510(k) · Cleared
ClearedCobe VVR 4000 Filtered Hardshell Venous Reservoir
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Cobe Cardiovascular, Inc. · DTN Reservoir, Blood, Cardiopulmonary Bypass
Cleared on May 25, 1999 as substantially equivalent to K984456 (Cobe Cardiovascular, Inc., 1999) after a 120-day review. Its family tree reaches back 2 generations to 1997.
- Decided
- May 25, 1999
- Review
- 120 days
- Class
- Class II
- Product code
- DTN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K971669 (1997). No later device cites it as a predicate yet.
- Root · 2 generations backK971669 Cobe HVR 4000 Filtered and Nonfiltered Hardshell Venous ReservoirCobe Cardiovascular, Inc. · 1997
- 1 generation backK984456 Cobe HVR 4000 Filtered Hardshell Venous ReservoirCobe Cardiovascular, Inc. · 1999
- This deviceK990239 Cobe VVR 4000 Filtered Hardshell Venous ReservoirCobe Cardiovascular, Inc. · 1999
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K971669 | Cobe HVR 4000 Filtered and Nonfiltered Hardshell Venous Reservoir | Cobe Cardiovascular, Inc. | 1997 | — |
| −1 | K984456 | Cobe HVR 4000 Filtered Hardshell Venous Reservoir | Cobe Cardiovascular, Inc. | 1999 | — |
| 0 (this device) | K990239 | Cobe VVR 4000 Filtered Hardshell Venous Reservoir | Cobe Cardiovascular, Inc. | 1999 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DTN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DTN device
- #1 K251783 Inspire HCR and HCR DUAL cardiotomy reservoirsscore 12.3 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K984456 | Cobe HVR 4000 Filtered Hardshell Venous ReservoirSummary page 2…RISON The COBE® VVR 4000™ Filtered Hardshell Venous Reservoir is substantially equivalent to the currently marketed COBE® HVR™ 4000 Filtered Hardshell Venous Reservoir (K984456). The two devices are identical except that the COBE® VVR 4000™ Filtered Hardshell Venous Reservoir has a gasketed lid joint, ven… | 1999 |
| * | — | Baxter/Bentley BMR-4500G Filtered Venous Reservoir Named without a submission number | |
| * | — | Baxter/Bentley HSR-4000 Filtered Venous Reservoir Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 2 years and passes through 1 company; a new generation was cleared every 1.5 years on median.
- None of the 2 ancestors has a recall.
How does its category compare?
All DTN devicesDTN Reservoir, Blood, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DTN
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DTN
38in 2014
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DTN
2in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DTN
8in 2025
MAUDE reports naming product code DTN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 1 | 10 |
| 2008 | 1 | — | 1 | 8 |
| 2009 | 7 | 211 | 1 | 10 |
| 2010 | 1 | — | 0 | 18 |
| 2011 | 2 | — | 1 | 10 |
| 2012 | 0 | — | 0 | 17 |
| 2013 | 4 | 79 | 0 | 47 |
| 2014 | 3 | 38 | 0 | 52 |
| 2015 | 2 | — | 0 | 27 |
| 2016 | 0 | — | 1 | 6 |
| 2017 | 2 | — | 1 | 3 |
| 2018 | 0 | — | 2 | 4 |
| 2019 | 0 | — | 0 | 11 |
| 2020 | 0 | — | 0 | 6 |
| 2021 | 0 | — | 0 | 12 |
| 2022 | 0 | — | 0 | 7 |
| 2023 | 1 | — | 0 | 8 |
| 2024 | 2 | — | 0 | 10 |
| 2025 | 1 | — | 0 | 8 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The COBE® VVR 4000™ Filtered Hardshell Venous Reservoir is intended to be used in adult surgical procedures requiring cardiopulmonary bypass for periods of up to six hours, and for postoperative chest drainage collection and autotransfusion.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990239 · printed Nov 6, 2026
Cite this page
510(k) Report. “K990239: Cobe VVR 4000 Filtered Hardshell Venous Reservoir.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K990239
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026