510(k) Report

510(k) · Cleared

Recalled · Class II · 2021

Better-Bladder (BB)

K981284510(k) TraditionalCleared Aug 12, 1998126-day reviewClass II21 CFR 870.4400Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Circulatory Technology, Inc. · DTN Reservoir, Blood, Cardiopulmonary Bypass

Cleared on Aug 12, 1998 after a 126-day review. The FDA summary names its predicate without a number. 1 later device descends from it. It has been recalled 7 times.

Decided
Aug 12, 1998
Review
126 days
Class
Class II
Product code
DTN
Recalls
7
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared1995200020052010201520202025
  1. This deviceK981284 Better-Bladder (BB)Circulatory Technology, Inc. · 1998
  2. Descendant · cites it directly · 0 of its ownK140321 Initary Better Bladder-PediatricCirculatory Technology, Inc. · 2014

Most influential descendants

Showing 1 of 1 · See all
  • K140321Initary Better Bladder-PediatricCirculatory Technology, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K981284Better-Bladder (BB)Circulatory Technology, Inc.1998—
+1K140321Initary Better Bladder-PediatricCirculatory Technology, Inc.2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
FIG. 1 — Lineage of K981284, 1998–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DTN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DTN device

  1. #1 K251783 Inspire HCR and HCR DUAL cardiotomy reservoirsscore 12.3 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Pressure Monitoring Separator Chamber (PMS-2)
Named without a submission number
—
*—R30 Assist Reservoir
Named without a submission number
—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K140321Initary Better Bladder-PediatricCirculatory Technology, Inc.20140

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 27, 2021Class IIZ-1862-2021Process controlThe device is used as part of extracorporeal membrane oxygenation (ECMO) cardiopulmonary bypass circuits and may collapse during use which can increase resistance to flow in the venous line and cause a drop in circuit blood flow.
Sep 22, 2017Class IIZ-0817-2018Process controlThe device is used as part of extracorporeal membrane oxygenation (ECMO) cardiopulmonary bypass circuits and may collapse during use which can increase resistance to flow in the venous line and cause a drop in circuit blood flow.
Sep 22, 2017Class IIZ-1171-2018Process controlThe device is used as part of extracorporeal membrane oxygenation (ECMO) cardiopulmonary bypass circuits and may collapse during use which can increase resistance to flow in the venous line and cause a drop in circuit blood flow.
Jul 1, 2016Class IIIZ-0057-2017Use errorTwisted or wrinkled balloon components which are considered a cosmetic defect by the firm.
Jul 1, 2016Class IIZ-2832-2016Device DesignThe seal between the balloon and the housing may leak.
Mar 3, 2016Class IIZ-2050-2016Device DesignThe seal between the balloon and the housing may leak.
Jun 3, 2009Not classifiedZ-1323-2010Process controlDuring an FDA inspection, it was discovered that the firm had conducted a silent recall of its Bigger Better Bladder device after receiving a complaint from a hospital that the device collapsed during a procedure thereby obstructing flow.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K140321 (Circulatory Technology, Inc., 2014) has gone furthest, with 0 descendants of its own.

How does its category compare?

All DTN devices

DTN Reservoir, Blood, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DTN

1in 2025

2007: 22008: 12009: 72010: 12011: 22013: 42014: 32015: 22017: 22023: 12024: 22025: 1
2007high 7 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DTN

38in 2014

2009: 211 days median2013: 79 days median2014: 38 days median
2007high 211 (2009) · low 38 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DTN

2in 2018

2007: 12008: 12009: 12011: 12016: 12017: 12018: 2
2007high 2 (2018) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DTN

8in 2025

2007: 102008: 82009: 102010: 182011: 102012: 172013: 472014: 522015: 272016: 62017: 32018: 42019: 112020: 62021: 122022: 72023: 82024: 102025: 8
2007high 52 (2014) · low 3 (2017)2025

MAUDE reports naming product code DTN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—110
20081—18
20097211110
20101—018
20112—110
20120—017
2013479047
2014338052
20152—027
20160—16
20172—13
20180—24
20190—011
20200—06
20210—012
20220—07
20231—08
20242—010
20251—08
20260—0—

What is it indicated for?

The Better-Bladder™ is a device that isolates pressure transducers from blood contact when measurements of blood pressure in extracorporeal circuits are made during short and long term procedures. The pressure signal can be used to control pump speed. It is also used as an inline reservoir to provide compliance in the circuit during short and long term procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K981284: Better-Bladder (BB).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K981284

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026