510(k) Report

510(k) · Cleared

Recalled · 2004

Wallstent Tracheobronchial Endoprosthesis and Unistep Plus Delivery System

K992510510(k) TraditionalCleared Nov 18, 1999114-day reviewClass II21 CFR 878.3720Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corp · JCT Prosthesis, Tracheal, Expandable

Cleared on Nov 18, 1999 as substantially equivalent to K964121 (Boston Scientific Scimed, Inc., 1996) after a 114-day review. Its family tree reaches back 4 generations to 1992. 1 later device descends from it. It has been recalled once.

Decided
Nov 18, 1999
Review
114 days
Class
Class II
Product code
JCT
Recalls
1
Predicates
1

Its longest line of descent runs back 4 generations to K923119 (1992). 5 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 4 generations backK923119 Wallstent Esophageal ProthesisSchneider U.S. Stent Div. · 1992
  2. 3 generations backK945494 Wallstent (R) Tracheobronchial EndoprosthesisBoston Scientific Scimed, Inc. · 1995 · Recalled
  3. 2 generations backK961296 Wallstent Tracheobronchial EndoprosthesisBoston Scientific Scimed, Inc. · 1996 · Recalled
  4. 1 generation backK964121 Wallstent Tracheobronchial EndoprosthesisBoston Scientific Scimed, Inc. · 1996 · Recalled
  5. This deviceK992510 Wallstent Tracheobronchial Endoprosthesis and Unistep Plus Delivery…Boston Scientific Corp · 1999
  6. Descendant · cites it directly · 0 of its ownK152842 Wallstent RP Endoprosthesis Tracheobronchial, Wallstent…Boston Scientific Corporation · 2016 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K152842Wallstent RP Endoprosthesis Tracheobronchial, Wallstent Endoprosthesis TracheobronchialBoston Scientific Corporation · 2016 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K923119Wallstent Esophageal ProthesisSchneider U.S. Stent Div.1992—
−3K945494Wallstent (R) Tracheobronchial EndoprosthesisBoston Scientific Scimed, Inc.19951
−2K961296Wallstent Tracheobronchial EndoprosthesisBoston Scientific Scimed, Inc.19961
−1K964121Wallstent Tracheobronchial EndoprosthesisBoston Scientific Scimed, Inc.19961
0 (this device)K992510Wallstent Tracheobronchial Endoprosthesis and Unistep Plus Delivery SystemBoston Scientific Corp1999—
+1K152842Wallstent RP Endoprosthesis Tracheobronchial, Wallstent Endoprosthesis…Boston Scientific Corporation20165

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
FIG. 1 — Lineage of K992510, 1992–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JCT device

  1. #1 K230269 Ultraflex™ Tracheobronchial Stent Systemscore 8.1 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K964121Wallstent Tracheobronchial Endoprosthesis
Summary page 4
…ly 26, 1999 July 14, 2006 WALLSTENT® Tracheobronchial Endoprosthesis with Unistep™ Plus Delivery System Tracheal Endoprosthesis JCT Class lil, 21 CFR Part 878.3720 K964121 December 04, 1996 WALLSTENT® Tracheobronchial Endoprosthesis The WALLSTENT® Tracheobronchial Endoprosthesis is a self-expandin…
Boston Scientific Scimed, Inc.19961

Also cleared against K964121: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K152842Wallstent RP Endoprosthesis Tracheobronchial, Wallstent Endoprosthesis TracheobronchialBoston Scientific Corporation20160

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 9, 2004Not classifiedZ-1340-04OtherSpecific lots of the WALLSTENT Endoprosthesis with UNISTEP Plus Delivery System were packaged without one of the three required directions for use.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 2.5 years on median.
  • 3 of the 5 ancestors have a recall of any class.
  • Of its descendants, K152842 (Boston Scientific Corporation, 2016) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K964121.

How does its category compare?

All JCT devices

JCT Prosthesis, Tracheal, Expandable: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JCT

1in 2023

2007: 22008: 12009: 12012: 12014: 32016: 12018: 12020: 12021: 22022: 12023: 1
2007high 3 (2014) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JCT

234in 2014

2014: 234 days median
2007high 234 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JCT

2in 2011

2010: 462011: 2
2007high 46 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JCT

50in 2025

2007: 1502008: 1432009: 1632010: 1472011: 952012: 1092013: 2382014: 1682015: 2512016: 2172017: 1092018: 1222019: 1062020: 1202021: 1062022: 612023: 1102024: 742025: 50
2007high 251 (2015) · low 50 (2025)2025

MAUDE reports naming product code JCT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—0150
20081—0143
20091—0163
20100—46147
20110—295
20121—0109
20130—0238
201432340168
20150—0251
20161—0217
20170—0109
20181—0122
20190—0106
20201—0120
20212—0106
20221—061
20231—0110
20240—074
20250—050
20260—0—

What is it indicated for?

The WALLSTENT® Tracheobronchial Endoprosthesis is indicated for use in the treatment of tracheobronchial strictures produced by malignant neoplasms.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992510: Wallstent Tracheobronchial Endoprosthesis and Unistep Plus Delivery System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K992510

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026