GLORY

K970680510(k) TraditionalCleared Jun 20, 1997116-day reviewClass II21 CFR 892.1710

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Elscint, Inc. · IZH System, X-Ray, Mammographic

Cleared on Jun 20, 1997 as substantially equivalent to K960381 (Elscint, Inc., 1996) after a 116-day review. Its family tree reaches back 2 generations to 1995. 1 later device descends from it.

Decided
Jun 20, 1997
Review
116 days
Class
Class II
Product code
IZH
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K941353 (1995). 1 later device descends from it, 1 citing it directly.

  1. Root · 2 generations backK941353 Mam-CH22S Mammography System with Optional Mammoguide Steriotactic…Elscint, Inc. · 1995
  2. 1 generation backK960381 Mam-CH22S with Automatic Filter Selection OptionElscint, Inc. · 1996
  3. This deviceK970680 GLORYElscint, Inc. · 1997
  4. Descendant · cites it directly · 0 of its ownK983313 Advanced Automatic Detector Selection Option for GloryElscint, Inc. · 1998

Most influential descendants

Showing 1 of 1 · See all
  • K983313Advanced Automatic Detector Selection Option for GloryElscint, Inc. · 1998 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K941353Mam-CH22S Mammography System with Optional Mammoguide Steriotactic Biopsy SystemElscint, Inc.1995—
−1K960381Mam-CH22S with Automatic Filter Selection OptionElscint, Inc.1996—
0 (this device)K970680GLORYElscint, Inc.1997—
+1K983313Advanced Automatic Detector Selection Option for GloryElscint, Inc.1998—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199810
FIG. 1 — Lineage of K970680, 1995–1998Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IZH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IZH device

  1. #1 K202294 Affirm Contrast Biopsyscore 1.0 · 4 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K960381Mam-CH22S with Automatic Filter Selection Option
Summary page 1
…FETY AND EFFECTIVENESS The 510(k) premarket notification for the GLORY mammography system describes a modification of the legally marketed MAM-CH22S mammography system (K960381). The intended use and the indications of use of the GLORY mammography system are identical to those of the MAM-CH22S mammograph…
Elscint, Inc.1996—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K983313Advanced Automatic Detector Selection Option for GloryElscint, Inc.19980

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 2 years and passes through 1 company; a new generation was cleared every 1.1 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K983313 (Elscint, Inc., 1998) has gone furthest, with 0 descendants of its own.

How does its category compare?

All IZH devices

IZH System, X-Ray, Mammographic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IZH

1in 2021

2007: 32008: 12010: 22011: 12012: 22013: 22015: 12016: 32019: 12020: 12021: 1
2007high 3 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IZH

64in 2016

2007: 30 days median2016: 64 days median
2007high 64 (2016) · low 30 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IZH

2in 2008

2008: 2
2007high 2 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IZH

15in 2025

2007: 112008: 52009: 142010: 72011: 52012: 182013: 92014: 72015: 82016: 92017: 122018: 252019: 392020: 72021: 92022: 42023: 82024: 52025: 15
2007high 39 (2019) · low 4 (2022)2025

MAUDE reports naming product code IZH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007330011
20081—25
20090—014
20102—07
20111—05
20122—018
20132—09
20140—07
20151—08
201636409
20170—012
20180—025
20191—039
20201—07
20211—09
20220—04
20230—08
20240—05
20250—015
20260—0—

What is it indicated for?

Radiography of the breast

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K970680: GLORY.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K970680

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026