510(k) · Cleared
ClearedModification of Depuy Ace Timax Medial Pilon Plate
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Depuy Ace Medical Co. · HSB Rod, Fixation, Intramedullary And Accessories
Cleared on Feb 1, 1999 after a 19-day review. The FDA summary names its predicate without a number. 221 later devices descend from it.
- Decided
- Feb 1, 1999
- Review
- 19 days
- Class
- Class II
- Product code
- HSB
- Recalls
- None
- Predicates
- 0
221 later devices descend from it, 3 citing it directly.
- This deviceK990120 Modification of Depuy Ace Timax Medial Pilon PlateDepuy Ace Medical Co. · 1999
- Descendant · cites it directly · 161 of its ownK031666 Arthrex Fiberwire Button Repair Kit, Model AR-8920DS/AR-8921DSArthrex, Inc. · 2003 · Recalled
- Descendant · 2 generations on · 143 of its ownK062747 Arthrex Retrobutton, 15MM, 60MM, Retrobutton, Long, 15MM, 60MMArthrex, Inc. · 2006
- Descendant · 2 generations on · 65 of its ownK100652 Acl TightropeArthrex, Inc. · 2010
- Descendant · cites it directly · 58 of its ownK072832 Anterolateral and Medial Locking Plating SystemDePuy Orthopaedics, Inc. · 2007 · Recalled
- Descendant · 2 generations on · 55 of its ownK092812 Synthes (Usa) 2.7MM/ 3.5MM LCP Anterolateral Distal Tibia PlatesSynthes (Usa) · 2010
Showing 5 of 221 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 221 · See all- K031666Arthrex Fiberwire Button Repair Kit, Model AR-8920DS/AR-8921DSArthrex, Inc. · 2003 · cites it directly161descendants
- K062747Arthrex Retrobutton, 15MM, 60MM, Retrobutton, Long, 15MM, 60MMArthrex, Inc. · 2006 · 2 generations on143descendants
- K100652Acl TightropeArthrex, Inc. · 2010 · 2 generations on65descendants
- K072832Anterolateral and Medial Locking Plating SystemDePuy Orthopaedics, Inc. · 2007 · cites it directly58descendants
- K092812Synthes (Usa) 2.7MM/ 3.5MM LCP Anterolateral Distal Tibia PlatesSynthes (Usa) · 2010 · 2 generations on55descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K990120 | Modification of Depuy Ace Timax Medial Pilon Plate | Depuy Ace Medical Co. | 1999 | — |
| +1 | K031666 | Arthrex Fiberwire Button Repair Kit, Model AR-8920DS/AR-8921DS | Arthrex, Inc. | 2003 | 1 |
| +2 | K062747 | Arthrex Retrobutton, 15MM, 60MM, Retrobutton, Long, 15MM, 60MM | Arthrex, Inc. | 2006 | — |
| +2 | K100652 | Acl Tightrope | Arthrex, Inc. | 2010 | — |
| +1 | K072832 | Anterolateral and Medial Locking Plating System | DePuy Orthopaedics, Inc. | 2007 | 2 |
| +2 | K092812 | Synthes (Usa) 2.7MM/ 3.5MM LCP Anterolateral Distal Tibia Plates | Synthes (Usa) | 2010 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2007 | 2 | 0 |
| 2008 | 1 | 0 |
| 2009 | 2 | 0 |
| 2010 | 2 | 0 |
| 2011 | 3 | 0 |
| 2012 | 3 | 0 |
| 2013 | 3 | 0 |
| 2014 | 11 | 0 |
| 2015 | 9 | 0 |
| 2016 | 8 | 0 |
| 2017 | 10 | 0 |
| 2018 | 5 | 0 |
| 2019 | 17 | 0 |
| 2020 | 16 | 0 |
| 2021 | 17 | 0 |
| 2022 | 13 | 0 |
| 2023 | 27 | 0 |
| 2024 | 27 | 0 |
| 2025 | 20 | 0 |
| 2026 | 22 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HSB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HSB device
- #1 K200869 Gamma3 Systemscore 19.8 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | DePuy ACE TiMAX™ Pilon Plate Named without a submission number |
What descends from it? (221)
See all 2213 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K031666 (Arthrex, Inc., 2003) has gone furthest, with 161 descendants of its own.
How does its category compare?
All HSB devicesHSB Rod, Fixation, Intramedullary And Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HSB
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HSB
106in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HSB
18in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HSB
2,911in 2025
MAUDE reports naming product code HSB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 8 | 68 | 0 | 162 |
| 2008 | 11 | 57 | 9 | 184 |
| 2009 | 18 | 86 | 81 | 334 |
| 2010 | 14 | 117 | 18 | 454 |
| 2011 | 16 | 78 | 2 | 662 |
| 2012 | 17 | 112 | 7 | 1,079 |
| 2013 | 18 | 105 | 14 | 1,773 |
| 2014 | 19 | 147 | 3 | 1,474 |
| 2015 | 22 | 111 | 3 | 1,671 |
| 2016 | 8 | 124 | 6 | 1,920 |
| 2017 | 23 | 119 | 66 | 1,447 |
| 2018 | 17 | 134 | 56 | 3,526 |
| 2019 | 13 | 132 | 6 | 2,517 |
| 2020 | 17 | 112 | 6 | 3,299 |
| 2021 | 10 | 94 | 2 | 4,111 |
| 2022 | 12 | 172 | 1 | 2,733 |
| 2023 | 11 | 162 | 1 | 2,219 |
| 2024 | 13 | 195 | 1 | 2,869 |
| 2025 | 15 | 106 | 18 | 2,911 |
| 2026 | 18 | 151 | 1 | — |
What is it indicated for?
Pilon fractures - distal tibial intra-articular fractures
High medial malleolar fractures
Low boot top type rotational distal extra-articular shaft fractures
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990120 · printed Nov 6, 2026
Cite this page
510(k) Report. “K990120: Modification of Depuy Ace Timax Medial Pilon Plate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K990120
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026