510(k) · Cleared
ClearedFukuda Denshi Model HC-500 End Tidal CO2 Module
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Fukuda Denshi USA, Inc. · CCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase
Cleared on Jun 12, 1998 as substantially equivalent to K950044 (Fukuda Denshi USA, Inc., 1995) after an 87-day review. Its family tree reaches back 1 generation to 1995.
- Decided
- Jun 12, 1998
- Review
- 87 days
- Class
- Class II
- Product code
- CCK
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K950044 (1995). No later device cites it as a predicate yet.
- Root · 1 generation backK950044 Fukuda Denshi Model HC-300 End Tidal CO2 ModuleFukuda Denshi USA, Inc. · 1995
- This deviceK980979 Fukuda Denshi Model HC-500 End Tidal CO2 ModuleFukuda Denshi USA, Inc. · 1998
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K950044 | Fukuda Denshi Model HC-300 End Tidal CO2 Module | Fukuda Denshi USA, Inc. | 1995 | — |
| 0 (this device) | K980979 | Fukuda Denshi Model HC-500 End Tidal CO2 Module | Fukuda Denshi USA, Inc. | 1998 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CCK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CCK device
- #1 K253030 Capnostream™35 Portable Respiratory Monitor…score 15.8 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K950044 | Fukuda Denshi Model HC-300 End Tidal CO2 ModuleSummary page 1…TCO, Gas Module Classification Name: Carbon Dioxide Gas Analyzer (§869.1400) Legally Marketed Device: : FUKUDA DENSHI niiodel HC-300 End Tidal CO, Module 510(k) number K950044. (The HC-500 is an addition to the to the DS-5300, 510(k), K964187.) HC-500 510(k) Submission March 9, 1998 Section 2.doc Page 1… | 1995 |
| † | K964187 | Fukada Denshi Dynascope Model DS-5300 Patient Monitor | 1997 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
How does its category compare?
All CCK devicesCCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CCK
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · CCK
169in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CCK
1in 2022
Class I (8 since 2007) Class II/III not classified
Adverse event reports per year · CCK
1,259in 2025
MAUDE reports naming product code CCK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 56 | 0 | 7 |
| 2008 | 3 | 248 | 1 | 20 |
| 2009 | 3 | 101 | 19 | 21 |
| 2010 | 3 | 125 | 4 | 12 |
| 2011 | 2 | — | 14 | 18 |
| 2012 | 7 | 150 | 3 | 13 |
| 2013 | 4 | 132 | 2 (1) | 28 |
| 2014 | 9 | 166 | 0 | 51 |
| 2015 | 5 | 105 | 1 | 114 |
| 2016 | 2 | — | 0 | 88 |
| 2017 | 5 | 134 | 0 | 58 |
| 2018 | 6 | 296 | 5 | 63 |
| 2019 | 7 | 261 | 7 (7) | 141 |
| 2020 | 4 | 188 | 1 | 2,302 |
| 2021 | 4 | 227 | 0 | 2,272 |
| 2022 | 3 | 226 | 1 | 2,475 |
| 2023 | 4 | 555 | 0 | 1,637 |
| 2024 | 3 | 592 | 0 | 1,216 |
| 2025 | 3 | 169 | 0 | 1,259 |
| 2026 | 3 | 224 | 0 | — |
What is it indicated for?
The Fukuda Denshi model HC-500 End Tidal CO2 Module is indicated in those situation where it is desirable to perform real-time end tidal or inspired carbon dioxide concentration and/or respiration rate monitoring of intubated adult, infant and/or neonate patients who are under the care of a physician, within the confines of a health care facility.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K980979 · printed Nov 6, 2026
Cite this page
510(k) Report. “K980979: Fukuda Denshi Model HC-500 End Tidal CO2 Module.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K980979
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026