510(k) · Cleared
ClearedAvanta Orthopaedics Trapezium Implant
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Avanta Orthopaedics, Inc. · KYI Prosthesis, Wrist, Carpal Trapezium
Cleared on Jun 3, 1997 after a 159-day review. The FDA summary names its predicate without a number.
- Decided
- Jun 3, 1997
- Review
- 159 days
- Class
- Class II
- Product code
- KYI
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KYI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KYI device
- #1 K201072 Ensemble CMC, Size 141, Ensemble CMC, Size…score 1.9 · 6 generations · no Class I recall
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Dow Corning Corporation Silastic Swanson Trapezium Implant Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KYI devicesKYI Prosthesis, Wrist, Carpal Trapezium: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KYI
1in 2020
2026 to Oct 25, outlined.
Median 510(k) review, days · KYI
Too few KYI 510(k)s in any year since 2007 to give a median.
Recalls per year · KYI
1in 2016
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KYI
1in 2024
MAUDE reports naming product code KYI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 32 |
| 2008 | 0 | — | 0 | 51 |
| 2009 | 1 | — | 0 | 56 |
| 2010 | 0 | — | 2 | 25 |
| 2011 | 2 | — | 0 | 72 |
| 2012 | 0 | — | 0 | 22 |
| 2013 | 0 | — | 0 | 23 |
| 2014 | 0 | — | 0 | 4 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 1 | 3 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 1 | — | 0 | 4 |
| 2019 | 0 | — | 0 | 14 |
| 2020 | 1 | — | 0 | 8 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Avanta Orthopaedics Trapezium Implant may be considered for use in thumb disabilities because of osteoarthritis, post-traumatic arthritis, or rheumatoid arthritis as follows:
Localized pain and palpable crepitation during circumduction movements with axial compression of the thumb.
Loss of the thumb motion with decrease of normal pinch and grip strength.
Radiological evidence of arthritic changes of the trapeziometacarpal joint, trapeziotrapezoid and trapezium second metacarpal joint, singly or in combination.
Unstable, stiff, or painful distal joints of the thumb or swan-neck deformity.
Following an old Bennet fracture.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K965204 · printed Nov 6, 2026
Cite this page
510(k) Report. “K965204: Avanta Orthopaedics Trapezium Implant.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K965204
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026