Soring GMBH, Sonoca 300

K992026510(k) TraditionalCleared Sep 23, 199999-day reviewClass II21 CFR 878.4780

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Soring GmbH Medizintechnik · BTA Pump, Portable, Aspiration (Manual Or Powered)

Cleared on Sep 23, 1999 as substantially equivalent to K942095 (Holl Meditronics, Inc., 1994) after a 99-day review. Its family tree reaches back 1 generation to 1994. 11 later devices descend from it.

Decided
Sep 23, 1999
Review
99 days
Class
Class II
Product code
BTA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K942095 (1994). 11 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2001: 1 descendant cleared2005: 1 descendant cleared2007: 1 descendant cleared2008: 1 descendant cleared2010: 1 descendant cleared2014: 1 descendant cleared2011: 1 descendant cleared2009: 1 descendant cleared2012: 1 descendant cleared2013: 2 descendants clearedK942095 · Sonoca Iii · Holl Meditronics, Inc. · 19941990200020102020
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 4 descendants4 generations forward: 2 descendants K942095 · Sonoca Iii · Holl Meditronics, Inc. · 19940
  1. Root · 1 generation backK942095 Sonoca IiiHoll Meditronics, Inc. · 1994
  2. This deviceK992026 Soring GMBH, Sonoca 300Soring GmbH Medizintechnik · 1999
  3. Descendant · cites it directly · 6 of its ownK012753 Soring GMBH Sonoca 180/190Soring GmbH Medizintechnik · 2001
  4. Descendant · 2 generations on · 5 of its ownK062544 AR1000 Ultrasonic Wound Therapy SystemArobella Medical, LLC · 2007 · Recalled
  5. Descendant · cites it directly · 3 of its ownK052183 Soring GMBH Sonoca LipoSoring GmbH Medizintechnik · 2005
  6. Descendant · 3 generations on · 2 of its ownK112782 Misonix Sonicone (R) Ultrasonic Wound Care System and AccessoriesMisonix, Inc. · 2011
  7. Descendant · 2 generations on · 2 of its ownK092066 Phaser Lipoplasty System (Dur-01), Phaser Disposable Kit (Dis-01)…Andrew Technologies, LLC · 2010

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

2001: 12005: 12007: 12008: 12009: 12010: 12011: 12012: 12013: 22014: 1
2001high 2 (2013) · low 0 (2002)2026

Most influential descendants

Showing 5 of 11 · See all
  • K012753Soring GMBH Sonoca 180/190Soring GmbH Medizintechnik · 2001 · cites it directly6descendants
  • K062544AR1000 Ultrasonic Wound Therapy SystemArobella Medical, LLC · 2007 · 2 generations on5descendants
  • K052183Soring GMBH Sonoca LipoSoring GmbH Medizintechnik · 2005 · cites it directly3descendants
  • K112782Misonix Sonicone (R) Ultrasonic Wound Care System and AccessoriesMisonix, Inc. · 2011 · 3 generations on2descendants
  • K092066Phaser Lipoplasty System (Dur-01), Phaser Disposable Kit (Dis-01), Phaser Waste…Andrew Technologies, LLC · 2010 · 2 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K942095Sonoca IiiHoll Meditronics, Inc.1994—
0 (this device)K992026Soring GMBH, Sonoca 300Soring GmbH Medizintechnik1999—
+1K012753Soring GMBH Sonoca 180/190Soring GmbH Medizintechnik2001—
+2K062544AR1000 Ultrasonic Wound Therapy SystemArobella Medical, LLC20071
+1K052183Soring GMBH Sonoca LipoSoring GmbH Medizintechnik2005—
+3K112782Misonix Sonicone (R) Ultrasonic Wound Care System and AccessoriesMisonix, Inc.2011—
+2K092066Phaser Lipoplasty System (Dur-01), Phaser Disposable Kit (Dis-01), Phaser…Andrew Technologies, LLC2010—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200110
200510
200710
200810
200910
201010
201110
201210
201320
201410
FIG. 1 — Lineage of K992026, 1994–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BTA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTA device

  1. #1 K222547 Electric nasal aspiratorscore 20.7 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K942095Sonoca Iii
Summary page 1
…e Name: Sonoca 300 Common Name: Instrument, Ultrasonic Surgical Classification Name: General & Plastic Surgery Predicate Device: Applicant: Soéring GmbH 510(k) Number: K942095 Device: Sonoca lli Device Description: SONOCA 300 is an upgraded version of the SONOCA Il having K9942095. During the use of an…
Holl Meditronics, Inc.1994—

What descends from it? (11)

See all 11

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K012753Soring GMBH Sonoca 180/190Soring GmbH Medizintechnik20016
K052183Soring GMBH Sonoca LipoSoring GmbH Medizintechnik20053

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K012753 (Soring GmbH Medizintechnik, 2001) has gone furthest, with 6 descendants of its own.

How does its category compare?

All BTA devices

BTA Pump, Portable, Aspiration (Manual Or Powered): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BTA

7so far in 2026, the most since 2007

2007: 12008: 32009: 22010: 22011: 12012: 12013: 32014: 32016: 32017: 12018: 42020: 12021: 12022: 32023: 42024: 52025: 62026 (partial year): 7
2007high 7 (2026) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTA

87in 2025

2008: 135 days median2013: 45 days median2014: 91 days median2016: 149 days median2018: 125 days median2022: 58 days median2023: 265 days median2024: 131 days median2025: 87 days median2026 (partial year): 89 days median
2007high 265 (2023) · low 45 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTA

1in 2021

2007: 12008: 32010: 32021: 1
2007high 3 (2008) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BTA

13in 2025

2007: 132008: 52009: 142010: 1782011: 622012: 472013: 182014: 3992015: 152016: 252017: 42018: 172019: 142020: 102021: 92022: 72023: 82024: 132025: 13
2007high 399 (2014) · low 4 (2017)2025

MAUDE reports naming product code BTA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—113
2008313535
20092—014
20102—3178
20111—062
20121—047
2013345018
20143910399
20150—015
20163149025
20171—04
20184125017
20190—014
20201—010
20211—19
202235807
2023426508
20245131013
2025687013
20267890—

What is it indicated for?

The SONOCA 300 is an instrument intended for selected ultrasound dissection, fragmenting, emulsifying, and aspiration of human tissue and adjunctive irrigation and suction at the operation site during multi-medical discipline surgery including: General Surgery, NE, PED, Thoracic, UR, and GI modalities but not including CV, Ent, Ortho or suction Lipectomy.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992026: Soring GMBH, Sonoca 300.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K992026

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026