510(k) Report

510(k) · Cleared

Cleared

Nellcor Puritan Bennett Achieva Ventilator and Report Generator

K990177510(k) TraditionalCleared Nov 18, 1999303-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nellcor Puritan Bennett, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Nov 18, 1999 as substantially equivalent to K903010 (Aequitron Medical, Inc., 1990) and 1 other predicate after a 303-day review. Its family tree reaches back 1 generation to 1989. 3 later devices descend from it.

Decided
Nov 18, 1999
Review
303 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K894316 (1989). 2 ancestors in all. 3 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1990: 1 other ancestor2004: 2 descendants cleared2009: 1 descendant clearedK894316 · Amadeus Ventilator · Hamilton Medical, Inc. · 19891990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 1 descendant K894316 · Amadeus Ventilator · Hamilton Medical, Inc. · 19890
  1. Root · 1 generation backK894316 Amadeus VentilatorHamilton Medical, Inc. · 1989
  2. This deviceK990177 Nellcor Puritan Bennett Achieva Ventilator and Report GeneratorNellcor Puritan Bennett, Inc. · 1999
  3. Descendant · cites it directly · 1 of its ownK034032 PLV Continuum Ventilator, Model P2000Respironics California, Inc. · 2004
  4. Descendant · 2 generations on · 0 of its ownK081845 IVENT101Versamed Medical Systems, Inc. · 2009
  5. Descendant · cites it directly · 0 of its ownK040712 Air Safety Hepa, Model 3500Air Safety, Ltd. · 2004

Most influential descendants

Showing 3 of 3 · See all
  • K034032PLV Continuum Ventilator, Model P2000Respironics California, Inc. · 2004 · cites it directly1descendant
  • K081845IVENT101Versamed Medical Systems, Inc. · 2009 · 2 generations on0descendants
  • K040712Air Safety Hepa, Model 3500Air Safety, Ltd. · 2004 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K894316Amadeus VentilatorHamilton Medical, Inc.1989—
0 (this device)K990177Nellcor Puritan Bennett Achieva Ventilator and Report GeneratorNellcor Puritan Bennett, Inc.1999—
+1K034032PLV Continuum Ventilator, Model P2000Respironics California, Inc.2004—
+2K081845IVENT101Versamed Medical Systems, Inc.2009—
+1K040712Air Safety Hepa, Model 3500Air Safety, Ltd.2004—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200420
200910
FIG. 1 — Lineage of K990177, 1989–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CBK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K903010Continuous Volume Ventilator Model LP10
Summary page 1
…, Classification Number 73 CBK) Predicate Devices: The Achieva Ventilator is substantially equivalent to both the Nellcor Puritan Bennett Model LP10 Volume Ventilator (K903010) and the Hamilton Medical Amadeus Ventilator (K894316). Device Description: The Achieva Ventilator is a piston driven device wh…
Aequitron Medical, Inc.1990—
*K894316Amadeus Ventilator
Summary page 1
…he Achieva Ventilator is substantially equivalent to both the Nellcor Puritan Bennett Model LP10 Volume Ventilator (K903010) and the Hamilton Medical Amadeus Ventilator (K894316). Device Description: The Achieva Ventilator is a piston driven device which can deliver a wide range of volumes, inspiratory t…
Hamilton Medical, Inc.1989—

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K034032PLV Continuum Ventilator, Model P2000Respironics California, Inc.20041
K040712Air Safety Hepa, Model 3500Air Safety, Ltd.20040

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K034032 (Respironics California, Inc., 2004) has gone furthest, with 1 descendant of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The Achieva Ventilator is intended to provide ventilatory support for pediatric {Patients should weigh no less than 11 Ibs. (5 kg)} and adult patients who require positive pressure mechanical ventilation. The ventilator is for use in home, institutional, and portable settings. The Achieva is contraindicated for use with anesthetic gases. This device is intended to be used on the order, and under the supervision, of a physician. The Achieva Report…

Read the full statement (154 words)

The Achieva Ventilator is intended to provide ventilatory support for pediatric {Patients should weigh no less than 11 Ibs. (5 kg)} and adult patients who require positive pressure mechanical ventilation. The ventilator is for use in home, institutional, and portable settings. The Achieva is contraindicated for use with anesthetic gases. This device is intended to be used on the order, and under the supervision, of a physician.

The Achieva Report Generator is a management and information tool, to aid in the care of patients requiring ventilatory support. The information displayed by the Report Generator software is intended to be used by healthcare professionals to supplement data obtained using established clinical procedures. The Achieva Report Generator allows users to download, view, and print ventilator performance data that have been stored in the ventilator’s internal memory. Achieva Report Generator users can also capture and display a snapshot of real-time waveform data (pressure, peak flow, and volume).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K990177: Nellcor Puritan Bennett Achieva Ventilator and Report Generator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K990177

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026