510(k) Report

510(k) · Cleared

Cleared

Discam Digital Imaging System

K974535510(k) TraditionalCleared Aug 14, 1998255-day reviewClass II21 CFR 886.1120

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Marcher Enterprises, Ltd. · HKI Camera, Ophthalmic, Ac-Powered

Cleared on Aug 14, 1998 as substantially equivalent to K954780 (Kowa Optimed, Inc., 1995) and 3 other predicates after a 255-day review. Its family tree reaches back 1 generation to 1991. 3 later devices descend from it.

Decided
Aug 14, 1998
Review
255 days
Class
Class II
Product code
HKI
Recalls
None
Predicates
4

Its longest line of descent runs back 1 generation to K912891 (1991). 4 ancestors in all. 3 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1995: 1 other ancestor1993: 1 other ancestor1991: 1 other ancestor2011: 1 descendant cleared2012: 1 descendant cleared2023: 1 descendant clearedK912891 · Heidelberg Retina Tomograph · Heidelberg Engineering · 19911990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 1 descendant K912891 · Heidelberg Retina Tomograph · Heidelberg Engineering · 19910
  1. Root · 1 generation backK912891 Heidelberg Retina TomographHeidelberg Engineering · 1991
  2. This deviceK974535 Discam Digital Imaging SystemMarcher Enterprises, Ltd. · 1998
  3. Descendant · cites it directly · 2 of its ownK102412 Vista Digital OpthalmoscopeEyequick.Llc · 2011
  4. Descendant · 2 generations on · 1 of its ownK121405 PanopticWelch Allyn, Inc. · 2012
  5. Descendant · 3 generations on · 0 of its ownK223381 iExaminer System with Panoptic PlusWelch Allyn, Inc. · 2023

Most influential descendants

Showing 3 of 3 · See all
  • K102412Vista Digital OpthalmoscopeEyequick.Llc · 2011 · cites it directly2descendants
  • K121405PanopticWelch Allyn, Inc. · 2012 · 2 generations on1descendant
  • K223381iExaminer System with Panoptic PlusWelch Allyn, Inc. · 2023 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K912891Heidelberg Retina TomographHeidelberg Engineering1991—
0 (this device)K974535Discam Digital Imaging SystemMarcher Enterprises, Ltd.1998—
+1K102412Vista Digital OpthalmoscopeEyequick.Llc2011—
+2K121405PanopticWelch Allyn, Inc.2012—
+3K223381iExaminer System with Panoptic PlusWelch Allyn, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199310
199510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
202310
FIG. 1 — Lineage of K974535, 1991–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HKI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HKI device

  1. #1 K253176 TearViewscore 12.8 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K954780Kowa Professional Fundus Camera Models FX-500, FX-500S, FX-500C
Summary page 1
…me: Ophthalmic Digital Camera Classification Name: Camera, Ophthalmic, AC-Powered Predicate Device » KOWA OPTIMED, INC.: KOWA PROFESSIONAL FUNDUS CAMERA MODELS EX-500 (K954780, cleared 12/01/95) ¢ OPHTHALMIC IMAGING SYSTEMS, INC.: DFC-512 DIGITAL IMAGING SYSTEM (K913929, cleared 11/27/91) * LASER DIAGN…
Kowa Optimed, Inc.1995—
*K913929DFC-1024 & DFC-512 Digital Imaging System
Summary page 1
…ice » KOWA OPTIMED, INC.: KOWA PROFESSIONAL FUNDUS CAMERA MODELS EX-500 (K954780, cleared 12/01/95) ¢ OPHTHALMIC IMAGING SYSTEMS, INC.: DFC-512 DIGITAL IMAGING SYSTEM (K913929, cleared 11/27/91) * LASER DIAGNOSTIC TECHNOLOGIES, INC.: TOPOGRAPHIC SCANNING SYSTEM (K923742, cleared 03/26/93) * HEIDELBERG…
Ophthalmic Imaging Systems19915
*K923742Topographic Scanning System Topss
Summary page 1
…/95) ¢ OPHTHALMIC IMAGING SYSTEMS, INC.: DFC-512 DIGITAL IMAGING SYSTEM (K913929, cleared 11/27/91) * LASER DIAGNOSTIC TECHNOLOGIES, INC.: TOPOGRAPHIC SCANNING SYSTEM (K923742, cleared 03/26/93) * HEIDELBERG ENGINEERING: HEIDELBERG RETINA TOMOGRAPH (K912891, cleared 09/27/91) 510(k) SUMMARY OF SAFETY A…
Carl Zeiss Meditec, Inc.1993—
*K912891Heidelberg Retina Tomograph
Summary page 1
…cleared 11/27/91) * LASER DIAGNOSTIC TECHNOLOGIES, INC.: TOPOGRAPHIC SCANNING SYSTEM (K923742, cleared 03/26/93) * HEIDELBERG ENGINEERING: HEIDELBERG RETINA TOMOGRAPH (K912891, cleared 09/27/91) 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS MARCHER ENTERPRISES, LTD. DISCAM® DIGITAL IMAGING SYSTEM Page 1…
Heidelberg Engineering1991—

Also cleared against K954780: 2 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K102412Vista Digital OpthalmoscopeEyequick.Llc20112

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 4 ancestors has a recall of any class.
  • Of its descendants, K102412 (Eyequick.Llc, 2011) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K954780.

How does its category compare?

All HKI devices

HKI Camera, Ophthalmic, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HKI

4in 2025

2007: 22008: 52009: 112010: 62011: 72012: 52013: 72014: 42016: 42017: 22018: 62019: 42020: 52021: 42022: 12023: 52024: 32025: 42026 (partial year): 2
2007high 11 (2009) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HKI

167in 2025

2008: 29 days median2009: 104 days median2010: 140 days median2011: 160 days median2012: 179 days median2013: 141 days median2014: 135 days median2016: 146 days median2018: 71 days median2019: 73 days median2020: 182 days median2021: 155 days median2023: 259 days median2024: 28 days median2025: 167 days median
2007high 259 (2023) · low 28 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HKI

1in 2018

2012: 12016: 12017: 12018: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HKI

1in 2023

2007: 32008: 12009: 12012: 22013: 222014: 32015: 32016: 662017: 202018: 142020: 52021: 32022: 12023: 1
2007high 66 (2016) · low 0 (2010)2025

MAUDE reports naming product code HKI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—03
200852901
20091110401
2010614000
2011716000
2012517912
20137141022
2014413503
20150—03
20164146166
20172—120
2018671114
201947300
2020518205
2021415503
20221—01
2023525901
202432800
2025416700
20262—0—

What is it indicated for?

The Discam® Digital Imaging System is intended to be used to evaluate the Optic Disc, (Optic Nerve Head). It is used in the same fashion as a Fundus camera, except that it's field of view is narrower, in order to focus exclusively on the Optic Disc, (Optic Nerve Head). Evaluation of changes in the size and shape of the Optic Disc, (Optic Nerve Head), is useful in monitoring the progress of patients with Ocular Hypertension, and Glaucoma.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K974535: Discam Digital Imaging System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K974535

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026