K993100510(k) SpecialCleared Oct 6, 199920-day reviewClass II21 CFR 862.3610

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Redwood Biotech, Inc. · DJC Thin Layer Chromatography, Methamphetamine

Cleared on Oct 6, 1999 after a 20-day review. The FDA summary names its predicate without a number.

Decided
Oct 6, 1999
Review
20 days
Class
Class II
Product code
DJC
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K993100Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DJC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DJC device

  1. #1 K253705 Healgen® Accurate Oral Fluid Drug Testscore 12.2 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Redi-THC
Named without a submission number
—
*—Redi-PCP
Named without a submission number
—
*—Redi-Cocaine
Named without a submission number
—
*—Redi-Opiates
Named without a submission number
—
*—Redi-Methamphetamine
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All DJC devices

DJC Thin Layer Chromatography, Methamphetamine: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DJC

1in 2025

2008: 12013: 12016: 12018: 32025: 12026 (partial year): 1
2007high 3 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DJC

258in 2018

2018: 258 days median
2007high 258 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DJC

No recall names DJC since 2007.

Adverse event reports per year · DJC

2in 2018

2017: 12018: 2
2007high 2 (2018) · low 0 (2007)2025

MAUDE reports naming product code DJC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20090—00
20100—00
20110—00
20120—00
20131—00
20140—00
20150—00
20161—00
20170—01
2018325802
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20251—00
20261—0—

What is it indicated for?

The Redi-Screen is a qualitative, one step, immunochromatographic competitive assay used to screen human urine for the presence of THC, Phencyclidine, Opiates, Cocaine and Methamphetamine at the following cut off concentrations;

THC 50ng/mL

PCP 25ng/mL

Opiates 300ng/mL

Cocaine 300ng/mL

Methamphetamine 1,000ng/mL

The test is qualitative and provides only a preliminary analytical result, which must be confirmed by an alternate methodology preferably, GC/MS.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K993100: Redi-Screen.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K993100

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026