Coherent Popeye Ophthalmic Laser System, Coherent Popeye Ophthalmic Laser System in Combination with the Coherent Argons

K973470510(k) TraditionalCleared Dec 9, 199788-day reviewClass II21 CFR 878.4810

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Lumenis, Inc. · GEX Powered Laser Surgical Instrument

Cleared on Dec 9, 1997 as substantially equivalent to P830054 (Coherent Medical Division, 1984) and 8 other predicates after an 88-day review. Its family tree reaches back 1 generation to 1984. 8 later devices descend from it.

Decided
Dec 9, 1997
Review
88 days
Class
Class II
Product code
GEX
Recalls
None
Predicates
9

Its longest line of descent runs back 1 generation to P830054 (1984). 9 ancestors in all. 8 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1993: 1 other ancestor1991: 1 other ancestor1990: 2 other ancestors1989: 3 other ancestors1986: 1 other ancestor2003: 1 descendant cleared2005: 2 descendants cleared2006: 3 descendants cleared2009: 1 descendant cleared2012: 1 descendant clearedP830054 · Neodymium: Yag Ophthalmic Laser System 9900 · Coherent Medical Division · 198419801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 8 other ancestors 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 2 descendants4 generations forward: 2 descendants P830054 · Neodymium: Yag Ophthalmic Laser System 9900 · Coherent Medical Division · 19840
  1. Root · 1 generation backP830054 Neodymium: Yag Ophthalmic Laser System 9900Coherent Medical Division · 1984
  2. This deviceK973470 Coherent Popeye Ophthalmic Laser System, Coherent Popeye Ophthalmic…Lumenis, Inc. · 1997
  3. Descendant · cites it directly · 5 of its ownK032357 Novus TTX Laser and Delivery Devices with AccessoriesLumenis, Inc. · 2003
  4. Descendant · 2 generations on · 4 of its ownK052526 Novus 3000 Laser System and Delivery DevicesLumenis, Inc. · 2005
  5. Descendant · 3 generations on · 1 of its ownK062336 Optimedica Laser Indirect OphthalmoscopeOptimedica Corporation · 2006
  6. Descendant · 3 generations on · 1 of its ownK061025 Accutech Endolite ProbeAccutech Medical Technologies, Inc. · 2006
  7. Descendant · cites it directly · 1 of its ownK051944 Family of Selecta Ophthalmic Laser Systems (Selecta 1064, Selecta…Lumenis, Inc. · 2005

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2003: 12005: 22006: 32009: 12012: 1
2003high 3 (2006) · low 0 (2004)2026

Most influential descendants

Showing 5 of 8 · See all
  • K032357Novus TTX Laser and Delivery Devices with AccessoriesLumenis, Inc. · 2003 · cites it directly5descendants
  • K052526Novus 3000 Laser System and Delivery DevicesLumenis, Inc. · 2005 · 2 generations on4descendants
  • K062336Optimedica Laser Indirect OphthalmoscopeOptimedica Corporation · 2006 · 3 generations on1descendant
  • K061025Accutech Endolite ProbeAccutech Medical Technologies, Inc. · 2006 · 3 generations on1descendant
  • K051944Family of Selecta Ophthalmic Laser Systems (Selecta 1064, Selecta SLT, Selecta Duo)…Lumenis, Inc. · 2005 · cites it directly1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1P830054Neodymium: Yag Ophthalmic Laser System 9900Coherent Medical Division1984—
0 (this device)K973470Coherent Popeye Ophthalmic Laser System, Coherent Popeye Ophthalmic Laser…Lumenis, Inc.1997—
+1K032357Novus TTX Laser and Delivery Devices with AccessoriesLumenis, Inc.2003—
+2K052526Novus 3000 Laser System and Delivery DevicesLumenis, Inc.2005—
+3K062336Optimedica Laser Indirect OphthalmoscopeOptimedica Corporation2006—
+3K061025Accutech Endolite ProbeAccutech Medical Technologies, Inc.2006—
+1K051944Family of Selecta Ophthalmic Laser Systems (Selecta 1064, Selecta SLT, Selecta…Lumenis, Inc.2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
198930
199020
199110
199310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
200520
200630
200910
201210
FIG. 1 — Lineage of K973470, 1984–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GEX device

