510(k) · Cleared
ClearedVarious Arthroscopes, Endoscopic Blades, Manual Instruments
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Smith & Nephew, Inc. · HRX Arthroscope
Cleared on Jun 13, 1997 as substantially equivalent to K771218 (Dyonics, Inc., 1978) and 11 other predicates after a 71-day review. Its family tree reaches back 2 generations to 1983. 60 later devices descend from it.
- Decided
- Jun 13, 1997
- Review
- 71 days
- Class
- Class II
- Product code
- HRX
- Recalls
- None
- Predicates
- 13
Its longest line of descent runs back 2 generations to K833587 (1983). 12 ancestors in all, the oldest K771218 (1978). 60 later devices descend from it, 5 citing it directly.
- Root · 2 generations backK833587 Disposable Arthroscopy BladeDyonics, Inc. · 1983
- 1 generation backK900070 Modified Uses of the Arthroscopic Surgical SystemDyonics, Inc. · 1990
- This deviceK971253 Various Arthroscopes, Endoscopic Blades, Manual InstrumentsSmith & Nephew, Inc. · 1997
- Descendant · cites it directly · 32 of its ownK043395 Smith & Nephew VideoarthroscopeSmith & Nephew, Inc. · 2005
- Descendant · 2 generations on · 30 of its ownK072879 Innervue Diagnostic Scope SystemBiomet Orthopedics, Inc. · 2008 · Recalled
- Descendant · 2 generations on · 21 of its ownK082293 Surgview Integrated Visualization SystemBiovision Technologies, LLC · 2008
- Descendant · cites it directly · 21 of its ownK080560 Henke Sass Wolf of America ArthroscopeHenke Sass Wolf of America, Inc. · 2008
- Descendant · 2 generations on · 16 of its ownK093717 C-Mor Visualization DeviceAxis Surgical Technologies, Inc. · 2010
Showing 5 of 60 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 60 · See all- K043395Smith & Nephew VideoarthroscopeSmith & Nephew, Inc. · 2005 · cites it directly32descendants
- K072879Innervue Diagnostic Scope SystemBiomet Orthopedics, Inc. · 2008 · 2 generations on30descendants
- K082293Surgview Integrated Visualization SystemBiovision Technologies, LLC · 2008 · 2 generations on21descendants
- K080560Henke Sass Wolf of America ArthroscopeHenke Sass Wolf of America, Inc. · 2008 · cites it directly21descendants
- K093717C-Mor Visualization DeviceAxis Surgical Technologies, Inc. · 2010 · 2 generations on16descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K833587 | Disposable Arthroscopy Blade | Dyonics, Inc. | 1983 | — |
| −1 | K900070 | Modified Uses of the Arthroscopic Surgical System | Dyonics, Inc. | 1990 | — |
| 0 (this device) | K971253 | Various Arthroscopes, Endoscopic Blades, Manual Instruments | Smith & Nephew, Inc. | 1997 | — |
| +1 | K043395 | Smith & Nephew Videoarthroscope | Smith & Nephew, Inc. | 2005 | — |
| +2 | K072879 | Innervue Diagnostic Scope System | Biomet Orthopedics, Inc. | 2008 | 2 |
| +2 | K082293 | Surgview Integrated Visualization System | Biovision Technologies, LLC | 2008 | — |
| +1 | K080560 | Henke Sass Wolf of America Arthroscope | Henke Sass Wolf of America, Inc. | 2008 | — |
| +2 | K093717 | C-Mor Visualization Device | Axis Surgical Technologies, Inc. | 2010 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1982 | 1 | 0 |
| 1988 | 1 | 0 |
| 1990 | 1 | 0 |
| 1991 | 1 | 0 |
| 1992 | 1 | 0 |
| 1994 | 1 | 0 |
| 1995 | 2 | 0 |
| 1996 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 1 | 0 |
| 2001 | 4 | 0 |
| 2005 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 3 | 0 |
| 2010 | 3 | 0 |
| 2011 | 3 | 0 |
| 2012 | 3 | 0 |
| 2013 | 1 | 0 |
| 2014 | 5 | 0 |
| 2015 | 4 | 0 |
| 2016 | 4 | 0 |
| 2017 | 1 | 0 |
| 2018 | 3 | 0 |
| 2019 | 4 | 0 |
| 2020 | 3 | 0 |
| 2021 | 4 | 0 |
| 2022 | 3 | 0 |
| 2023 | 1 | 0 |
| 2024 | 3 | 0 |
| 2025 | 2 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRX device
- #1 K260203 Fule Vertebroplasty Balloon Catheterscore 14.9 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (13)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K771218 | Intra-Articular ShaverSummary page 1…ices in this 510(k) submission were originally reviewed and determined to be substantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Sum… | 1978 |
| * | K820367 | Intra-Articular Surgical SystemSummary page 1…is 510(k) submission were originally reviewed and determined to be substantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of De… | 1982 |
| * | K880150 | Pacesetter (TM) 3500 Arthroscopic Surgical SystemSummary page 1…submission were originally reviewed and determined to be substantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Funct… | 1988 |
| * | K914559 | Small Joint SystemSummary page 1…were originally reviewed and determined to be substantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The… | 1992 |
| * | K961228 | Karl Storz Magnifying ArthrosocpesSummary page 1…inally reviewed and determined to be substantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The Smith & N… | 1996 |
| * | K954989 | Dyonics Disposable Endoscopic Surgery BladesSummary page 1…iewed and determined to be substantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The Smith & Nephew, Inc… | 1995 |
