510(k) Report

510(k) · Cleared

Cleared

Maglife C

K972535510(k) TraditionalCleared Jan 13, 1998189-day reviewClass II21 CFR 870.1025

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Odam · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)

Cleared on Jan 13, 1998 as substantially equivalent to K950264 (Odam, 1996) and 2 other predicates after a 189-day review. Its family tree reaches back 2 generations to 1987.

Decided
Jan 13, 1998
Review
189 days
Class
Class II
Product code
MHX
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K864889 (1987). 4 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1997: 1 other ancestor1995: 1 other ancestorK864889 · Omni-Trak · Invivo Research Labs, Inc. · 1987K950264 · Maglife · Odam · 19961985199019952000
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor K950264 · Maglife · Odam · 1996K864889 · Omni-Trak · Invivo Research Labs, Inc. · 19870
  1. Root · 2 generations backK864889 Omni-TrakInvivo Research Labs, Inc. · 1987
  2. 1 generation backK950264 MaglifeOdam · 1996
  3. This deviceK972535 Maglife COdam · 1998
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K864889Omni-TrakInvivo Research Labs, Inc.1987—
−1K950264MaglifeOdam1996—
0 (this device)K972535Maglife COdam1998—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199710
FIG. 1 — Lineage of K972535, 1987–1998Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MHX device

  1. #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K950264Maglife
Summary page 2
…tion Names: patient physiological monitor 5. Predicate Devices The legally marketed devices to which equivalence is being claimed are; . MAGLIFE, marketed by O.D.A.M. (K950264) Additional Information For K972535 October 13, 1997 Page B-1 . MRI-Compatible Model 9500 manufactured by Magnet…
Odam1996—
*K954120Model 9500 MR-Compatible Multigas Monitor
Summary page 3
…by O.D.A.M. (K950264) Additional Information For K972535 October 13, 1997 Page B-1 . MRI-Compatible Model 9500 manufactured by Magnetic Resonance Corp. (K954120) . Omni Trak 3100 MRI manufactured by In Vivo Research (K864889) 6. Device Description MAGLIFE C is a multi-parameter patient m…
Magnetic Resonance Equipment Corp.1997—
*K864889Omni-Trak
Summary page 3
…13, 1997 Page B-1 . MRI-Compatible Model 9500 manufactured by Magnetic Resonance Corp. (K954120) . Omni Trak 3100 MRI manufactured by In Vivo Research (K864889) 6. Device Description MAGLIFE C is a multi-parameter patient monitor which has been designed for use in the immediate vicinity…
Invivo Research Labs, Inc.1987—

Also cleared against K950264: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 9.6 years on median.
  • None of the 4 ancestors has a recall.
  • 1 other device also cites its predicate K950264.

How does its category compare?

All MHX devices

MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MHX

8in 2025

2007: 152008: 162009: 132010: 202011: 122012: 162013: 212014: 132015: 142016: 132017: 142018: 112019: 72020: 112021: 52022: 152023: 82024: 52025: 82026 (partial year): 14
2007high 21 (2013) · low 5 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MHX

192in 2025

2007: 96 days median2008: 58 days median2009: 57 days median2010: 90 days median2011: 81 days median2012: 88 days median2013: 120 days median2014: 248 days median2015: 203 days median2016: 149 days median2017: 134 days median2018: 203 days median2019: 243 days median2020: 196 days median2021: 195 days median2022: 189 days median2023: 229 days median2024: 181 days median2025: 192 days median2026 (partial year): 205 days median
2007high 248 (2014) · low 57 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MHX

21so far in 2026, the most since 2007

2007: 32008: 22009: 72010: 132011: 162012: 112013: 142014: 62015: 52016: 72017: 62018: 122019: 62022: 62023: 32024: 32025: 152026 (partial year): 21
2007high 21 (2026) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MHX

3,761in 2025

2007: 1312008: 2322009: 3822010: 9552011: 9492012: 6762013: 1,9972014: 1,6092015: 1,2842016: 1,1052017: 1,1152018: 2,1572019: 1,4622020: 1,7142021: 2,4232022: 1,4702023: 2,2542024: 2,8142025: 3,761
2007high 3,761 (2025) · low 131 (2007)2025

MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715963131
200816582232
200913577382
2010209013955
2011128116949
2012168811676
201321120141,997
20141324861,609
20151420351,284
20161314971,105
20171413461,115
201811203122,157
2019724361,462
20201119601,714
2021519502,423
20221518961,470
2023822932,254
2024518132,814
20258192153,761
20261420521—

What is it indicated for?

The Maglife C is a multi-parameter patient monitor which is indicated for monitoring electrocardiogram (ECG), pulse oximetry (SpO,), pulse rate, partial carbon dioxide pressure at the end of expiration (EtCO,), nitrous oxide concentration (%N D), partial pressure of inspired carbon dioxide (min inspired CO,), respiratory rate (RR), noninvasive blood pressure (NIBP), invasive blood pressure (IBP), concentration of gas inspired and expired (isoflurane, halothane, enflurane, desflurane, sevoflurane), and fraction of inspired oxygen (FiO,) in the immediate vicinity of a Magnetic Resonance Imagers for the surveillance of patients undergoing MRI examinations.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K972535: Maglife C.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K972535

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026