510(k) · Cleared
ClearedD.O.R.C. Harmony Total Vitrectomy System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dutch Ophthalmic USA, Inc. · HQE Instrument, Vitreous Aspiration And Cutting, Ac-Powered
Cleared on Mar 3, 1999 as substantially equivalent to K961310 (Storz Instrument Co., 1996) and 3 other predicates after a 126-day review. Its family tree reaches back 1 generation to 1993.
- Decided
- Mar 3, 1999
- Review
- 126 days
- Class
- Class II
- Product code
- HQE
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 1 generation to K924222 (1993). 4 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK924222 Mid Labs, Inc. Vit MateMedical Instrument Development Laboratories, Inc. · 1993
- This deviceK983797 D.O.R.C. Harmony Total Vitrectomy SystemDutch Ophthalmic USA, Inc. · 1999
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K924222 | Mid Labs, Inc. Vit Mate | Medical Instrument Development Laboratories, Inc. | 1993 | — |
| 0 (this device) | K983797 | D.O.R.C. Harmony Total Vitrectomy System | Dutch Ophthalmic USA, Inc. | 1999 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1996 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HQE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HQE device
- #1 K212763 UniVit HE, UniVit UHSscore 4.1 · 2 generations · no Class I recall
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K961310 | Storz Premiere II Microsurgical System (CX Series)Summary page 1…us Aspiration & Cutting Instrument (86HQE & 21CFR 886.4150) PREDICATE DEVICE/S Manufacturer Product Name 510(k) Number Alcon Surgical Accurus unknown Storz Millenium K961310 MID Labs SupraVit/VitMate K932669/K924222 Scieran Vit Commander K961738 DEVICE DESCRIPTION The D.O.R.C. Harmony Total Vitrect… | 1996 |
| * | K932669 | Supra-Vit (TM)Summary page 1…(86HQE & 21CFR 886.4150) PREDICATE DEVICE/S Manufacturer Product Name 510(k) Number Alcon Surgical Accurus unknown Storz Millenium K961310 MID Labs SupraVit/VitMate K932669/K924222 Scieran Vit Commander K961738 DEVICE DESCRIPTION The D.O.R.C. Harmony Total Vitrectomy System is an integrated system… | 1994 |
| * | K924222 | Mid Labs, Inc. Vit MateSummary page 1…21CFR 886.4150) PREDICATE DEVICE/S Manufacturer Product Name 510(k) Number Alcon Surgical Accurus unknown Storz Millenium K961310 MID Labs SupraVit/VitMate K932669/K924222 Scieran Vit Commander K961738 DEVICE DESCRIPTION The D.O.R.C. Harmony Total Vitrectomy System is an integrated system for post… | 1993 |
| * | K961738 | Vit Commander SystemSummary page 1…ICE/S Manufacturer Product Name 510(k) Number Alcon Surgical Accurus unknown Storz Millenium K961310 MID Labs SupraVit/VitMate K932669/K924222 Scieran Vit Commander K961738 DEVICE DESCRIPTION The D.O.R.C. Harmony Total Vitrectomy System is an integrated system for posterior segment eye surgery. It p… | 1996 |
| * | — | Accurus Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- 1 of the 4 ancestors has a recall of any class.
- 10 other devices also cite its predicate K961310.
How does its category compare?
All HQE devicesHQE Instrument, Vitreous Aspiration And Cutting, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HQE
1in 2022
2026 to Oct 25, outlined.
Median 510(k) review, days · HQE
Too few HQE 510(k)s in any year since 2007 to give a median.
Recalls per year · HQE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HQE
339in 2025
MAUDE reports naming product code HQE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 2 | 300 |
| 2008 | 0 | — | 0 | 65 |
| 2009 | 0 | — | 0 | 34 |
| 2010 | 0 | — | 11 | 27 |
| 2011 | 1 | — | 0 | 21 |
| 2012 | 2 | — | 0 | 34 |
| 2013 | 0 | — | 0 | 9 |
| 2014 | 1 | — | 0 | 9 |
| 2015 | 0 | — | 0 | 9 |
| 2016 | 1 | — | 4 | 10 |
| 2017 | 1 | — | 0 | 59 |
| 2018 | 0 | — | 0 | 309 |
| 2019 | 0 | — | 0 | 41 |
| 2020 | 0 | — | 0 | 30 |
| 2021 | 0 | — | 0 | 32 |
| 2022 | 1 | — | 0 | 46 |
| 2023 | 0 | — | 0 | 108 |
| 2024 | 0 | — | 0 | 105 |
| 2025 | 0 | — | 1 | 339 |
| 2026 | 0 | — | 3 | — |
What is it indicated for?
The D.O.R.C. Harmony Total vitrectomy system is a surgical system for ophthalmic surgery intended for use in surgery of the posterior segment (vitrectomy).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K983797 · printed Nov 4, 2026
Cite this page
510(k) Report. “K983797: D.O.R.C. Harmony Total Vitrectomy System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K983797
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026