| * | K904284 | Arthroscopic Surgical BladeSummary page 1…scopic Surgery Blades are similar to product currently marketed under 510(k) #K900070. Manual Instruments are longer versions of product currently marketed under 510(k) #K904284 or those that are Class |, exempt devices. Predicate Device : The devices in this 510(k) submission were originally reviewed an… | 1990 |
| * | K953695 | Dyonics Disposable Arthroscopic BladesSummary page 1…to be substantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The Smith & Nephew, Inc., Endoscopy Divisio… | 1995 |
| Kept off the family tree | K941038 | Unnamed device Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree Summary page 1…stantially equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The Smith & Nephew, Inc., Endoscopy Division Arthrosc… | |
| * | K934299 | Dyonics Disposable Arthroscopic Surgery Blades ModificationSummary page 1…equivalent to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The Smith & Nephew, Inc., Endoscopy Division Arthroscopes and A… | 1994 |
| * | K912453 | Intelijet TM Fluid Management SystemSummary page 1…t to a predicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The Smith & Nephew, Inc., Endoscopy Division Arthroscopes and Accessories… | 1991 |
| * | K833587 | Disposable Arthroscopy BladeSummary page 1…dicate device under one or more of the following 510(k)s : #K771218, #K820367, #K880150, #K914559, #K961228, #K954989, #K904284, #K953695, #K941038, #K934299, #K912453, #K833587, and #K900070. Summary of Device Function : The Smith & Nephew, Inc., Endoscopy Division Arthroscopes and Accessories are to be… | 1983 |
| * | K900070 | Modified Uses of the Arthroscopic Surgical SystemSummary page 1…iate for use within the hip joint as well as all other previously approved indications. Endoscopic Surgery Blades are similar to product currently marketed under 510(k) #K900070. Manual Instruments are longer versions of product currently marketed under 510(k) #K904284 or those that are Class |, exempt dev… | 1990 |
What descends from it? (60)
See all 605 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 7.3 years on median.
- None of the 12 ancestors has a recall.
- Of its descendants, K043395 (Smith & Nephew, Inc., 2005) has gone furthest, with 32 descendants of its own.
- 6 other devices also cite its predicate K771218.
How does its category compare?
All HRX devicesHRX Arthroscope: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HRX
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRX
107in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRX
1in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRX
2,076in 2025
MAUDE reports naming product code HRX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 89 | 3 | 421 |
| 2008 | 9 | 115 | 13 | 441 |
| 2009 | 11 | 139 | 23 | 558 |
| 2010 | 9 | 114 | 12 | 612 |
| 2011 | 3 | 84 | 6 | 631 |
| 2012 | 11 | 102 | 0 | 778 |
| 2013 | 12 | 90 | 4 | 678 |
| 2014 | 9 | 140 | 0 | 802 |
| 2015 | 4 | 132 | 7 | 763 |
| 2016 | 8 | 89 | 0 | 469 |
| 2017 | 4 | 97 | 0 | 934 |
| 2018 | 12 | 101 | 1 | 1,581 |
| 2019 | 12 | 45 | 0 | 1,676 |
| 2020 | 7 | 141 | 0 | 1,706 |
| 2021 | 7 | 57 | 3 | 1,908 |
| 2022 | 3 | 89 | 0 | 1,406 |
| 2023 | 4 | 249 | 0 | 1,852 |
| 2024 | 6 | 110 | 1 | 2,427 |
| 2025 | 9 | 107 | 0 | 2,076 |
| 2026 | 7 | 217 | 0 | — |
What is it indicated for?
The Smith & Nephew, Inc., Endoscopy Division Arthroscopes and Accessories are indicated for use in diagnostic and operative arthroscopic procedures to provide illumination and visualization of the shoulder, knee, elbow, ankle, wrist and jaw, also to provide illumination and visualization during arthroscopic diagnostic procedures and removal of loose bodies and soft tissue within the hip joint as size/length appropriate. The Smith & Nephew, Inc.…
Read the full statement (117 words)
The Smith & Nephew, Inc., Endoscopy Division Arthroscopes and Accessories are indicated for use in diagnostic and operative arthroscopic procedures to provide illumination and visualization of the shoulder, knee, elbow, ankle, wrist and jaw, also to provide illumination and visualization during arthroscopic diagnostic procedures and removal of loose bodies and soft tissue within the hip joint as size/length appropriate.
The Smith & Nephew, Inc., Endoscopy Division sterile, disposable Endoscopic Surgery Blades as indicated for use during arthroscopic resection of soft and osseous tissue in various large and small articular cavities including the hip joint. Blades which are size-appropriate are indicated for use in the following joints : shoulder, knee, elbow, ankle, wrist, jaw and the hip joint.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K971253 · printed Nov 6, 2026
Cite this page
510(k) Report. “K971253: Various Arthroscopes, Endoscopic Blades, Manual Instruments.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K971253
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026