  1. #1 K222064 The Alma Soprano Titaniumscore 38.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (9)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*P830054Neodymium: Yag Ophthalmic Laser System 9900
Summary page 1
…E Argon Laser Photocoagulator Primary Classification Name: Nd: YAG laser for posterior capsulotomy; and Ophthalmic laser Predicate Devices Coherent 7970 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Coherent 7901 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Nidek YC-1200 Ophthalmic YAG Laser (K8939…
Coherent Medical Division1984—
*K893987Nidek Model YC-1200
Summary page 1
…Devices Coherent 7970 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Coherent 7901 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Nidek YC-1200 Ophthalmic YAG Laser (K893987; K901481); Lasag Microruptor 2 Nd:YAG Ophthalmic (P840012, K885164); Zeiss Visulas YAG II Laser (K926452); Alcon 3000LE Nd:YAG…
Nidek, Inc.19891
*K901481Model YC-1200/Photocoagulator Ophthalmic Laser
Summary page 1
…Coherent 7970 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Coherent 7901 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Nidek YC-1200 Ophthalmic YAG Laser (K893987; K901481); Lasag Microruptor 2 Nd:YAG Ophthalmic (P840012, K885164); Zeiss Visulas YAG II Laser (K926452); Alcon 3000LE Nd:YAG Ophthalm…
Nidek, Inc.1990—
*P840012Microruptor MR-2 ND:Yag Laser System
Summary page 1
…-S19, §22); Coherent 7901 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Nidek YC-1200 Ophthalmic YAG Laser (K893987; K901481); Lasag Microruptor 2 Nd:YAG Ophthalmic (P840012, K885164); Zeiss Visulas YAG II Laser (K926452); Alcon 3000LE Nd:YAG Ophthalmic Laser System (K897099); Coherent Novus 2000/ N…
Meridian AG1986—
*K885164Lasag Microruptor 2 ND:Yag Ophth. Laser System
Summary page 1
…); Coherent 7901 Nd:YAG Laser (P830054/513, S14, S17-S19, §22); Nidek YC-1200 Ophthalmic YAG Laser (K893987; K901481); Lasag Microruptor 2 Nd:YAG Ophthalmic (P840012, K885164); Zeiss Visulas YAG II Laser (K926452); Alcon 3000LE Nd:YAG Ophthalmic Laser System (K897099); Coherent Novus 2000/ Nd: YAG La…
Chiron Vision Corp.1989—
*K926452Zeiss Visulas Yag II Laser
Summary page 1
…/513, S14, S17-S19, §22); Nidek YC-1200 Ophthalmic YAG Laser (K893987; K901481); Lasag Microruptor 2 Nd:YAG Ophthalmic (P840012, K885164); Zeiss Visulas YAG II Laser (K926452); Alcon 3000LE Nd:YAG Ophthalmic Laser System (K897099); Coherent Novus 2000/ Nd: YAG Laser System (K893709, P830054/522); Ulti…
Carl Zeiss, Inc.1993—
*K897099Model 2800 ND:Yag Ophthalmic Laser
Summary page 1
…Laser (K893987; K901481); Lasag Microruptor 2 Nd:YAG Ophthalmic (P840012, K885164); Zeiss Visulas YAG II Laser (K926452); Alcon 3000LE Nd:YAG Ophthalmic Laser System (K897099); Coherent Novus 2000/ Nd: YAG Laser System (K893709, P830054/522); Ultima 2000 and 2000SE Argon Laser Photocoagulators (K913127…
Alcon Surgical, Inc.1990—
*K893709Coherent Marie Argon Photocoagulator
Summary page 1
…Ophthalmic (P840012, K885164); Zeiss Visulas YAG II Laser (K926452); Alcon 3000LE Nd:YAG Ophthalmic Laser System (K897099); Coherent Novus 2000/ Nd: YAG Laser System (K893709, P830054/522); Ultima 2000 and 2000SE Argon Laser Photocoagulators (K913127); Nidek Ophthalmic Models YC-1200/Photocoagulator Co…
Coherent Medical Group1989—
*K913127Coherent Novus 3000 Argon Photocoagulator
Summary page 1
…3000LE Nd:YAG Ophthalmic Laser System (K897099); Coherent Novus 2000/ Nd: YAG Laser System (K893709, P830054/522); Ultima 2000 and 2000SE Argon Laser Photocoagulators (K913127); Nidek Ophthalmic Models YC-1200/Photocoagulator Combination Ophthalmic Laser (K901481). 510(k) Coherent Popeye Ophthalmic Las…
Coherent Medical Group1991—

What descends from it? (8)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K032357Novus TTX Laser and Delivery Devices with AccessoriesLumenis, Inc.20035
K051944Family of Selecta Ophthalmic Laser Systems (Selecta 1064, Selecta SLT, Selecta Duo)…Lumenis, Inc.20051

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 9 ancestors has a recall of any class.
  • Of its descendants, K032357 (Lumenis, Inc., 2003) has gone furthest, with 5 descendants of its own.

How does its category compare?

