510(k) · Cleared
ClearedRiwo Drive with Footswitch/Motor Handle, Coomplete,6000RPM/3000RPM/Rotary Blades and Abraders See Section 1:
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Richard Wolf Medical Instruments Corp. · HWE Instrument, Surgical, Orthopedic, Ac-Powered Motor And Accessory/Attachment
Cleared on Apr 7, 1997 as substantially equivalent to K871250 (Richard Wolf Medical Instruments Corp., 1987) after an 87-day review. Its family tree reaches back 1 generation to 1987. 11 later devices descend from it.
- Decided
- Apr 7, 1997
- Review
- 87 days
- Class
- Class I
- Product code
- HWE
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K871250 (1987). 11 later devices descend from it, 4 citing it directly.
- Root · 1 generation backK871250 Intra-Articulated Arthro Power SystemRichard Wolf Medical Instruments Corp. · 1987
- This deviceK970088 Riwo Drive with Footswitch/Motor Handle…Richard Wolf Medical Instruments Corp. · 1997
- Descendant · cites it directly · 9 of its ownK984521 Riwo Drive System 2302 with Generator, Small Motor Handles…Richard Wolf Medical Instruments Corp. · 1999
- Descendant · cites it directly · 8 of its ownK030082 Power Control 2303 with Power Stick M4, Model# 2303.011/.901/.911…Richard Wolf Medical Instruments Corp. · 2003
- Descendant · 2 generations on · 6 of its ownK041610 Morce Scope Set 8970 with Power Control 2303 and Suction Pump 2207Richard Wolf Medical Instruments Corp. · 2004
- Descendant · 3 generations on · 2 of its ownK192499 Cyber BladeSIDAM S.r.l. · 2020
- Descendant · 3 generations on · 1 of its ownK213597 MultiCut SoloAsclepion Laser Technologies GmbH · 2023
Showing 5 of 11 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 11 · See all- K984521Riwo Drive System 2302 with Generator, Small Motor Handles, 8563.111, 8563.351Richard Wolf Medical Instruments Corp. · 1999 · cites it directly9descendants
- K030082Power Control 2303 with Power Stick M4, Model# 2303.011/.901/.911, 8564.121/.851Richard Wolf Medical Instruments Corp. · 2003 · cites it directly8descendants
- K041610Morce Scope Set 8970 with Power Control 2303 and Suction Pump 2207Richard Wolf Medical Instruments Corp. · 2004 · 2 generations on6descendants
- K192499Cyber BladeSIDAM S.r.l. · 2020 · 3 generations on2descendants
- K213597MultiCut SoloAsclepion Laser Technologies GmbH · 2023 · 3 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K871250 | Intra-Articulated Arthro Power System | Richard Wolf Medical Instruments Corp. | 1987 | — |
| 0 (this device) | K970088 | Riwo Drive with Footswitch/Motor Handle, Coomplete,6000RPM/3000RPM/Rotary… | Richard Wolf Medical Instruments Corp. | 1997 | — |
| +1 | K984521 | Riwo Drive System 2302 with Generator, Small Motor Handles, 8563.111, 8563.351 | Richard Wolf Medical Instruments Corp. | 1999 | — |
| +1 | K030082 | Power Control 2303 with Power Stick M4, Model# 2303.011/.901/.911, 8564.121/.851 | Richard Wolf Medical Instruments Corp. | 2003 | — |
| +2 | K041610 | Morce Scope Set 8970 with Power Control 2303 and Suction Pump 2207 | Richard Wolf Medical Instruments Corp. | 2004 | — |
| +3 | K192499 | Cyber Blade | SIDAM S.r.l. | 2020 | — |
| +3 | K213597 | MultiCut Solo | Asclepion Laser Technologies GmbH | 2023 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 2 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2008 | 1 | 0 |
| 2011 | 1 | 0 |
| 2020 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 1 | 0 |
| 2026 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HWE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K871250 | Intra-Articulated Arthro Power SystemSummary page 1…n name: Drive Generator Instrument, surgical, orthopedic, DC-powerded o motor and accessory/attachment 510(k) Trade or proprietary or model nanu Manufacturer Number 1 K871250 1 intra-articulated arthro power system 2161 1 Richard Wolf M.I.C. 2 2 Surgical Drive System EP-1 2 Dyonics 3 3 Shaver System S… | 1987 |
| * | — | Surgical Drive System EP-1 Named without a submission number | |
| * | — | Shaver System SE Named without a submission number | |
| * | — | Drive System Apex Named without a submission number |
What descends from it? (11)
See all 114 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K984521 | Riwo Drive System 2302 with Generator, Small Motor Handles, 8563.111, 8563.351 | 1999 | 9 |
| K030082 | Power Control 2303 with Power Stick M4, Model# 2303.011/.901/.911, 8564.121/.851 | 2003 | 8 |
| K984304 | Riwo Drive Generator | 1999 | 1 |
| K080617 | Power Drive ART1 2304 with Motor Handles, Tools and Accessories | 2008 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All HWE devicesHWE Instrument, Surgical, Orthopedic, Ac-Powered Motor And Accessory/Attachment: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HWE
1in 2015
2026 to Oct 25, outlined.
Median 510(k) review, days · HWE
Too few HWE 510(k)s in any year since 2007 to give a median.
Recalls per year · HWE
1in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HWE
2,848in 2025
MAUDE reports naming product code HWE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 123 |
| 2008 | 0 | — | 0 | 72 |
| 2009 | 0 | — | 4 | 180 |
| 2010 | 0 | — | 2 | 297 |
| 2011 | 1 | — | 2 | 138 |
| 2012 | 0 | — | 0 | 221 |
| 2013 | 0 | — | 1 | 1,243 |
| 2014 | 0 | — | 3 | 3,794 |
| 2015 | 1 | — | 5 | 5,567 |
| 2016 | 0 | — | 2 | 4,974 |
| 2017 | 0 | — | 1 | 5,074 |
| 2018 | 0 | — | 0 | 3,589 |
| 2019 | 0 | — | 0 | 3,452 |
| 2020 | 0 | — | 0 | 3,248 |
| 2021 | 0 | — | 0 | 3,140 |
| 2022 | 0 | — | 0 | 3,327 |
| 2023 | 0 | — | 0 | 3,397 |
| 2024 | 0 | — | 0 | 3,686 |
| 2025 | 0 | — | 0 | 2,848 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Riwo Drive System is used for arthroscopic procedures in human joints.
It is also used for sinus procedures in the nasal cavity.
The Riwo Drive generator with motor handle serves to drive WOLF blades or abraders.
Depending on the indication, different styles of blades are attached to the motor handle. Two basic styles are most common:
1. Blades are for removal of soft tissue and cartilage
2. Abraders for bones and bony structures
The use of the system is reserved to surgeons with special training in the respective procedures.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K970088 · printed Nov 4, 2026
Cite this page
510(k) Report. “K970088: Riwo Drive with Footswitch/Motor Handle, Coomplete,6000RPM/3000RPM/Rotary Blades and Abraders See Section 1:.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K970088
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026