510(k) · Cleared
ClearedModified Olbert Balloon Catheter System, Noprofile Olbert Balloon Catheter System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Boston Scientific Corp · FGE Stents, Drains And Dilators For The Biliary Ducts
Cleared on Nov 10, 1997 as substantially equivalent to K934411 (Meadox Medicals, Div. Boston Scientific Corp., 1994) and 4 other predicates after an 82-day review. Its family tree reaches back 1 generation to 1985. 1 later device descends from it.
- Decided
- Nov 10, 1997
- Review
- 82 days
- Class
- Class II
- Product code
- FGE
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 1 generation to K851647 (1985). 5 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 1 generation backK851647 Olbert Catheter System for Biliary Tract DilatatioMeadox Surgimed, Inc. · 1985
- This deviceK973113 Modified Olbert Balloon Catheter System, Noprofile Olbert Balloon…Boston Scientific Corp · 1997
- Descendant · cites it directly · 0 of its ownK010714 Expander, Models 1400880, 1401280, 1401680, 1401880, 1410420…Medi-Globe Corp. · 2003
Most influential descendants
Showing 1 of 1 · See all- K010714Expander, Models 1400880, 1401280, 1401680, 1401880, 1410420, 1410620, 1410830Medi-Globe Corp. · 2003 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K851647 | Olbert Catheter System for Biliary Tract Dilatatio | Meadox Surgimed, Inc. | 1985 | — |
| 0 (this device) | K973113 | Modified Olbert Balloon Catheter System, Noprofile Olbert Balloon Catheter… | Boston Scientific Corp | 1997 | — |
| +1 | K010714 | Expander, Models 1400880, 1401280, 1401680, 1401880, 1410420, 1410620, 1410830 | Medi-Globe Corp. | 2003 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1995 | 2 | 0 |
| 1996 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FGE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FGE device
- #1 K240464 WallFlex Biliary RX Stent System; Epic Biliary…score 14.5 · 13 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K934411 | Meadox Surgimed Olbert Catheter System NoprofileSummary page 3…lber Balloon Catheler | Vector TTS™ Balloon Bafloon Catheter i Modified End Connector Veclran Fibers for Biliary Dilatation Dilatation Catheter (This 510{k)) (510(k) No. K934411) (510(k) No. K945576) (510(k} No. K952867) (510(k) No. K851647) (510(k) No. K96 1438) USE .. Dilatation of Biliary and Dilatation… | 1994 |
| * | K945576 | Meadox Surgimed Noprofile (TM) Olbert Catheter System (R)Summary page 3…| Vector TTS™ Balloon Bafloon Catheter i Modified End Connector Veclran Fibers for Biliary Dilatation Dilatation Catheter (This 510{k)) (510(k) No. K934411) (510(k) No. K945576) (510(k} No. K952867) (510(k) No. K851647) (510(k) No. K96 1438) USE .. Dilatation of Biliary and Dilatation of Gl Indication Oth… | 1995 |
| * | K952887 | Noprofile Olbert Catheter System Balloon Dilatation Catheter Our OCR of the scanned summary read K952867, FDA’s number for Remanium:GM 700, GM 380, GM 800, GFH (Dentauraum, Inc.). Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “NoProfile®”. | 1995 |
| * | K851647 | Olbert Catheter System for Biliary Tract DilatatioSummary page 3…Modified End Connector Veclran Fibers for Biliary Dilatation Dilatation Catheter (This 510{k)) (510(k) No. K934411) (510(k) No. K945576) (510(k} No. K952867) (510(k) No. K851647) (510(k) No. K96 1438) USE .. Dilatation of Biliary and Dilatation of Gl Indication Other Non-GI Strictures «— Same «— Same a— Sa… | 1985 |
| * | K961438 | Ballon Dilatation CatheterSummary page 3…r Veclran Fibers for Biliary Dilatation Dilatation Catheter (This 510{k)) (510(k) No. K934411) (510(k) No. K945576) (510(k} No. K952867) (510(k) No. K851647) (510(k) No. K96 1438) USE .. Dilatation of Biliary and Dilatation of Gl Indication Other Non-GI Strictures «— Same «— Same a— Same «— Same Strictures… | 1996 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K010714 | Expander, Models 1400880, 1401280, 1401680, 1401880, 1410420, 1410620, 1410830 | 2003 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 5 ancestors has a recall.
- Of its descendants, K010714 (Medi-Globe Corp., 2003) has gone furthest, with 0 descendants of its own.
How does its category compare?
All FGE devicesFGE Stents, Drains And Dilators For The Biliary Ducts: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FGE
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FGE
257in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FGE
1in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FGE
1,923in 2025
MAUDE reports naming product code FGE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 316 | 54 | 1,006 |
| 2008 | 11 | 214 | 93 | 1,465 |
| 2009 | 7 | 160 | 18 | 1,655 |
| 2010 | 9 | 81 | 32 | 1,434 |
| 2011 | 9 | 114 | 2 | 1,321 |
| 2012 | 8 | 96 | 4 | 1,183 |
| 2013 | 5 | 161 | 3 | 1,060 |
| 2014 | 8 | 156 | 0 | 1,270 |
| 2015 | 8 | 79 | 0 | 1,543 |
| 2016 | 4 | 49 | 0 | 1,453 |
| 2017 | 9 | 59 | 1 | 1,515 |
| 2018 | 7 | 215 | 43 | 1,681 |
| 2019 | 2 | — | 13 | 1,896 |
| 2020 | 4 | 121 | 1 | 2,182 |
| 2021 | 1 | — | 27 | 2,297 |
| 2022 | 6 | 101 | 21 | 1,749 |
| 2023 | 6 | 199 | 19 | 1,615 |
| 2024 | 6 | 188 | 1 | 1,948 |
| 2025 | 7 | 257 | 0 | 1,923 |
| 2026 | 8 | 153 | 11 | — |
What is it indicated for?
The Modified Olbert® Balloon Catheter products are recommended for biliary tract stenosis/sphincter stenosis and gastrointestinal tract dilatation through a flexible endoscope. The recommended application is printed on the label *
* The recommended application on the label may refer to any combination of transpapillary, pyloric, colonic, anastomotic, and/or esophageal dilatation.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K973113 · printed Nov 5, 2026
Cite this page
510(k) Report. “K973113: Modified Olbert Balloon Catheter System, Noprofile Olbert Balloon Catheter System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K973113
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026