510(k) · Cleared
Recalled · Class III · 2016Sangui Biotech, Inc. Intact-PTH (Parathyroid Hormone) Elisa
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Sangui Biotech, Inc. · CEW Radioimmunoassay, Parathyroid Hormone
Cleared on Dec 23, 1997 after a 36-day review. The FDA summary names its predicate without a number. It has been recalled once.
- Decided
- Dec 23, 1997
- Review
- 36 days
- Class
- Class II
- Product code
- CEW
- Recalls
- 1
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CEW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CEW device
- #1 K231927 Elecsys PTH , Elecsys PTH STATscore 7.6 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Nichols Institute Diagnostics Allegro® Intact PTH (Parathyroid Hormone) kit Named without a submission number | |
| * | — | ACTIVE™ I-PTH ELISA kit Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Oct 26, 2016 | Class III | Z-1520-2018 | Nonconforming Material/Component | There may be a loss of separation between Calibrators A and B which may impact the assay calibration at the lower end of the assay. |
No ancestor or descendant has a Class I recall.
How does its category compare?
All CEW devicesCEW Radioimmunoassay, Parathyroid Hormone: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CEW
2in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · CEW
160in 2007
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CEW
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · CEW
37in 2025
MAUDE reports naming product code CEW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 160 | 1 | 0 |
| 2008 | 0 | — | 1 | 8 |
| 2009 | 0 | — | 0 | 4 |
| 2010 | 1 | — | 3 | 23 |
| 2011 | 0 | — | 0 | 97 |
| 2012 | 1 | — | 0 | 124 |
| 2013 | 2 | — | 1 | 172 |
| 2014 | 1 | — | 0 | 167 |
| 2015 | 1 | — | 0 | 57 |
| 2016 | 0 | — | 2 | 98 |
| 2017 | 2 | — | 0 | 83 |
| 2018 | 0 | — | 0 | 65 |
| 2019 | 1 | — | 0 | 77 |
| 2020 | 0 | — | 0 | 50 |
| 2021 | 0 | — | 0 | 57 |
| 2022 | 0 | — | 2 | 188 |
| 2023 | 1 | — | 0 | 82 |
| 2024 | 2 | — | 2 | 67 |
| 2025 | 0 | — | 1 | 37 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The intended use of this product is the quantitative determination of Intact Parathyroid Hormone (PTH) in human serum. This immunoassay is based on the principles of the two site “sandwich” Enzyme-Linked ImmunoSorbent Assay (ELISA). The measurement of parathyroid hormone levels in the disease states is intended for the differential diagnosis of hypercalcemia and hypocalcemia resulting from the disorders of calcium metabolism.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K974306 · printed Nov 6, 2026
Cite this page
510(k) Report. “K974306: Sangui Biotech, Inc. Intact-PTH (Parathyroid Hormone) Elisa.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K974306
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)