Startrack Infant Graphics Monitor

K983274510(k) TraditionalCleared Dec 9, 199883-day reviewClass II21 CFR 868.1850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nellcor Puritan Bennett, Inc. · BZK Spirometer, Monitoring (W/Wo Alarm)

Cleared on Dec 9, 1998 as substantially equivalent to K890724 (Bear Medical Systems, Inc., 1989) after an 83-day review. Its family tree reaches back 1 generation to 1989. 1 later device descends from it.

Decided
Dec 9, 1998
Review
83 days
Class
Class II
Product code
BZK
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K890724 (1989). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2005: 1 descendant clearedK890724 · Mofification Bear NVM-1 Neonatal Volume Monitor · Bear Medical Systems, Inc. · 19891990200020102020
Descendants, by generation 1 generation forward: 1 descendant K890724 · Mofification Bear NVM-1 Neonatal Volume Monitor · Bear Medical Systems, Inc. · 19890
  1. Root · 1 generation backK890724 Mofification Bear NVM-1 Neonatal Volume MonitorBear Medical Systems, Inc. · 1989
  2. This deviceK983274 Startrack Infant Graphics MonitorNellcor Puritan Bennett, Inc. · 1998
  3. Descendant · cites it directly · 0 of its ownK051279 Caldyne, Inc. Exhalometer EX100, Model EX100Caldyne, Inc. · 2005

Most influential descendants

Showing 1 of 1 · See all
  • K051279Caldyne, Inc. Exhalometer EX100, Model EX100Caldyne, Inc. · 2005 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K890724Mofification Bear NVM-1 Neonatal Volume MonitorBear Medical Systems, Inc.1989—
0 (this device)K983274Startrack Infant Graphics MonitorNellcor Puritan Bennett, Inc.1998—
+1K051279Caldyne, Inc. Exhalometer EX100, Model EX100Caldyne, Inc.2005—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
FIG. 1 — Lineage of K983274, 1989–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZK device

  1. #1 K260226 ElintMAX Respiratory Monitor (ElintMAX Monitor…score 19.5 · 26 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K890724Mofification Bear NVM-1 Neonatal Volume Monitor
Summary page 1
…nducted as well as in-vitro testing to confirm the accuracy of StarTrack. The predicate device is as follows: Bear Medical Systems Neonatal Volume Monitor, model NVM-1, K890724. Section 16.e Device Description The StarTrack Infant Graphics Monitor, StarTrack is contained in a rectangular metal enclosure…
Bear Medical Systems, Inc.1989—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K051279Caldyne, Inc. Exhalometer EX100, Model EX100Caldyne, Inc.20050

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K051279 (Caldyne, Inc., 2005) has gone furthest, with 0 descendants of its own.

How does its category compare?

All BZK devices

BZK Spirometer, Monitoring (W/Wo Alarm): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BZK

2in 2019

2008: 12009: 32011: 12012: 12013: 12017: 12018: 22019: 22026 (partial year): 1
2007high 3 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZK

71in 2009

2009: 71 days median
2007high 71 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZK

2in 2011

2011: 2
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BZK

2in 2020

2009: 12012: 12013: 732014: 312015: 122016: 12017: 12018: 12020: 2
2007high 73 (2013) · low 0 (2007)2025

MAUDE reports naming product code BZK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
200937101
20100—00
20111—20
20121—01
20131—073
20140—031
20150—012
20160—01
20171—01
20182—01
20192—00
20200—02
20210—00
20220—00
20230—00
20240—00
20250—00
20261—0—

What is it indicated for?

The StarTrack Infant Graphics Monitor’s intended use is the measurement and display of breathing flow, volume and pressure as delivered trough the patient's endotracheal tube. The intended patient population comprises neonatal and pediatric patients requiring an endotracheal tube <5.0mm I.D. and/or who do not exceed a peak breathing flow of 30 L/Min directly through the ET tube. The intended environments of use comprise Hospital, Hospital-type and…

Read the full statement (128 words)

The StarTrack Infant Graphics Monitor’s intended use is the measurement and display of breathing flow, volume and pressure as delivered trough the patient's endotracheal tube. The intended patient population comprises neonatal and pediatric patients requiring an endotracheal tube <5.0mm I.D. and/or who do not exceed a peak breathing flow of 30 L/Min directly through the ET tube. The intended environments of use comprise Hospital, Hospital-type and Intra-Hospital Transport environments. The device is for prescription use only. Hospital use typically covers such areas as general care floors, operating rooms, special procedure areas, intensive and critical care areas, within the hospital plus hospital-type facilities such as Surgicenters, Sub-acute Centers and Special Nursing Facilities, outside of the hospital. Intra-hospital transport includes transport with a patient within the hospital or hospital-type facility.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K983274: Startrack Infant Graphics Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K983274

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026