510(k) Report

510(k) · Cleared

Cleared

Infrasonics Adult Ventilator Trending Option

K964543510(k) TraditionalCleared Feb 14, 199793-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nellcor Puritan Bennett, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Feb 14, 1997 after a 93-day review. The FDA summary names its predicate without a number. 1 later device descends from it.

Decided
Feb 14, 1997
Review
93 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2004: 1 descendant cleared1995200020052010201520202025
  1. This deviceK964543 Infrasonics Adult Ventilator Trending OptionNellcor Puritan Bennett, Inc. · 1997
  2. Descendant · cites it directly · 0 of its ownK041412 Esprit Ventilator with Nico-Esprit Interface Option, Model V1000Respironics California, Inc. · 2004 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K041412Esprit Ventilator with Nico-Esprit Interface Option, Model V1000Respironics California, Inc. · 2004 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K964543Infrasonics Adult Ventilator Trending OptionNellcor Puritan Bennett, Inc.1997—
+1K041412Esprit Ventilator with Nico-Esprit Interface Option, Model V1000Respironics California, Inc.20046

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
FIG. 1 — Lineage of K964543, 1997–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CBK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Puritan Bennett Graphics 2.0 option for the Puritan-Bennett 7200 ventilator
Named without a submission number
—
*—Bird Products Corp. Graphic Monitor
Named without a submission number
—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K041412Esprit Ventilator with Nico-Esprit Interface Option, Model V1000Respironics California, Inc.20040

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K041412 (Respironics California, Inc., 2004) has gone furthest, with 0 descendants of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

This product is to be used only in conjunction with the Adult Star Model ventilator. It provides a monitoring function only and therefore has no direct interaction with ventilator function. The Trending option will periodically sample ventilator data to be used as trended parameters. This option is intended for the operator to track a total of 54 patient and ventilator parameters over a maximum time period of 72 hours. Three trended parameters can be…

Read the full statement (167 words)

This product is to be used only in conjunction with the Adult Star Model ventilator. It provides a monitoring function only and therefore has no direct interaction with ventilator function. The Trending option will periodically sample ventilator data to be used as trended parameters. This option is intended for the operator to track a total of 54 patient and ventilator parameters over a maximum time period of 72 hours. Three trended parameters can be displayed simultaneously. A cursor can then be used scan the trended dated to determine the time and magnitude of a particular occurrence or change in a monitored function. In addition, Patient data such as name, weight, clinician identification, and blood gas test data can be manually inputted. The Trending option allows real-time pressure, flow, and volume waveforms to be saved and recalled for comparison to subsequent waveforms. Pressure/Volume and Flow/Volume loops can also be saved and recalled for subsequent comparisons. A hardcopy print out can be made of all saved and trended data.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K964543: Infrasonics Adult Ventilator Trending Option.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K964543

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026