Doctors Review System

K970402510(k) TraditionalCleared Mar 26, 199751-day reviewClass II21 CFR 892.2050Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Digisonics, Inc. · LLZ System, Image Processing, Radiological

Cleared on Mar 26, 1997 after a 51-day review. The FDA summary names its predicate without a number. 3 later devices descend from it. It has been recalled 5 times.

Decided
Mar 26, 1997
Review
51 days
Class
Class II
Product code
LLZ
Recalls
5
Predicates
0

3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared2005: 1 descendant cleared2026: 1 descendant cleared1995200020052010201520202025
  1. This deviceK970402 Doctors Review SystemDigisonics, Inc. · 1997
  2. Descendant · cites it directly · 2 of its ownK022877 Observer Ultrasound Reporting and Imaging SystemVision Chips, Inc. · 2003
  3. Descendant · cites it directly · 1 of its ownK051639 AS-Obgyn Information System; as-Emr SystemAs Software, Inc. · 2005 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK260205 AS Software Version AseraAS Software, LLC · 2026

Most influential descendants

Showing 3 of 3 · See all
  • K022877Observer Ultrasound Reporting and Imaging SystemVision Chips, Inc. · 2003 · cites it directly2descendants
  • K051639AS-Obgyn Information System; as-Emr SystemAs Software, Inc. · 2005 · cites it directly1descendant
  • K260205AS Software Version AseraAS Software, LLC · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K970402Doctors Review SystemDigisonics, Inc.1997—
+1K022877Observer Ultrasound Reporting and Imaging SystemVision Chips, Inc.2003—
+1K051639AS-Obgyn Information System; as-Emr SystemAs Software, Inc.20051
+2K260205AS Software Version AseraAS Software, LLC2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
200510
202610
FIG. 1 — Lineage of K970402, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—ATL Nova Microsonics - Image Vue DCR System
Named without a submission number
—
*—TomTec - TomTec 90 with Echocardiography Offline Review
Named without a submission number
—
*—General Electric - RT 4000 Data Management Center
Named without a submission number
—
*—On-Time Medical - Click*View
Named without a submission number
—

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K022877Observer Ultrasound Reporting and Imaging SystemVision Chips, Inc.20032
K051639AS-Obgyn Information System; as-Emr SystemAs Software, Inc.20051

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 26, 2023Class IIZ-2214-2023Labeling designSoftware issue
Feb 6, 2009Not classifiedZ-2193-2011OtherLeft ventricle volume was inaccurate when the volumes were measured from images having different scales.
Jan 20, 2009Not classifiedZ-2180-2011Device DesignData from one patient's study had the potential for being put into another patient's report.
Nov 4, 2008Not classifiedZ-2166-2011Device DesignFailure of software to update some measurements when tracings or points are amended after measurement calculations have been performed.
Feb 9, 2007Not classifiedZ-2113-2011OtherStudy would on occasion have fetal heart rate and/or cervical length on the report that was not entered nor did it belong to that patient. Software displayed incorrect data for fetal heart rate and cervical length in OB ultrasound reports.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K022877 (Vision Chips, Inc., 2003) has gone furthest, with 2 descendants of its own.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

The Doctors Review System (DRS) is general purpose, standalone software for creating patient reports. It consists of Digisonics word processing software together with off-the-shelf computer equipment (PC, VCR, printer, etc.). Using the system, the physician reviews data (from other sources), notes clinical observations from sets of menus, and creates patient reports. Optional analysis programs are provided for quantitation of echo and cath lab data. No diagnoses are made by the software. It is not used for therapy or patient monitoring.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K970402: Doctors Review System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K970402

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026