510(k) Report

510(k) · Cleared

Cleared

Belmont Fluid Management System (FMS2000)

K992672510(k) SpecialCleared Aug 24, 199914-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Belmont Instrument Corp. · FRN Pump, Infusion

Cleared on Aug 24, 1999 as substantially equivalent to K972284 (Belmont Instrument Corp., 1997) after a 14-day review. Its family tree reaches back 2 generations to 1985. 1 of the 6 devices in its family, counting itself, has a Class I recall. 3 later devices descend from it.

Decided
Aug 24, 1999
Review
14 days
Class
Class II
Product code
FRN
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K852645 (1985). 3 later devices descend from it, 2 citing it directly. 1 of the 6 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2006: 1 descendant cleared, 1 with a Class I recall12003: 1 descendant cleared2022: 1 descendant clearedK852645 · Fluid Management System · Haemonetics Corp. · 1985K972284 · Fluid Management System · Belmont Instrument Corp. · 1997 · recalled1990200020102020
Descendants, by generation 1 generation forward: 2 descendants, 1 with a Class I recall12 generations forward: 1 descendant K972284 · Fluid Management System · Belmont Instrument Corp. · 1997 · recalledK852645 · Fluid Management System · Haemonetics Corp. · 19850
  1. Root · 2 generations backK852645 Fluid Management SystemHaemonetics Corp. · 1985
  2. 1 generation backK972284 Fluid Management SystemBelmont Instrument Corp. · 1997 · Recalled
  3. This deviceK992672 Belmont Fluid Management System (FMS2000)Belmont Instrument Corp. · 1999
  4. Descendant · cites it directly · 2 of its ownK032778 Large Volume Fluid ReservoirBelmont Instrument Corp. · 2003
  5. Descendant · cites it directly · 1 of its ownK052055 Smisson-Cartledge Thermal Infusion System, Model Tis-1200Smisson-Cartledge Biomedical, LLC · 2006 · Recalled (Class I)
  6. Descendant · 2 generations on · 0 of its ownK202461 ThermaCor 1200 Disposable Sets for the ThermaCor 1200 Rapid Thermal…Smisson-Cartledge Biomedical, LLC · 2022

Class I recalls in this family

Most influential descendants

Showing 3 of 3 · See all
  • K032778Large Volume Fluid ReservoirBelmont Instrument Corp. · 2003 · cites it directly2descendants
  • K052055Smisson-Cartledge Thermal Infusion System, Model Tis-1200Smisson-Cartledge Biomedical, LLC · 2006 · cites it directly1descendant
  • K202461ThermaCor 1200 Disposable Sets for the ThermaCor 1200 Rapid Thermal Infusion SystemSmisson-Cartledge Biomedical, LLC · 2022 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K852645Fluid Management SystemHaemonetics Corp.1985—
−1K972284Fluid Management SystemBelmont Instrument Corp.19971
0 (this device)K992672Belmont Fluid Management System (FMS2000)Belmont Instrument Corp.1999—
+1K032778Large Volume Fluid ReservoirBelmont Instrument Corp.2003—
+1K052055Smisson-Cartledge Thermal Infusion System, Model Tis-1200Smisson-Cartledge Biomedical, LLC2006Class I
+2K202461ThermaCor 1200 Disposable Sets for the ThermaCor 1200 Rapid Thermal Infusion…Smisson-Cartledge Biomedical, LLC2022—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
200611
202210
FIG. 1 — Lineage of K992672, 1985–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K972284Fluid Management System
Summary page 1
…luid Management Disposable Set System is substantially equivalent to the Belmont Fluid Management Disposable Set System, which was the subject of Premarket Notification #K972284 submitted in June 1997. Brief Description of the Device (Unchanged by the Modification): The Belmont Fluid Management System (SZ…
Belmont Instrument Corp.19971

Also cleared against K972284: 5 other devices →

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K032778Large Volume Fluid ReservoirBelmont Instrument Corp.20032
K052055Smisson-Cartledge Thermal Infusion System, Model Tis-1200 Class ISmisson-Cartledge Biomedical, LLC20061

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K052055Smisson-Cartledge Thermal Infusion System, Model Tis-1200Smisson-Cartledge Biomedical, LLC · 2006 · Cites it directly · ◆ in the 2006 descendants bar of FIG. 13 Class I recalls

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 11.9 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K032778 (Belmont Instrument Corp., 2003) has gone furthest, with 2 descendants of its own.
  • 5 other devices also cite its predicate K972284.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

A Infusion of crystalloid, colloid, or blood product, including packed red blood cells, as volume replacement for patients suffering from blood loss due to trauma or surgery.

B. Infusion of warmed fluid to rewarm patients after surgery or for hypothermia.

C. Infusion of warmed fluid for irrigation in urology procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992672: Belmont Fluid Management System (FMS2000).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992672

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026