ClearedOximax NPB-40 Handheld Pulse Oximeter
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Nellcor Puritan Bennett, Inc. · DQA Oximeter
Cleared on Aug 11, 2005 as substantially equivalent to K963707 (Nellcor Puritan Bennett, Inc., 1996) and 1 other predicate after a 79-day review. Its family tree reaches back 6 generations to 1997. 28 later devices descend from it.
- Decided
- Aug 11, 2005
- Review
- 79 days
- Class
- Class II
- Product code
- DQA
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 6 generations to K962603 (1997). 12 ancestors in all, the oldest K904039 (1990). 28 later devices descend from it, 5 citing it directly.
- Root · 6 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
- 5 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
- 4 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
- 3 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
- 2 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
- 1 generation backK021090 Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc. · 2002
- This deviceK051352 Oximax NPB-40 Handheld Pulse OximeterNellcor Puritan Bennett, Inc. · 2005
- Descendant · cites it directly · 19 of its ownK072581 PM-60 Pulse OximeterShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008
- Descendant · 2 generations on · 9 of its ownK090599 MD300K1 Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd. · 2009
- Descendant · 3 generations on · 8 of its ownK152563 Pulse Oximeter (MD300M/MD300K2)Beijing Choice Electronic Technology Co., Ltd. · 2016
- Descendant · 4 generations on · 7 of its ownK162199 Cascade IOMAX Intraoperative MonitorCadwell Industries, Inc. · 2017 · Recalled
- Descendant · 5 generations on · 5 of its ownK212166 ISIS Headboxes, ISIS Neurostimulator, ISIS Xpert Plus, ISIS Xpert…Inomed Medizintechnik GmbH · 2022
Showing 5 of 28 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 28 · See all- K072581PM-60 Pulse OximeterShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008 · cites it directly19descendants
- K090599MD300K1 Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd. · 2009 · 2 generations on9descendants
- K152563Pulse Oximeter (MD300M/MD300K2)Beijing Choice Electronic Technology Co., Ltd. · 2016 · 3 generations on8descendants
- K162199Cascade IOMAX Intraoperative MonitorCadwell Industries, Inc. · 2017 · 4 generations on7descendants
- K212166ISIS Headboxes, ISIS Neurostimulator, ISIS Xpert Plus, ISIS Xpert, ISIS XpressInomed Medizintechnik GmbH · 2022 · 5 generations on5descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K962603 | Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables | Masimo Corp. | 1997 | — |
| −5 | K973887 | Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables | Masimo Corp. | 1998 | — |
| −4 | K982255 | Model 2000 Pulse Oximeter | Ivy Biomedical Systems, Inc. | 1998 | — |
| −3 | K991823 | N-395 Pulse Oximeter, Model N-395 | Nellcor Puritan Bennett, Inc. | 1999 | — |
| −2 | K012891 | Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and… | Nellcor Puritan Bennett, Inc. | 2002 | 1 |
| −1 | K021090 | Oximax N-550 Pulse Oximeter,Model N-550 Pulse Oximeter | Nellcor Puritan Bennett, Inc. | 2002 | — |
| 0 (this device) | K051352 | Oximax NPB-40 Handheld Pulse Oximeter | Nellcor Puritan Bennett, Inc. | 2005 | — |
| +1 | K072581 | PM-60 Pulse Oximeter | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2008 | — |
| +2 | K090599 | MD300K1 Pulse Oximeter | Beijing Choice Electronic Technololgy Co., Ltd. | 2009 | — |
| +3 | K152563 | Pulse Oximeter (MD300M/MD300K2) | Beijing Choice Electronic Technology Co., Ltd. | 2016 | — |
| +4 | K162199 | Cascade IOMAX Intraoperative Monitor | Cadwell Industries, Inc. | 2017 | 3 |
| +5 | K212166 | ISIS Headboxes, ISIS Neurostimulator, ISIS Xpert Plus, ISIS Xpert, ISIS Xpress | Inomed Medizintechnik GmbH | 2022 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1990 | 1 | 0 |
| 1993 | 1 | 0 |
| 1995 | 1 | 0 |
| 1996 | 2 | 0 |
| 1999 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 2 | 0 |
| 2009 | 4 | 0 |
| 2010 | 2 | 0 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 2 | 0 |
| 2015 | 1 | 0 |
| 2016 | 2 | 0 |
| 2017 | 2 | 0 |
| 2018 | 4 | 0 |
| 2020 | 1 | 0 |
| 2022 | 2 | 0 |
| 2023 | 3 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQA device
- #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K963707 | Nellcor Puritan Bennett NPB-40 Handheld Pulse (NPB-40)Summary page 1…21 CFR 870.2700 Substantially Equivalent Nelicor Puritan Bennett NPB-40 Handheld Pulse Devices: Oximeter, K963707. Neilcor Puritan Benrnett N-550 Pulse Oxirneter, K02 10… | 1996 |
| * | K021090 | Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterSummary page 1…Devices: Oximeter, K963707. Neilcor Puritan Benrnett N-550 Pulse Oxirneter, K02 1090 Device Description The OxiMax NPB-40 is a handheld, battery powered pulse oximeter used for mon… | 2002 |
What descends from it? (28)
See all 285 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 11 months on median.
- 3 of the 12 ancestors have a recall of any class.
- Of its descendants, K072581 (Shenzhen Mindray Bio-Medical Electronics Co., Ltd., 2008) has gone furthest, with 19 descendants of its own.
- 4 other devices also cite its predicate K963707.
How does its category compare?
All DQA devicesDQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DQA
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQA
182in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQA
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DQA
399in 2025
MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 122 | 6 | 325 |
| 2008 | 22 | 97 | 5 | 312 |
| 2009 | 35 | 117 | 29 | 281 |
| 2010 | 29 | 127 | 4 | 185 |
| 2011 | 15 | 195 | 1 | 164 |
| 2012 | 14 | 120 | 0 | 322 |
| 2013 | 15 | 182 | 0 | 468 |
| 2014 | 11 | 175 | 2 | 1,124 |
| 2015 | 13 | 158 | 1 | 2,082 |
| 2016 | 14 | 246 | 0 | 1,775 |
| 2017 | 9 | 200 | 0 | 1,190 |
| 2018 | 18 | 260 | 32 | 694 |
| 2019 | 19 | 158 | 0 | 548 |
| 2020 | 15 | 126 | 0 | 426 |
| 2021 | 10 | 174 | 0 | 553 |
| 2022 | 20 | 265 | 0 | 478 |
| 2023 | 13 | 317 | 0 | 392 |
| 2024 | 14 | 285 | 3 | 545 |
| 2025 | 15 | 182 | 0 | 399 |
| 2026 | 8 | 187 | 0 | — |
What is it indicated for?
The OxiMaxTM NPB-40 handheld pulse oximeter is indicated for continuous or spot check monitoring of functional arterial oxygen saturation (SpO2) and pulse rate of adult, pediatric and neonatal patients in hospital, hospital type facilities, transport and mobile environments as well as in the home care environment.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K051352 · printed Nov 5, 2026
Cite this page
510(k) Report. “K051352: Oximax NPB-40 Handheld Pulse Oximeter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K051352
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026