510(k) Report

510(k) · Cleared

Cleared

GT Leggiero

K981359510(k) TraditionalCleared Jan 27, 1999288-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Terumo Medical Corp. · DQY Catheter, Percutaneous

Cleared on Jan 27, 1999 as substantially equivalent to K915414 (Terumo Medical Corp., 1992) after a 288-day review. Its family tree reaches back 1 generation to 1992. 14 later devices descend from it.

Decided
Jan 27, 1999
Review
288 days
Class
Class II
Product code
DQY
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K915414 (1992). 14 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared2024: 1 descendant cleared2004: 1 descendant cleared2018: 2 descendants cleared2017: 2 descendants cleared2015: 1 descendant cleared2021: 1 descendant cleared2016: 1 descendant cleared2020: 2 descendants cleared2023: 1 descendant cleared2022: 1 descendant clearedK915414 · Terumo Angiogtaphic Catheter · Terumo Medical Corp. · 19921990200020102020
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 6 descendants3 generations forward: 6 descendants4 generations forward: 1 descendant K915414 · Terumo Angiogtaphic Catheter · Terumo Medical Corp. · 19920
  1. Root · 1 generation backK915414 Terumo Angiogtaphic CatheterTerumo Medical Corp. · 1992
  2. This deviceK981359 GT LeggieroTerumo Medical Corp. · 1999
  3. Descendant · cites it directly · 13 of its ownK033583 ProgreatTerumo Medical Corp. · 2003
  4. Descendant · 2 generations on · 3 of its ownK173430 SeQure® NF and SeQure® MicrocathetersAccurate Medical Therapeutics, Ltd. · 2018
  5. Descendant · 2 generations on · 3 of its ownK033913 ProgreatTerumo Medical Corp. · 2004
  6. Descendant · 3 generations on · 2 of its ownK202797 Drakon and Sequre MicrocathetersAccurate Medical Therapeutics, Ltd. · 2020
  7. Descendant · 3 generations on · 1 of its ownK203487 Drakon and Sequre MicrocathetersAccurate Medical Therapeutics, Ltd. · 2020

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2003: 12004: 12015: 12016: 12017: 22018: 22020: 22021: 12022: 12023: 12024: 1
2003high 2 (2017) · low 0 (2005)2026

Most influential descendants

Showing 5 of 14 · See all
  • K033583ProgreatTerumo Medical Corp. · 2003 · cites it directly13descendants
  • K173430SeQure® NF and SeQure® MicrocathetersAccurate Medical Therapeutics, Ltd. · 2018 · 2 generations on3descendants
  • K033913ProgreatTerumo Medical Corp. · 2004 · 2 generations on3descendants
  • K202797Drakon and Sequre MicrocathetersAccurate Medical Therapeutics, Ltd. · 2020 · 3 generations on2descendants
  • K203487Drakon and Sequre MicrocathetersAccurate Medical Therapeutics, Ltd. · 2020 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K915414Terumo Angiogtaphic CatheterTerumo Medical Corp.1992—
0 (this device)K981359GT LeggieroTerumo Medical Corp.1999—
+1K033583ProgreatTerumo Medical Corp.2003—
+2K173430SeQure® NF and SeQure® MicrocathetersAccurate Medical Therapeutics, Ltd.2018—
+2K033913ProgreatTerumo Medical Corp.2004—
+3K202797Drakon and Sequre MicrocathetersAccurate Medical Therapeutics, Ltd.2020—
+3K203487Drakon and Sequre MicrocathetersAccurate Medical Therapeutics, Ltd.2020—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
200410
201510
201610
201720
201820
202020
202110
202210
202310
202410
FIG. 1 — Lineage of K981359, 1992–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K915414Terumo Angiogtaphic Catheter
Summary page 1
…tasis. The Catheter should not be used in cerebral vessels. ' Note: This is the same intended use as the Terumo Angiographic Catheter (SP Catheter) cleared under 510(k) K915414. DESCRIPTION The GT Leggiero™ Catheter is a muitilayer single-lumen catheter 100-150cm in length with a maximum injection press…
Terumo Medical Corp.1992—

Also cleared against K915414: 4 other devices →

What descends from it? (14)

See all 14

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K033583ProgreatTerumo Medical Corp.200313

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K033583 (Terumo Medical Corp., 2003) has gone furthest, with 13 descendants of its own.
  • 4 other devices also cite its predicate K915414.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The GT Leggiero Catheter is intended for the infusion of contrast media into all peripheral vessels up to and including the cervical vessels, all vessels in the lower and upper extremities and all coronary vessels. The GT Leggiero Catheter is also intended for drug infusion in intra-arterial therapy and the infusion of embolic materials for hemostasis. The Catheter should not be used in cerebral vessels.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K981359: GT Leggiero.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K981359

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026