All GEX devices

GEX Powered Laser Surgical Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GEX

83in 2025

2007: 732008: 1072009: 692010: 502011: 412012: 452013: 462014: 612015: 472016: 512017: 672018: 512019: 412020: 522021: 532022: 602023: 522024: 822025: 832026 (partial year): 57
2007high 107 (2008) · low 41 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GEX

90in 2025

2007: 79 days median2008: 86 days median2009: 100 days median2010: 96 days median2011: 83 days median2012: 118 days median2013: 144 days median2014: 147 days median2015: 112 days median2016: 114 days median2017: 90 days median2018: 78 days median2019: 88 days median2020: 90 days median2021: 123 days median2022: 152 days median2023: 87 days median2024: 90 days median2025: 90 days median2026 (partial year): 90 days median
2007high 152 (2022) · low 78 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GEX

3in 2024

2007: 92008: 22010: 42011: 182012: 52013: 32014: 62016: 12017: 5, 1 Class I2018: 52019: 62020: 12023: 62024: 32026 (partial year): 2
2007high 18 (2011) · low 0 (2009)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GEX

2,720in 2025

2007: 3422008: 2322009: 2092010: 1,7112011: 3,0242012: 2,0002013: 2,2362014: 2,0362015: 2,0992016: 2,5852017: 2,9772018: 3,5252019: 2,7092020: 2,1832021: 3,4652022: 2,2882023: 2,3372024: 2,1872025: 2,720
2007high 3,525 (2018) · low 209 (2009)2025

MAUDE reports naming product code GEX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200773799342
2008107862232
2009691000209
2010509641,711
20114183183,024
20124511852,000
20134614432,236
20146114762,036
20154711202,099
20165111412,585
201767905 (1)2,977
2018517853,525
2019418862,709
2020529012,183
20215312303,465
20226015202,288
2023528762,337
2024829032,187
2025839002,720
202657902—

What is it indicated for?

The Coherent Popeye Ophthalmic Laser is indicated for use in photodisruption of ocular tissue using laser energy emitted by a Nd:YAG laser. These indications include: discission of the posterior capsule of the eye (posterior capsulotomy) discission of pupillary membranes (pupillary membranectomy) in aphakic and pseudophakic patients The Coherent Popeye Ophthalmic Laser in Combination with the Ultima 2000 or Ultima 2000SE Argon Photocoagulator is…

Read the full statement (305 words)

The Coherent Popeye Ophthalmic Laser is indicated for use in photodisruption of ocular tissue using laser energy emitted by a Nd:YAG laser. These indications include:

discission of the posterior capsule of the eye (posterior capsulotomy)

discission of pupillary membranes (pupillary membranectomy) in aphakic and pseudophakic patients

The Coherent Popeye Ophthalmic Laser in Combination with the Ultima 2000 or Ultima 2000SE Argon Photocoagulator is indicated for:

a. Popeye Nd:YAG 1064 nm wavelength - Indicated for use in photodisruption of ocular tissue using laser energy emitted by a Nd:YAG laser. These indications include:

o discission of the posterior capsule of the eye (posterior capsulotomy) and;

e discission of pupillary membranes (pupillary membranectomy) in aphakic and pseudophakic patients.

b. Ultima 2000/Ultima 2000SE - Indicated for use in the treatment of ocular pathology using blue-green and green argon laser energy. These indications include:

e photocoagulation of both anterior and posterior segments including:

e iridotomy, iridectomy and trabeculoplasty in angle closure glaucoma and open angle glaucoma;

e retinal photocoagulation, panretinal photocoagulation and intravitreal endophotocoagulation of vascular and structural abnormalities of the retina and choroid including;

- diabetic retinopathy;

- choroidal neovascularization;

- branch retinal vein occlusion;

- subretinal neovascularization in disciform macular degeneration.

The Coherent Popeye Ophthalmic Laser in Combination with the Ultima 2000 or Ultima 2000SE Argon Photocoagulator (Indications continued)

Laser Indirect Ophthalmoscope

The Laser Indirect Ophthalmoscope is indicated for use in the following ophthalmic treatments:

o diabetic retinopathy (pan-retinal photocoagulation);

e retinopexy;

e segmental peripheral photocoagulation;

e segmental photocoagulation;

¢ cloudy vitreous cavities; and,

o pediatric retinal repairs (under general anesthesia)

Acculite Endoprobe

The Acculite Endoprobe is indicated for use in the following ophthalmic applications:

¢ photocoagulation of the anterior and posterior segment, including:

- anterior segment treatment in the surgical management of glaucoma;

- endophotocoagulation in vitreoretinal surgery - including panretinal photocoagulation, retinopexy, and treatment of neovascularization.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K973470: Coherent Popeye Ophthalmic Laser System, Coherent Popeye Ophthalmic Laser System in Combination with the Coherent Argons.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K973470

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026