510(k) · Cleared
ClearedVolumax CT Imaging System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Elscint, Inc. · JAK System, X-Ray, Tomography, Computed
Cleared on Sep 2, 1998 as substantially equivalent to K945512 (Elscint, Inc., 1995) and 3 other predicates after an 83-day review. Its family tree reaches back 2 generations to 1993. 264 later devices descend from it.
- Decided
- Sep 2, 1998
- Review
- 83 days
- Class
- Class II
- Product code
- JAK
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 2 generations to K930090 (1993). 6 ancestors in all. 264 later devices descend from it, 1 citing it directly.
- Root · 2 generations backK930090 HelicatElscint, Inc. · 1993
- 1 generation backK961464 Select/SPElscint, Inc. · 1996 · Recalled
- This deviceK982060 Volumax CT Imaging SystemElscint, Inc. · 1998
- Descendant · cites it directly · 263 of its ownK012009 MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · Recalled
- Descendant · 2 generations on · 214 of its ownK033326 Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc. · 2003 · Recalled
- Descendant · 2 generations on · 147 of its ownK042293 Brilliance CT, Private Practice CV Configuration, CT ScannerPhilips Medical Systems (Cleveland), Inc. · 2004 · Recalled
- Descendant · 3 generations on · 92 of its ownK130159 Qlab Quantification Software Heart ModelPhilips Health Care · 2013
- Descendant · 4 generations on · 91 of its ownK132165 Qlab Quantification SoftwarePhilips Ultrasound, Inc. · 2013 · Recalled
Showing 5 of 264 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 264 · See all- K012009MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · cites it directly263descendants
- K033326Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc. · 2003 · 2 generations on214descendants
- K042293Brilliance CT, Private Practice CV Configuration, CT ScannerPhilips Medical Systems (Cleveland), Inc. · 2004 · 2 generations on147descendants
- K130159Qlab Quantification Software Heart ModelPhilips Health Care · 2013 · 3 generations on92descendants
- K132165Qlab Quantification SoftwarePhilips Ultrasound, Inc. · 2013 · 4 generations on91descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K930090 | Helicat | Elscint, Inc. | 1993 | — |
| −1 | K961464 | Select/SP | Elscint, Inc. | 1996 | 3 |
| 0 (this device) | K982060 | Volumax CT Imaging System | Elscint, Inc. | 1998 | — |
| +1 | K012009 | MX8000 Idt CT System | Marconi Medical Systems, Inc. | 2001 | 61 |
| +2 | K033326 | Philips Plus Computed Tomography System | Philips Medical Systems, Inc. | 2003 | 131 |
| +2 | K042293 | Brilliance CT, Private Practice CV Configuration, CT Scanner | Philips Medical Systems (Cleveland), Inc. | 2004 | 1 |
| +3 | K130159 | Qlab Quantification Software Heart Model | Philips Health Care | 2013 | — |
| +4 | K132165 | Qlab Quantification Software | Philips Ultrasound, Inc. | 2013 | 1 |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 2 | 0 |
| 1995 | 1 | 0 |
| 1997 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 1 | 0 |
| 2003 | 3 | 0 |
| 2004 | 7 | 0 |
| 2005 | 3 | 0 |
| 2006 | 3 | 0 |
| 2007 | 3 | 0 |
| 2008 | 7 | 0 |
| 2009 | 4 | 0 |
| 2010 | 2 | 0 |
| 2011 | 4 | 0 |
| 2012 | 6 | 0 |
| 2013 | 6 | 0 |
| 2014 | 9 | 0 |
| 2015 | 3 | 0 |
| 2016 | 5 | 0 |
| 2017 | 12 | 0 |
| 2018 | 14 | 0 |
| 2019 | 9 | 0 |
| 2020 | 22 | 0 |
| 2021 | 19 | 0 |
| 2022 | 22 | 0 |
| 2023 | 20 | 0 |
| 2024 | 19 | 0 |
| 2025 | 35 | 0 |
| 2026 | 26 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K945512 | HRSW Option for CT Twin FlashSummary page 1…g. e Minimum scan time of 0.3 second. e Minimum reconstruction time of 0.5 second. 4. Predicate Devices ¢ CT-Twin flash submitted in “HRSW Option for CT-Twin Flash” K945512. ¢ SeleCT/SP, K961464 ¢ OmniPro which is a trade name of ProVision, K954678 Related devices: - XRT-7 Option for CT scanner, K… | 1995 |
| * | K961464 | Select/SPSummary page 1…e of 0.3 second. e Minimum reconstruction time of 0.5 second. 4. Predicate Devices ¢ CT-Twin flash submitted in “HRSW Option for CT-Twin Flash” K945512. ¢ SeleCT/SP, K961464 ¢ OmniPro which is a trade name of ProVision, K954678 Related devices: - XRT-7 Option for CT scanner, K964583 _ Siemens Somato… | 1996 |
| * | K941546 | Somatom Project 059Summary page 1…K945512. ¢ SeleCT/SP, K961464 ¢ OmniPro which is a trade name of ProVision, K954678 Related devices: - XRT-7 Option for CT scanner, K964583 _ Siemens Somatom Plus 4, K941546, K964747 - Siemens Magnetom Project O16, K932271 510(k) Summary 5. Safety and Effectiveness Considerations The… | 1994 |
| * | K964747 | Somatom Plus 4 CT ScannerSummary page 1…¢ SeleCT/SP, K961464 ¢ OmniPro which is a trade name of ProVision, K954678 Related devices: - XRT-7 Option for CT scanner, K964583 _ Siemens Somatom Plus 4, K941546, K964747 - Siemens Magnetom Project O16, K932271 510(k) Summary 5. Safety and Effectiveness Considerations The safety o… | 1997 |
What descends from it? (264)
See all 2641 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K012009 | MX8000 Idt CT System | 2001 | 263 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 5 years and passes through 1 company; a new generation was cleared every 3.3 years on median.
- 1 of the 6 ancestors has a recall of any class.
- Of its descendants, K012009 (Marconi Medical Systems, Inc., 2001) has gone furthest, with 263 descendants of its own.
- 3 other devices also cite its predicate K945512.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
Whole body computerized tomography.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982060 · printed Nov 4, 2026
Cite this page
510(k) Report. “K982060: Volumax CT Imaging System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K982060
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026