilic Guide WireBoston Scientific Corp · 2003
- Descendant · 3 generations on · 3 of its ownK040140 IQ Guide WireBoston Scientific Corp · 2004 · Recalled
- Descendant · 3 generations on · 2 of its ownK152231 Hornet Guidewire, Hornet 10 Guidewire, Hornet 14 GuidewireBoston Scientific Corporation · 2016
Showing 5 of 16 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 16 · See all- K030617PT2 Guide Wire and Addwire Extension WireBoston Scientific Scimed, Inc. · 2003 · cites it directly11descendants
- K143587ChoICE Guide Wire, Mailman Guide Wire, Luge Guide Wire, ChoICE PT Guide Wire, PT Graphix…Boston Scientific Corporation · 2015 · 2 generations on6descendants
- K032183IQ Hydrophilic Guide WireBoston Scientific Corp · 2003 · 2 generations on4descendants
- K040140IQ Guide WireBoston Scientific Corp · 2004 · 3 generations on3descendants
- K152231Hornet Guidewire, Hornet 10 Guidewire, Hornet 14 GuidewireBoston Scientific Corporation · 2016 · 3 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K941895 | Scimed 0.014 Ptca Guide Wire with Ice Hydrophilic Coating | Scimed Life Systems, Inc. | 1994 | — |
| 0 (this device) | K962572 | Scimed Choice PT Vision Ptca Guide Wire | Scimed Life Systems, Inc. | 1996 | — |
| +1 | K030617 | PT2 Guide Wire and Addwire Extension Wire | Boston Scientific Scimed, Inc. | 2003 | 4 |
| +2 | K143587 | ChoICE Guide Wire, Mailman Guide Wire, Luge Guide Wire, ChoICE PT Guide Wire… | Boston Scientific Corporation | 2015 | 1 |
| +2 | K032183 | IQ Hydrophilic Guide Wire | Boston Scientific Corp | 2003 | — |
| +3 | K040140 | IQ Guide Wire | Boston Scientific Corp | 2004 | 1 |
| +3 | K152231 | Hornet Guidewire, Hornet 10 Guidewire, Hornet 14 Guidewire | Boston Scientific Corporation | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1995 | 4 | 0 |
| 1996 | 3 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 1998 | 2 | 0 |
| 2003 | 2 | 0 |
| 2004 | 1 | 0 |
| 2005 | 1 | 0 |
| 2008 | 1 | 0 |
| 2011 | 1 | 0 |
| 2015 | 2 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQX device
- #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (9)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K943192 | Scimed Choice (TM) Ptca Guide WireSummary page 1…s: Submitter's Name and Address: Contact Person: Classification Name: Common or Usual Name: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems… | 1994 |
| * | K961015 | Scimed Choice/Ptca Guide Wire/Plus Ptca Guide Wire/Exchange Ptca Guide WireSummary page 1…ter's Name and Address: Contact Person: Classification Name: Common or Usual Name: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One… | 1996 |
| * | K945129 | Scimed Chioce Plus Ptca Guide WireSummary page 1…e and Address: Contact Person: Classification Name: Common or Usual Name: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One SCIMED P… | 1995 |
| * | K950113 | Scimed (R) Chice (TM) Exchange Ptca Guide WireSummary page 1…ntact Person: Classification Name: Common or Usual Name: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One SCIMED Place Maple Grove,… | 1995 |
| * | K941895 | Scimed 0.014 Ptca Guide Wire with Ice Hydrophilic CoatingSummary page 1…ssification Name: Common or Usual Name: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One SCIMED Place Maple Grove, Minnesota 55311 C… | 1994 |
| * | K960657 | Scimed Choice PT Exchange Extra Support Ptca and Long Taper Ptca Guide WireSummary page 1…n Name: Common or Usual Name: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One SCIMED Place Maple Grove, Minnesota 55311 Connie J. D… | 1996 |
| * | K950216 | Scimed Choice PT Plus (RM) Ptca Guide WireSummary page 1…Common or Usual Name: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One SCIMED Place Maple Grove, Minnesota 55311 Connie J. Del Toro… | 1995 |
| * | K950266 | Scimed (R) Choice (TM) PT Exchange Ptca Guide WireSummary page 1…ame: Proprietary Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One SCIMED Place Maple Grove, Minnesota 55311 Connie J. Del Toro (612) 494-2656 Ca… | 1995 |
| * | K960563 | Scimed Sceptor & Sceptor Exchange Ptca Guide WiresSummary page 1…Name: II. Name of Predicate Devices: 210(k) Reference No, K943192 & K961015 K945129 & K961015 K950113 & K961015 K941895 & K960657 K950216 & K960657 K950266 & K960657 K960563 SCIMED Life Systems, Inc. One SCIMED Place Maple Grove, Minnesota 55311 Connie J. Del Toro (612) 494-2656 Catheter Guide Wire… | 1996 |
What descends from it? (16)
See all 163 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Nov 19, 2002 | Not classified | Z-0592-03 | Other | Product is mislabled as a ChoICE Floppy Guide Wire when it is actually a ChoICE ES(Extra Support) Guide Wire. |
| Aug 22, 2002 | Not classified | Z-0591-03 | Other | Product labeled as Scimed ChoICE PT Extra Suport PTCA Guide Wire 300 cm were actually Scimed PT Graphix Intermediate PTCA Guide Wire 300 cm |
| Jul 16, 2002 | Not classified | Z-0589-03 | Other | Labeled as J tip but may be straight tip. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All DQX devicesDQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DQX
10in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQX
177in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQX
3in 2024
Class I (8 since 2007) Class II/III not classified
Adverse event reports per year · DQX
2,178in 2025
MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 85 | 12 | 760 |
| 2008 | 19 | 87 | 7 | 715 |
| 2009 | 18 | 87 | 49 | 687 |
| 2010 | 21 | 63 | 34 | 987 |
| 2011 | 18 | 43 | 3 | 1,311 |
| 2012 | 20 | 62 | 5 | 1,337 |
| 2013 | 18 | 119 | 7 (4) | 1,474 |
| 2014 | 18 | 103 | 0 | 1,323 |
| 2015 | 15 | 112 | 1 | 1,323 |
| 2016 | 14 | 179 | 2 (2) | 1,466 |
| 2017 | 19 | 85 | 17 | 1,524 |
| 2018 | 19 | 114 | 9 | 1,737 |
| 2019 | 13 | 173 | 2 | 1,679 |
| 2020 | 14 | 106 | 1 (1) | 1,536 |
| 2021 | 6 | 161 | 0 | 1,713 |
| 2022 | 15 | 212 | 0 | 1,647 |
| 2023 | 10 | 136 | 0 | 2,068 |
| 2024 | 11 | 134 | 3 | 2,210 |
| 2025 | 10 | 177 | 0 | 2,178 |
| 2026 | 12 | 145 | 4 (1) | — |
What is it indicated for?
The SCIMED CholCE PT Vision PTCA Guide Wires are intended to facilitate the placement and exchange of balloon dilatation catheters or other therapeutic devices during PTCA or other intravascular interventional procedures. The ChoICE PT Vision PTCA Guide Wires are not intended for use in the cerebral vasculature. The devices are provided sterile and intended for one procedure only.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K962572 · printed Nov 5, 2026
Cite this page
510(k) Report. “K962572: Scimed Choice PT Vision Ptca Guide Wire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K962572
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026