510(k) Report

510(k) · Cleared

Recalled · Class I · 2018

Vacutainer Plus Tube with Edta Anticoagulant Andd Vacutainer Plus Serum Tube

K981013510(k) TraditionalCleared Jun 17, 199891-day reviewClass II21 CFR 862.1675Recalls 8 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton Dickinson Vacutainer Systems · JKA Tubes, Vials, Systems, Serum Separators, Blood Collection

Cleared on Jun 17, 1998 after a 91-day review. The FDA summary names its predicate without a number. 1 of the 3 devices in its family, counting itself, has a Class I recall. 2 later devices descend from it. It has been recalled 8 times, including 2 Class I recalls.

Decided
Jun 17, 1998
Review
91 days
Class
Class II
Product code
JKA
Recalls
8 (2 Class I)
Predicates
0

2 later devices descend from it, 2 citing it directly. 1 of the 3 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2023: 1 descendant cleared2024: 1 descendant cleared1995200020052010201520202025
  1. This deviceK981013 Vacutainer Plus Tube with Edta Anticoagulant Andd Vacutainer Plus…Becton Dickinson Vacutainer Systems · 1998
  2. Descendant · cites it directly · 0 of its ownK231373 BD Vacutainer® K2 EDTA Blood Collection TubesBecton, Dickinson and Company · 2024
  3. Descendant · cites it directly · 0 of its ownK213670 BD Vacutainer K2EDTA Blood Collection Tubes, BD Vacutainer K3EDTA…Becton, Dickinson and Company · 2023

Most influential descendants

Showing 2 of 2 · See all
  • K231373BD Vacutainer® K2 EDTA Blood Collection TubesBecton, Dickinson and Company · 2024 · cites it directly0descendants
  • K213670BD Vacutainer K2EDTA Blood Collection Tubes, BD Vacutainer K3EDTA Blood Collection TubesBecton, Dickinson and Company · 2023 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K981013Vacutainer Plus Tube with Edta Anticoagulant Andd Vacutainer Plus Serum TubeBecton Dickinson Vacutainer Systems1998—
+1K231373BD Vacutainer® K2 EDTA Blood Collection TubesBecton, Dickinson and Company2024—
+1K213670BD Vacutainer K2EDTA Blood Collection Tubes, BD Vacutainer K3EDTA Blood…Becton, Dickinson and Company2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202410
FIG. 1 — Lineage of K981013, 1998–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JKA device

  1. #1 K200027 Blood Collection Needle with/without Holder…score 15.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—VACUTAINER® Brand Serum Tube
Named without a submission number
—
*—VACUTAINER® Brand Tube with EDTA Anticoagulant
Named without a submission number
—

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K231373BD Vacutainer® K2 EDTA Blood Collection TubesBecton, Dickinson and Company20240
K213670BD Vacutainer K2EDTA Blood Collection Tubes, BD Vacutainer K3EDTA Blood Collection TubesBecton, Dickinson and Company20230

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 22, 2018Class IZ-1139-2018Device DesignBD Vacutainer EDTA Lavender, Tan, and Pink Top Tubes and BD Vacutainer Lithium Heparin Green Top Tubes can cause an underestimation of lead in blood samples when used with Magellan Diagnostics LeadCare assays, employing the Anodic…
Mar 22, 2018Class IZ-1141-2018Device DesignBD Vacutainer EDTA Lavender, Tan, and Pink Top Tubes and BD Vacutainer Lithium Heparin Green Top Tubes can cause an underestimation of lead in blood samples when used with Magellan Diagnostics LeadCare assays, employing the Anodic…
Dec 3, 2015Class IIZ-0571-2016Process change controlSome of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.
Dec 3, 2015Class IIZ-0567-2016Process change controlSome of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.
Dec 3, 2015Class IIZ-0568-2016Process change controlSome of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.
Dec 3, 2015Class IIZ-0569-2016Process change controlSome of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.
Dec 3, 2015Class IIZ-0570-2016Process change controlSome of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.
Nov 17, 2015Class IIZ-0456-2016Under Investigation by firmSome tubes were manufactured with the stopper not fully inserted into the tube. This may result in the stopper popping-off in a small number of instances which could lead to blood exposure and in some cases to blood splatter or spraying.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K231373 (Becton, Dickinson and Company, 2024) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JKA devices

JKA Tubes, Vials, Systems, Serum Separators, Blood Collection: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JKA

7in 2025

2007: 42008: 22009: 22010: 42012: 12013: 32014: 12015: 12016: 42017: 22018: 12019: 62020: 62021: 42022: 92023: 172024: 62025: 72026 (partial year): 8
2007high 17 (2023) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JKA

115in 2025

2007: 281 days median2010: 28 days median2013: 244 days median2016: 116 days median2019: 181 days median2020: 181 days median2021: 217 days median2022: 164 days median2023: 189 days median2024: 240 days median2025: 115 days median2026 (partial year): 250 days median
2007high 281 (2007) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JKA

13in 2025

2007: 32008: 32009: 32010: 42011: 142012: 22013: 12014: 12015: 62016: 12017: 22018: 22019: 92021: 32022: 22023: 22025: 132026 (partial year): 1
2007high 14 (2011) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JKA

6,089in 2025

2007: 732008: 782009: 422010: 372011: 672012: 542013: 332014: 682015: 412016: 652017: 2,0392018: 9,7312019: 6,4692020: 3,7742021: 3,6102022: 3,3752023: 4,4002024: 4,6092025: 6,089
2007high 9,731 (2018) · low 33 (2013)2025

MAUDE reports naming product code JKA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074281373
20082—378
20092—342
2010428437
20110—1467
20121—254
20133244133
20141—168
20151—641
20164116165
20172—22,039
20181—29,731
2019618196,469
2020618103,774
2021421733,610
2022916423,375
20231718924,400
2024624004,609
20257115136,089
202682501—

What is it indicated for?

The VACUTAINER® Brand PLUS (plastic) Tube with EDTA and VACUTAINER® Brand Serum Tube are evacuated blood collection tubes which provide a means of collecting, transporting, separating and processing blood in a plastic tube. When the tube is used together with VACUTAINER® Brand Needles and Holders, it is a closed system for the collection of venous blood with the same indications as described herein.

Blood collected in PLUS EDTA and PLUS Serum tubes can be used for inmunohematology testing including ABO Grouping, Rh typing and antibody screening which requires red cells and plasma or serum.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K981013: Vacutainer Plus Tube with Edta Anticoagulant Andd Vacutainer Plus Serum Tube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K981013

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026